[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100666325":3},{"organization":4,"outcomesModule":7,"designInfo":163,"detailedDescription":162,"studyPopulation":162,"armGroups":169,"interventions":186,"overallOfficials":212,"centralContacts":217,"locations":223,"responsibleParty":402,"collaborators":404,"id":408,"slug":409,"hasResults":410,"nctId":411,"briefTitle":412,"officialTitle":413,"acronym":414,"eligibilityCriteria":415,"healthyVolunteers":410,"sex":416,"minAge":417,"maxAge":162,"enrollmentInfo":418,"targetDuration":162,"studyType":421,"phases":422,"briefSummary":424,"conditions":425,"keywords":162,"overallStatus":256,"whyStopped":162,"lastUpdateSubmitDate":427,"lastUpdatePostDateStruct":428,"startDateStruct":431,"completionDateStruct":433,"leadSponsor":435,"locationsCount":436},{"fullName":5,"class":6},"Sigvaris France","INDUSTRY",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":162},[9],{"measure":10,"description":11,"timeFrame":12},"Rate of complete healing at 12 weeks","Achieving complete healing of the UVJ wound for the patient within a maximum period of 12 weeks. Complete healing will be defined as 100 per cent re-epithelialisation of the gingival margin with no exudate, as confirmed by the investigator. The wound surface area will be measured in a standardized manner using Pixacare® software (AI module) based on a photograph of the wound taken directly in the application.","12 weeks",[14,18,21,24,27,30,33,36,39,42,45,48,51,54,57,60,63,66,69,72,75,78,81,84,87,90,93,96,99,102,105,108,111,114,117,120,123,126,129,132,135,138,141,144,147,150,153,156,159],{"measure":15,"description":16,"timeFrame":17},"Absolute reduction in wound surface area","The absolute reduction in wound surface area is defined as the difference between the area of the wound of interest at the time of inclusion (in cm²) and the area of the same wound of interest at the time point under consideration (in cm²).\n\nThe wound surface area will be measured in a standardized manner using Pixacare® software (AI module) based on a photograph of the wound taken directly in the application.","From enrollment through study completion, an average of 3 months",{"measure":19,"description":20,"timeFrame":17},"Relative reduction in wound surface area","The relative reduction in wound surface area is calculated by dividing the absolute reduction in wound surface area by the initial surface area (in cm²) of the wound in question. The relative reduction in wound surface area is expressed as a percentage.\n\nThe wound surface area will be measured in a standardized manner using Pixacare® software (AI module) based on a photograph of the wound taken directly in the application.",{"measure":22,"description":23,"timeFrame":17},"Healing time","The healing time (in days) will be defined as the period between the date of enrolment and the date of complete healing in patients whose wounds have healed completely (100% of re-epithelialisation) during the 12-week follow-up period.\n\nThe wound surface area will be measured in a standardized manner using Pixacare® software (AI module) based on a photograph of the wound taken directly in the application.",{"measure":25,"description":26,"timeFrame":17},"Description of wound surface","The assessment of wound surface in cm² will be carried out in a standardised manner using the Pixacare® software (AI module), based on a photograph of the wound taken directly within the application.",{"measure":28,"description":29,"timeFrame":17},"Description of wound length","The assessment of wound length in cm will be carried out in a standardised manner using the Pixacare® software (AI module), based on a photograph of the wound taken directly within the application.",{"measure":31,"description":32,"timeFrame":17},"Description of wound width","The assessment of wound width in cm will be carried out in a standardised manner using the Pixacare® software (AI module), based on a photograph of the wound taken directly within the application.",{"measure":34,"description":35,"timeFrame":17},"Description of wound depth","The assessment of wound depth in cm will be carried out in a standardised manner using the Pixacare® software (AI module), based on a photograph of the wound taken directly within the application.",{"measure":37,"description":38,"timeFrame":17},"Description of wound percentage of fibrin","The assessment of wound percentage of fibrin will be carried out in a standardised manner using the Pixacare® software (AI module), based on a photograph of the wound taken directly within the application.",{"measure":40,"description":41,"timeFrame":17},"Description of wound percentage of granulation tissue","The assessment of wound percentage of granulation tissue will be carried out in a standardised manner using the Pixacare® software (AI module), based on a photograph of the wound taken directly within the application.",{"measure":43,"description":44,"timeFrame":17},"Description of appearance of the skin","The appearance of the skin surrounding the lesion will be assessed using a nominal categorical variable.",{"measure":46,"description":47,"timeFrame":17},"Description of the level of exudate","The level of exudate will be measured using a 4-point Likert scale (ordinal categorical variable).",{"measure":49,"description":50,"timeFrame":17},"Incidence of defined complications","The presence of haemorrhage, local infection, necrosis will be assessed using a binary criterion.",{"measure":52,"description":53,"timeFrame":17},"Incidence of edema in the lower limbs","The presence of oedema (binary criterion) will be assessed clinically by checking for the 'cup sign'.\n\nThe extent of any oedema will be characterised by measuring the circumference of the ankle (in cm) and that of the calf at its thickest point (in cm).",{"measure":55,"description":56,"timeFrame":17},"Overall pain","Overall pain will be measured using a simple numerical rating scale (NRS) ranging from 0 to 10. A score of 0 corresponds to no pain, and a score of 10 to the maximum, unbearable pain.",{"measure":58,"description":59,"timeFrame":17},"Pain at the wound site","Pain at the wound site will be measured using a simple numerical rating scale (NRS) ranging from 0 to 10. A score of 0 corresponds to no pain, and a score of 10 to the maximum, unbearable pain.",{"measure":61,"description":62,"timeFrame":17},"Incidence of defined local side effects","The following local adverse effects, resulting from the use of the compression device under investigation, will be assessed:\n\n* Itching, measured using a 4-point Likert scale (ordinal categorical variable)\n* Sensation of heat, measured using a 4-point Likert scale (ordinal categorical variable)\n* Condition of the skin beneath the compression device (nominal categorical variable)",{"measure":64,"description":65,"timeFrame":17},"Pain when the compression device is fitted","Pain experienced whilst the compression device is being fitted will be measured using a simple numerical rating scale (NSR) ranging from 0 to 10. A score of 0 corresponds to no pain, and a score of 10 to maximum, unbearable pain.",{"measure":67,"description":68,"timeFrame":17},"Pain associated with wearing the compression device","Pain associated with wearing the compression device will be measured using a simple numerical rating scale (NRS) ranging from 0 to 10. A score of 0 corresponds to no pain, and a score of 10 to maximum, unbearable pain.",{"measure":70,"description":71,"timeFrame":17},"Rate of incidents relating to the compression device","Any malfunction or fault in the compression device used will be recorded (binary criteria).",{"measure":73,"description":74,"timeFrame":17},"Score of ease of application","The ease of fitting the compression device (application of the device) will be measured using a 4-point Likert scale (ordinal categorical variable).",{"measure":76,"description":77,"timeFrame":17},"Average time taken to apply the compression device","The average time, in minutes, taken to fit the compression device will be described.",{"measure":79,"description":80,"timeFrame":17},"Score of ease of removal","The ease of removing the compression device will be measured using a 4-point Likert scale (ordinal categorical variable)",{"measure":82,"description":83,"timeFrame":17},"Average time taken to remove the compression device","The average time, in minutes, taken to remove the compression device will be described.",{"measure":85,"description":86,"timeFrame":17},"Score of ease of use of the compression device","The ease of use of the compression device will be measured using a 4-point Likert scale (ordinal categorical variable)",{"measure":88,"description":89,"timeFrame":17},"Average number of days the device is worn per week","The average number of days the device is worn per week will be described",{"measure":91,"description":92,"timeFrame":17},"Average number of hours the device is worn per day","The average number of hours the device is worn per day will be described",{"measure":94,"description":95,"timeFrame":17},"Average number of hours the device is worn per night","The average number of hours the device is worn per night will be described",{"measure":97,"description":98,"timeFrame":17},"Rate of compliance for correct positioning of the device","Compliance with the criteria for correct positioning (binary criteria): 5 criteria for the experimental group (ankle, heel, upper edge of the protective sock, all Velcro fastenings, all Accutab devices) and 6 criteria for the control group (ankle, heel, upper edge of the straps, lower edge of the straps, slippage, calibration)",{"measure":100,"description":101,"timeFrame":17},"Score of patient's ability to walk whilst wearing the compression device","The patient's ability to walk whilst wearing the compression device will be measured using a 4-point Likert scale (ordinal categorical variable)",{"measure":103,"description":104,"timeFrame":17},"Score of patient's ankle range of motion with the compression device","The patient's ankle range of motion with the compression device in place will be measured using a 4-point Likert scale (ordinal categorical variable)",{"measure":106,"description":107,"timeFrame":17},"Score of the compression device's ability to conform to the leg","The compression device's ability to conform to the leg will be measured using a 4-point Likert scale (ordinal categorical variable)",{"measure":109,"description":110,"timeFrame":17},"Score of the ease with which the patient could put on their shoes","The ease with which the patient could put on their shoes whilst wearing the compression device will be measured using a 4-point Likert scale (ordinal categorical variable)",{"measure":112,"description":113,"timeFrame":17},"Score of long-term retention of the compression device","The long-term retention of the compression device wiil be measured using a 4-point Likert scale (ordinal categorical variable)",{"measure":115,"description":116,"timeFrame":17},"Score of system acceptability","Patient acceptance of the compression device will be measured using a 4-point Likert scale (ordinal categorical variable).",{"measure":118,"description":119,"timeFrame":17},"Score of overall comfort","The overall comfort when using the compression device will be measured using a simple numerical scale (ENS) ranging from 0 to 10. A score of 0 corresponds to total discomfort when using the compression device, and a score of 10 to perfect comfort.",{"measure":121,"description":122,"timeFrame":17},"Score of overall quality of life through EQ-5D-5L questionnaire","The first section of the questionnaire explores five dimensions: mobility, independence, everyday activities, pain and discomfort, and anxiety and depression. Each dimension is assessed using a 5-point Likert scale (ranging from 1 'no problem' to 5 'extreme problem'), which provides a profile of perceived health status. This profile is then converted into a quality of life score ranging from 0 ('a state equivalent to death') to 1 ('perfect health'), using a weighting grid specific to the country in which the questionnaire is administered.\n\nThe second part of the questionnaire is a visual analogue scale (VAS) ranging from 0 ('the worst health state imaginable') to 100 ('the best health state imaginable'), on which the patient indicates their overall perception of their health at the time of completing the questionnaire ('today').",{"measure":124,"description":125,"timeFrame":17},"Score of quality of life specific to chronic wounds through Wound-QoL-14 questionnaire","This questionnaire comprises 14 items, grouped into three dimensions: physical symptoms (pain, odour, exudate, sleep), psychological impact (mood, frustration, anxiety, fear of the condition's progression), and impact on daily life (mobility, daily activities, leisure, interactions with others, independence). Each item is rated using a 5-point Likert scale, ranging from 0 ('not at all') to 4 ('extremely'), depending on the intensity or frequency of the symptom experienced over the past week.\n\nThe overall score is calculated by taking the average of the 14 items, resulting in a total score ranging from 0 to 4, where a higher score reflects a greater impairment to quality of life.",{"measure":127,"description":128,"timeFrame":17},"Score of Patient clinical Global Impression of Change","The PGIC takes the form of a 7-point Likert scale, ranging from 1 ('very much improved') to 7 ('very much worsened'), with 4 ('no change') in between.",{"measure":130,"description":131,"timeFrame":17},"Score of overall physician satisfaction","The doctor's overall satisfaction with the use of the compression device will be measured using a simple numerical scale (SNS) ranging from 0 to 10. A score of 0 corresponds to complete dissatisfaction with the use of the compression device, and a score of 10 to complete satisfaction.",{"measure":133,"description":134,"timeFrame":17},"Score of overall home nurse satisfaction","The overall satisfaction of the nurses with the use of the compression device will be measured using a simple numerical scale (SNS) ranging from 0 to 10. A score of 0 corresponds to complete dissatisfaction with the use of the compression device, and a score of 10 to complete satisfaction.",{"measure":136,"description":137,"timeFrame":17},"Number of unscheduled specialist consultations","The total number of unscheduled specialist consultations will be estimated on the basis of the additional unscheduled visits made by each patient.",{"measure":139,"description":140,"timeFrame":17},"Number of unplanned hospitalizations","The total number of unplanned hospital admissions will be estimated on the basis of recorded incidents that led to hospitalisation.",{"measure":142,"description":143,"timeFrame":17},"Number of visits by the home care nurse","The total number of home visits carried out by the home nursing support service will be estimated on the basis of the various home visits made by the service.",{"measure":145,"description":146,"timeFrame":17},"Number of physical therapy sessions","The total number of physiotherapy sessions will be estimated on the basis of the various study visits (scheduled or unscheduled additional visits) undertaken by each patient.",{"measure":148,"description":149,"timeFrame":17},"Types of primary dressings used","The different types of primary dressings prescribed by the investigator and used by the nursing PDS for the care of the wound of interest under assessment will be described.",{"measure":151,"description":152,"timeFrame":17},"Average number of primary dressings","The overall average number of primary dressings used per week by the nursing care team for the wound of interest under assessment will be described.",{"measure":154,"description":155,"timeFrame":17},"Types of secondary dressings used","The different types of secondary dressings prescribed by the investigator and used by the nursing PDS for the care of the wound of interest under assessment will be described.",{"measure":157,"description":158,"timeFrame":17},"Average number of secondary dressings","The overall average number of secondary dressings used per week by the nursing care team for the wound of interest under assessment will be described.",{"measure":160,"description":161,"timeFrame":17},"Frequency of replacement of the compression device","The frequency with which the compression dressing is changed (average number per week) will be recorded by the nursing data collection team at each study assessment visit (weekly or in the event of a wound-related complication).",null,{"allocation":164,"interventionModel":165,"interventionModelDescription":162,"primaryPurpose":166,"observationalModel":162,"timePerspective":162,"maskingInfo":167},"RANDOMIZED","PARALLEL","TREATMENT",{"masking":168,"maskingDescription":162,"whoMasked":162},"NONE",[170,176],{"label":171,"type":172,"description":173,"interventionNames":174},"Compreflex® arm","EXPERIMENTAL","Patients receiving the Compreflex® adjustable compression medical device",[175],"Device: Compreflex® adjustable compression medical device",{"label":177,"type":178,"description":179,"interventionNames":180},"Control arm","ACTIVE_COMPARATOR","Patients treated with one of the multi-type compression bandage kits reimbursed in France. The choice and brand of compression device will be at the discretion of the investigator based on their treatment practices.",[181,182,183,184,185],"Device: Multi-type compression bandage kit UrgoK2®","Device: Multi-type compression bandage kit Coban 2","Device: Multi-type compression bandage kit PROFORE","Device: Multi-type compression bandage kit ROSIDAL SYS","Device: Multi-type compression bandage kit Biflex Short Strech®",[187,192,196,200,204,208],{"type":188,"name":189,"description":190,"armGroupLabels":191,"otherNames":162},"DEVICE","Multi-type compression bandage kit UrgoK2®","Patients randomly allocated to treatment by UrgoK2®, one of the multi-type compression bandage kits reimbursed in France. The choice and brand of compression device will be at the discretion of the investigator based on their treatment practices.",[177],{"type":188,"name":193,"description":194,"armGroupLabels":195,"otherNames":162},"Compreflex® adjustable compression medical device","Patients randomly allocated to treatment by the Compreflex® adjustable compression medical device",[171],{"type":188,"name":197,"description":198,"armGroupLabels":199,"otherNames":162},"Multi-type compression bandage kit Coban 2","Patients randomly allocated to treatment by Coban 2, one of the multi-type compression bandage kits reimbursed in France. The choice and brand of compression device will be at the discretion of the investigator based on their treatment practices.",[177],{"type":188,"name":201,"description":202,"armGroupLabels":203,"otherNames":162},"Multi-type compression bandage kit PROFORE","Patients randomly allocated to treatment by PROFORE, one of the multi-type compression bandage kits reimbursed in France. The choice and brand of compression device will be at the discretion of the investigator based on their treatment practices.",[177],{"type":188,"name":205,"description":206,"armGroupLabels":207,"otherNames":162},"Multi-type compression bandage kit ROSIDAL SYS","Patients randomly allocated to treatment by ROSIDAL SYS, one of the multi-type compression bandage kits reimbursed in France. The choice and brand of compression device will be at the discretion of the investigator based on their treatment practices.",[177],{"type":188,"name":209,"description":210,"armGroupLabels":211,"otherNames":162},"Multi-type compression bandage kit Biflex Short Strech®","Patients randomly allocated to treatment by Biflex Short Strech®, one of the multi-type compression bandage kits reimbursed in France. The choice and brand of compression device will be at the discretion of the investigator based on their treatment practices.",[177],[213],{"name":214,"affiliation":215,"role":216},"Dr. Léger","Clinique Pasteur Toulouse","PRINCIPAL_INVESTIGATOR",[218],{"name":219,"role":220,"phone":221,"phoneExt":162,"email":222},"Anne Graissaguel","CONTACT","+33 4 77 36 08 90","anne.graissaguel@sigvaris.com",[224,241,254,268,281,291,304,317,330,343,353,366,379,389],{"facility":225,"status":226,"city":227,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":230,"geoPoint":235,"contacts":236},"Cabinet CARDIOPTIM","NOT_YET_RECRUITING","Besançon","France","FR",{"type":231,"coordinates":232},"Point",[233,234],6.01815,47.24878,{"lat":234,"lon":233},[237],{"name":238,"role":220,"phone":239,"phoneExt":162,"email":240},"Samuel BELIARD","+33 3 81 47 21 18","sbeliard@cardioptim.fr",{"facility":242,"status":226,"city":243,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":244,"geoPoint":248,"contacts":249},"Cabinet médical","Bordeaux",{"type":231,"coordinates":245},[246,247],-0.58046,44.84124,{"lat":247,"lon":246},[250],{"name":251,"role":220,"phone":252,"phoneExt":162,"email":253},"Antoine DIARD","+33 5 56 40 28 61","antoine.diard@sfmv.fr",{"facility":255,"status":256,"city":257,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":258,"geoPoint":262,"contacts":263},"Groupe Hospitalier Mutualiste de Grenoble","RECRUITING","Grenoble",{"type":231,"coordinates":259},[260,261],5.71479,45.17869,{"lat":261,"lon":260},[264],{"name":265,"role":220,"phone":266,"phoneExt":162,"email":267},"Benjamin SONNET","+33 4 76 70 75 05","benjamin.sonnet@avec.fr",{"facility":269,"status":226,"city":270,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":271,"geoPoint":275,"contacts":276},"CHU Grenoble Alpes-hôpital Michallon","La Tronche",{"type":231,"coordinates":272},[273,274],5.74629,45.20507,{"lat":274,"lon":273},[277],{"name":278,"role":220,"phone":279,"phoneExt":162,"email":280},"Sophie BLAISE","+33 4 76 76 55 47","sblaise@chu-grenoble.fr",{"facility":282,"status":226,"city":283,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":284,"geoPoint":288,"contacts":289},"Centre de Médecine Vasculaire Interventionnelle","Langon",{"type":231,"coordinates":285},[286,287],-0.24986,44.55277,{"lat":287,"lon":286},[290],{"name":251,"role":220,"phone":252,"phoneExt":162,"email":253},{"facility":292,"status":226,"city":293,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":294,"geoPoint":298,"contacts":299},"Hôpital Saint Eloi","Montpellier",{"type":231,"coordinates":295},[296,297],3.87635,43.61093,{"lat":297,"lon":296},[300],{"name":301,"role":220,"phone":302,"phoneExt":162,"email":303},"Monira NOU","+33 4 67 33 70 28","m-nou@chu-montpellier.fr",{"facility":305,"status":226,"city":306,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":307,"geoPoint":311,"contacts":312},"CHU Pasteur 1","Nice",{"type":231,"coordinates":308},[309,310],7.26608,43.70313,{"lat":310,"lon":309},[313],{"name":314,"role":220,"phone":315,"phoneExt":162,"email":316},"Pascal GIORDANA","+33 4 92 03 38 35","giordana.p@chu-nice.fr",{"facility":318,"status":226,"city":319,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":320,"geoPoint":324,"contacts":325},"CH de Paimpol","Paimpol",{"type":231,"coordinates":321},[322,323],-3.0466,48.77831,{"lat":323,"lon":322},[326],{"name":327,"role":220,"phone":328,"phoneExt":162,"email":329},"Cécile MOISAN","+332 96 55 61 80","cecile.moisan@ch-stbrieuc.fr",{"facility":331,"status":226,"city":332,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":333,"geoPoint":337,"contacts":338},"Hôpital Rothschild","Paris",{"type":231,"coordinates":334},[335,336],2.3488,48.85341,{"lat":336,"lon":335},[339],{"name":340,"role":220,"phone":341,"phoneExt":162,"email":342},"Hester COLBOC","+33 1 40 19 34 15","hester.colboc@aphp.fr",{"facility":344,"status":226,"city":332,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":345,"geoPoint":347,"contacts":348},"Hôpital Saint Joseph",{"type":231,"coordinates":346},[335,336],{"lat":336,"lon":335},[349],{"name":350,"role":220,"phone":351,"phoneExt":162,"email":352},"Ulrique MICHON-PASTUREL","+33 1 44 12 33 33","umichon-pasturel@ghpsj.fr",{"facility":354,"status":226,"city":355,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":356,"geoPoint":360,"contacts":361},"CHU Saint Etienne","Saint-Priest-en-Jarez",{"type":231,"coordinates":357},[358,359],4.37678,45.4739,{"lat":359,"lon":358},[362],{"name":363,"role":220,"phone":364,"phoneExt":162,"email":365},"Jean-Luc PERROT","+33 4 77 82 85 08","j.luc.perrot@chu-st-etienne.fr",{"facility":367,"status":256,"city":368,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":369,"geoPoint":373,"contacts":374},"Centre de cicatrisation Clinique Pasteur","Toulouse",{"type":231,"coordinates":370},[371,372],1.44367,43.60426,{"lat":372,"lon":371},[375],{"name":376,"role":220,"phone":377,"phoneExt":162,"email":378},"Philippe LEGER","+33 5 62 21 16 99","pleger@clinique-pasteur.com",{"facility":380,"status":226,"city":368,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":381,"geoPoint":383,"contacts":384},"CHU Rangueil Toulouse",{"type":231,"coordinates":382},[371,372],{"lat":372,"lon":371},[385],{"name":386,"role":220,"phone":387,"phoneExt":162,"email":388},"Julie MALLOIZEL-DELAUNAY","+33 5 61 32 26 54","malloizel-delaunay.j@chu-toulouse.fr",{"facility":390,"status":226,"city":391,"state":162,"zip":162,"country":228,"countryCode":229,"cosmosGeoPoint":392,"geoPoint":396,"contacts":397},"Centre Léon Blum","Villeurbanne",{"type":231,"coordinates":393},[394,395],4.8795,45.76601,{"lat":395,"lon":394},[398],{"name":399,"role":220,"phone":400,"phoneExt":162,"email":401},"Christine JURUS","+33 4 72 82 67 61","dr.jurus@gmail.com",{"type":403,"investigatorFullName":162,"investigatorTitle":162,"investigatorAffiliation":162,"oldNameTitle":162,"oldOrganization":162},"SPONSOR",[405],{"name":406,"class":407},"HEVA - Lyon","UNKNOWN","100666325","study-on-the-compreflex-compression-device-in-the-local-treatment-of-venous-leg-ulcers-100666325",false,"NCT07952984","Study on the Compreflex® Compression Device in the Local Treatment of Venous Leg Ulcers","Clinical Investigation of the Compreflex® Compression Device in the Local Treatment of Venous Leg Ulcers: Randomized Non-inferiority Clinical Trial","GLOBUL","Inclusion Criteria:\n\n* Adult patient (\\> 18 years old)\n* Patient with stage C6 or C6R venous leg ulcer (CEAP classification)\n* Patients with an Ankle Brachial Index (ABI) \\> 0.8 and \\\u003C 1.4 or a toe systolic blood pressure (TSBP) \\> 0.7\n* Patients with a wound that is 1 to 24 months old\n* Patients with a wound surface area between 2 and 50 cm²\n* Patients available for 12 weeks of follow-up\n* Patients able to participate in the study\n* Patients who have signed the consent form for participation in the study\n* Patients affiliated with a social security system\n\nExclusion Criteria:\n\n* Patient with a necrotic ulcer\n* Patient scheduled for interventional treatment of varicose veins or post-thrombotic syndrome in the affected lower limb within the next 3 months\n* Patient with ankle systolic pressure (ASP) \\\u003C 60 mmHg or toe systolic pressure (TSP) \\\u003C 30 mmHg\n* Patients with ankle systolic pressure (ASP) \\\u003C 60 mmHg or toe systolic pressure (TSP) \\\u003C 30 mmHg\n* Patients with cancer-related wounds\n* Patients with wounds located on the forefoot or thigh\n* Patients with peripheral neuropathy\n* Patients with a history of superficial or deep vein thrombosis within 3 months prior to inclusion in the study\n* Patients with severe heart failure (NYHA class III or IV)\n* Patients with scleroderma\n* Patients with active cancer (excluding basal cell carcinomas)\n* Patients undergoing chemotherapy, long-term immunosuppressive therapy, or long-term corticosteroid therapy\n* Patients deprived of their liberty\n* Patients unable to sign the consent form for participation in the study","ALL","18 Years",{"count":419,"type":420},374,"ESTIMATED","INTERVENTIONAL",[423],"NA","The goal of this clinical investigation is to compare the Compreflex® adjustable compression medical device with all multi-type compression bandage kits reimbursed in France in patients with venous leg ulcer (VLU). The main question it aims to answer is: Is the adjustable Compreflex® compression device from Sigvaris non inferior to the multi-type bandage kits marketed and reimbursed in France for the treatment of VLU.\n\nResearchers will compare the adjustable Compreflex® compression device to the multi-type bandage kits marketed in France on the complete healing of VLU.\n\nParticipants will be randomly allocated to the adjustable Compreflex® compression device or to a multi-type bandage kit, according to the study physican current practice. Then they will be followed-up according to routine patient care, on-site by the study physician and at home by a nurse. Only additional procedures will be added to certain visits:\n\n* Photography of the wound taken by the healthcare providers\n* Questionnaires regarding patients quality of life, satisfaction",[426],"Venous Leg Ulcer (VLU)","2026-11-16",{"date":429,"type":430},"2026-11-23","ACTUAL",{"date":432,"type":430},"2026-01-07",{"date":434,"type":420},"2028-04",{"name":5,"class":6},14]