[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100660778":3},{"organization":4,"outcomesModule":7,"designInfo":30,"detailedDescription":29,"studyPopulation":29,"armGroups":35,"interventions":41,"overallOfficials":29,"centralContacts":29,"locations":47,"responsibleParty":74,"collaborators":29,"id":76,"slug":77,"hasResults":78,"nctId":79,"briefTitle":80,"officialTitle":80,"acronym":81,"eligibilityCriteria":82,"healthyVolunteers":83,"sex":84,"minAge":85,"maxAge":86,"enrollmentInfo":87,"targetDuration":29,"studyType":90,"phases":91,"briefSummary":92,"conditions":93,"keywords":96,"overallStatus":50,"whyStopped":29,"lastUpdateSubmitDate":104,"lastUpdatePostDateStruct":105,"startDateStruct":108,"completionDateStruct":110,"leadSponsor":112,"locationsCount":113},{"fullName":5,"class":6},"Cliniques universitaires Saint-Luc- Université Catholique de Louvain","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":29},[9],{"measure":10,"description":11,"timeFrame":12},"Evaluation of SpO₂ Resaturation Following Voluntary Apnea","To characterize the temporal behavior of a modern finger pulse oximeter during voluntary apnea in healthy volunteers, with a particular focus on the delay (in seconds) between physiological reoxygenation and displayed SpO₂ (Time interval in seconds between the first breath following apnea and the first increase in SpO2.)","From enrollment to the end of the inclusion, estimated at approximately 10 months from the start of enrollment",[14,17,20,23,26],{"measure":15,"description":16,"timeFrame":12},"Comparison of SpO₂ Temporal Parameters Between Finger and Ear Sensors","Saturation sensors will be placed on the ears and fingers of healthy volunteers.\n\nSaturation parameters will be recorded from both sensors and compared with the SpO2 saturation level (baseline SpO2):\n\n* Time (in seconds) between the onset of apnea and a decrease of ≥ 2% from baseline SpO2\n* Time (in seconds) between the onset of apnea and the lowest SpO2 observed before the start of resaturation\n* Variable describing whether the SpO2 nadir (the lowest value) occurs before or after the resumption of ventilation",{"measure":18,"description":19,"timeFrame":12},"Quantification of SpO₂ Measurement Delay Between Measurement Sites","To quantify the magnitude of the SpO₂ measurement delay (in seconds) between the two measurement sites during the reoxygenation phase.",{"measure":21,"description":22,"timeFrame":12},"Assessment of Intra-Individual Measurement Variability","To assess intra-individual variability in key measurements (focus on the delay in seconds between physiological reoxygenation and displayed SpO2) across repeated apnea tests (2 different apnea)",{"measure":24,"description":25,"timeFrame":12},"Evolution of the Perfusion Index (PI) during Apnea and Reoxygenation by finger\u002Fauricular pulse oximeter","To describe changes in the perfusion index (PI in %) during apnea and reoxygenation. Baseline PI (%) will be recorded at finger and auricular sites in healthy volunteers over time in seconds. Minimum PI during apnea, magnitude of PI change during apnea, PI recovery time (in seconds) after rebreathing.",{"measure":27,"description":28,"timeFrame":12},"Physiological Factors Associated with SpO₂ Response Delay","To explore physiological factors associated with delayed SpO₂ response (in seconds), including individual characteristics and baseline hemodynamic parameters (BMI in kg\u002Fm\\^2, medical history, chronic treatments).",null,{"allocation":31,"interventionModel":32,"interventionModelDescription":29,"primaryPurpose":6,"observationalModel":29,"timePerspective":29,"maskingInfo":33},"NA","SINGLE_GROUP",{"masking":34,"maskingDescription":29,"whoMasked":29},"NONE",[36],{"label":37,"type":6,"description":38,"interventionNames":39},"Comparison of Finger and Ear Pulse Oximetry During Voluntary Apnea","After a 5-minute resting period, two pulse oximetry sensors will be placed simultaneously: a finger sensor and an ear sensor (earlobe). Baseline parameters will be recorded.\n\nThe apnea protocol will consist of a maximal inspiration followed by voluntary breath-holding. Throughout the procedure, oxygen saturation (SpO₂), heart rate, and perfusion index will be continuously recorded until the values return to baseline.\n\nThe monitor screens will be video-recorded to allow precise temporal analysis of events (onset of apnea, resumption of breathing, desaturation, nadir, and resaturation).\n\nAfter a further 5-minute resting period, the procedure will be repeated a second time.",[40],"Diagnostic Test: Voluntary Apnea",[42],{"type":43,"name":44,"description":45,"armGroupLabels":46,"otherNames":29},"DIAGNOSTIC_TEST","Voluntary Apnea","Two pulse oximetry sensors (finger and earlobe) will be simultaneously applied, and baseline oxygen saturation (SpO₂), heart rate, and perfusion index will be recorded. The participant will then perform two voluntary apnea tests, during which these parameters will be continuously monitored to assess the timing of apnea, desaturation, nadir, and resaturation.",[37],[48],{"facility":49,"status":50,"city":51,"state":29,"zip":52,"country":53,"countryCode":54,"cosmosGeoPoint":55,"geoPoint":60,"contacts":61},"Cliniques Universitaires Saint-Luc","RECRUITING","Brussels","1200","Belgium","BE",{"type":56,"coordinates":57},"Point",[58,59],4.34878,50.85045,{"lat":59,"lon":58},[62,68,72],{"name":63,"role":64,"phone":65,"phoneExt":66,"email":67},"Alexandre Niset, MD","CONTACT","027641638","+32","alexandre.niset@saintluc.uclouvain.be",{"name":69,"role":64,"phone":70,"phoneExt":66,"email":71},"Lara Absil, PhD","027648645","lara.absil@saintluc.uclouvain.be",{"name":63,"role":73,"phone":29,"phoneExt":29,"email":29},"PRINCIPAL_INVESTIGATOR",{"type":75,"investigatorFullName":29,"investigatorTitle":29,"investigatorAffiliation":29,"oldNameTitle":29,"oldOrganization":29},"SPONSOR","100660778","temporal-dynamics-of-peripheral-spo-during-reoxygenation-100660778",false,"NCT07884500","Temporal Dynamics of Peripheral SpO₂ During Reoxygenation","PulseOx","Inclusion Criteria:\n\n* Healthy adult volunteers aged 18 to 60 years\n* Able to perform voluntary apnea for at least 30 seconds\n* Written informed consent, read and signed by the participant\n\nExclusion Criteria:\n\n* History of chronic respiratory, cardiac, or hematological disease\n* Recent respiratory infection (\\\u003C 2 weeks)\n* Use of vasoactive medications (e.g., beta-blockers, vasodilators)\n* Known or suspected pregnancy\n* Inability to understand the study information or follow the study instructions\n* Refusal to participate or withdrawal of consent",true,"ALL","18 Years","60 Years",{"count":88,"type":89},100,"ESTIMATED","INTERVENTIONAL",[31],"Pulse oximeters estimate arterial oxyhaemoglobin saturation (SaO₂) from photoplethysmographic signals recorded at peripheral sites (usually the fingertip), thus measuring the peripheral oxygen saturation (SpO₂). They are ubiquitous in emergency medicine because they offer a non-invasive, continuous measure of oxygenation and can alert clinicians to impending hypoxaemia, both during procedures such as rapid sequence intubation or sedation, or for continuous monitoring of patients. However, the accuracy of SpO₂ is often assumed to be instantaneous. This assumption is particularly hazardous during critical events involving rapid desaturation and resaturation. In such situations clinicians use SpO₂ readings to decide when to stop an apnea period during laryngoscopy and commence reoxygenation. If there is a delay between actual arterial desaturation and the displayed SpO₂, the clinician may not recognise hypoxaemia in time or may resume ventilation too late.",[94,95],"Healthy Vollunteer","Apnea",[97,98,99,100,101,102,103],"healthy vollunteer","pulse oximetry","rapid desaturation","resaturation","apnea","ear sensors","finger probes","2026-10-13",{"date":106,"type":107},"2026-10-20","ACTUAL",{"date":109,"type":107},"2026-08-03",{"date":111,"type":89},"2027-02-01",{"name":5,"class":6},1]