[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100659883":3},{"organization":4,"outcomesModule":7,"designInfo":48,"detailedDescription":59,"studyPopulation":53,"armGroups":60,"interventions":73,"overallOfficials":83,"centralContacts":88,"locations":95,"responsibleParty":113,"collaborators":117,"id":121,"slug":122,"hasResults":123,"nctId":124,"briefTitle":125,"officialTitle":126,"acronym":127,"eligibilityCriteria":128,"healthyVolunteers":123,"sex":129,"minAge":130,"maxAge":53,"enrollmentInfo":131,"targetDuration":53,"studyType":134,"phases":135,"briefSummary":137,"conditions":138,"keywords":141,"overallStatus":146,"whyStopped":53,"lastUpdateSubmitDate":147,"lastUpdatePostDateStruct":148,"startDateStruct":151,"completionDateStruct":153,"leadSponsor":155,"locationsCount":156},{"fullName":5,"class":6},"Amsterdam UMC, location VUmc","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":40},[9],{"measure":10,"description":11,"timeFrame":12},"Proportion of guideline-adherent ventilation pauses per resuscitation attempt","A ventilation pause is a compression pause during CPR in which rescue breaths are delivered. Guideline adherence per pause is defined as delivery of two ventilations, each with a device-measured expiratory tidal volume of 400-500 mL, per European Resuscitation Council recommendations. For each patient, the proportion of guideline-adherent pauses is calculated as the number of adherent pauses divided by the total analyzable pauses during the resuscitation attempt. The primary outcome is the mean of this patient-level proportion, averaged across all patients, compared between feedback and control groups.","From enrollment to the end of treatment at day 1",[14,17,21,25,28,31,34,37],{"measure":15,"description":16,"timeFrame":12},"Number of Participants with Prehospital Return of Spontaneous Circulation (ROSC)","Any return of spontaneous circulation (ROSC), defined per the Utstein Out-of-Hospital Cardiac Arrest Registry Template, at any point during the prehospital resuscitation attempt.",{"measure":18,"description":19,"timeFrame":20},"Number of Participants Surviving to 30 Days","Survival to 30 days","From enrollment to day 30",{"measure":22,"description":23,"timeFrame":24},"Number of Participants with Favorable Neurological Outcome","Favorable neurological outcome, defined as a Modified Rankin Scale (mRS) score of 0-3, where 0 indicates no symptoms and 6 indicates death, assessed at hospital discharge or 30 days.","From enrollment to hospital discharge or 30 days",{"measure":26,"description":27,"timeFrame":12},"Proportion of Guideline-Adherent Ventilations","Proportion (%) of ventilations with expiratory tidal volume 400-500 mL, per European Resuscitation Council recommendations, calculated across all ventilations pooled across patients during prehospital resuscitation. Device-recorded data, compared between feedback and control groups.",{"measure":29,"description":30,"timeFrame":12},"Expiratory Tidal Volume per Ventilation","Central tendency (mean or median) of expiratory tidal volume per ventilation, in milliliters (mL), calculated across all ventilations pooled across patients (not averaged per patient first). Device-recorded, compared between feedback and control groups.",{"measure":32,"description":33,"timeFrame":12},"Ventilation Leakage","Central tendency of gas leakage per ventilation, expressed as a percentage (%) of inspiratory tidal volume, calculated across all ventilations pooled across patients. Device-recorded, compared between feedback and control groups.",{"measure":35,"description":36,"timeFrame":12},"Ventilation Pause Duration","Duration of compression pauses in which ventilations are delivered, in seconds, calculated across all pauses pooled across patients. Device-recorded, compared between feedback and control groups.",{"measure":38,"description":39,"timeFrame":12},"Minute Ventilation","Inspiratory and expiratory minute volume, in liters per minute (L\u002Fmin), calculated across all minutes pooled across patients. Device-recorded, compared between feedback and control groups.",[41,44],{"measure":42,"description":43,"timeFrame":12},"Change in Ventilation Quality Over Time Within Resuscitation Attempts","Trend in the proportion (percentage-point change) of guideline-adherent ventilations across consecutive time intervals within a resuscitation attempt, pooled across patients. Device-recorded, compared between feedback and control groups.",{"measure":45,"description":46,"timeFrame":47},"EMS-Level Learning Curve in Ventilation Quality","Change in ventilation quality, expressed as percentage-point change in guideline adherence, at the EMS-provider level as a function of cumulative study exposure (number of cases performed). Device-recorded.","Through study completion",{"allocation":49,"interventionModel":50,"interventionModelDescription":51,"primaryPurpose":52,"observationalModel":53,"timePerspective":53,"maskingInfo":54},"RANDOMIZED","PARALLEL","Participants are randomized 1:1 to receive ventilation with real-time feedback (intervention) or with the same device operating in recording-only mode (control). Randomization is performed automatically by the study device itself: upon activation, the device randomly initiates in either feedback or recording-only mode and remains in the assigned mode for the first hour of use to ensure consistent treatment allocation.","TREATMENT",null,{"masking":55,"maskingDescription":53,"whoMasked":56},"DOUBLE",[57,58],"PARTICIPANT","OUTCOMES_ASSESSOR","Rationale: Effective ventilation is critical for maintaining oxygenation and carbon dioxide elimination during cardiopulmonary resuscitation. However, observational studies consistently show that adequate lung inflation is frequently not achieved during synchronous ventilation, in which two ventilations are delivered after every 30 chest compressions. The absence of real-time feedback during manual ventilation contributes to substantial variability in delivered tidal volumes and pressures, representing a potentially modifiable factor to improve ventilation quality and, potentially, patient outcomes.\n\nObjective: The OXY-VENT study aims to determine whether the EOlife, a real-time ventilation feedback device (VFD) can enhance ventilation quality during CPR.\n\nStudy design: The OXY-VENT study is an investigator-initiated, single-center, open-label, parallel-group, randomized controlled superiority trial designed to evaluate the efficacy of a ventilation feedback intervention versus a control device in recording-only mode on ventilation quality during cardiac arrest.\n\nStudy population: Adult patients experiencing out-of-hospital cardiac arrest treated by regional ambulance services in Utrecht, the Netherlands. Patients are managed using synchronous ventilation following immediate placement of a supraglottic airway device.\n\nIntervention: Upon activation of the VFD, participants are randomly assigned to receive ventilation in either active feedback mode (intervention) or recording-only mode (control).\n\nMain study parameters\u002Fendpoints: The primary outcome is the proportion of pauses during which guideline-adherent ventilations are administered. This is defined as the delivery of two ventilations per pause, each with an expiratory tidal volume of 400-500 mL.",[61,67],{"label":62,"type":63,"description":64,"interventionNames":65},"Feedback Group","EXPERIMENTAL","Participants receive resuscitation using the ventilation feedback device operating in feedback mode, in which real-time visual feedback is displayed to guide the provider toward a target expiratory tidal volume of 400-500 mL.",[66],"Device: Ventilation Feedback Device (Active)",{"label":68,"type":69,"description":70,"interventionNames":71},"Recording-Only (Control) Group","ACTIVE_COMPARATOR","Participants receive resuscitation using the same device operating in recording-only mode, in which ventilation parameters are recorded but no feedback is displayed to the provider.",[72],"Device: Control (Recording-Only)",[74,79],{"type":75,"name":76,"description":77,"armGroupLabels":78,"otherNames":53},"DEVICE","Ventilation Feedback Device (Active)","The same flow sensor and device measure inspiratory and expiratory tidal volume, leakage, and ventilation timing, connected between the resuscitator bag and airway device. In feedback mode, the device displays real-time visual feedback to guide the provider toward a target expiratory tidal volume of 400-500 mL.",[62],{"type":75,"name":80,"description":81,"armGroupLabels":82,"otherNames":53},"Control (Recording-Only)","A ventilation feedback device integrated into standard resuscitation equipment, used during out-of-hospital cardiac arrest. The device measures inspiratory and expiratory tidal volume, leakage, and ventilation timing via a flow sensor connected between the resuscitator bag and airway device. In this arm, the device is randomly initiated in recording-only mode, recording the same ventilation parameters without displaying any feedback to the provider.",[68],[84],{"name":85,"affiliation":86,"role":87},"Patrick Schober, MD, PhD","Amsterdam UMC","PRINCIPAL_INVESTIGATOR",[89,94],{"name":90,"role":91,"phone":92,"phoneExt":53,"email":93},"Jeroen A. van Eijk, MD","CONTACT","+31 020 566 59 69","j.vaneijk1@amsterdamumc.nl",{"name":85,"role":91,"phone":53,"phoneExt":53,"email":53},[96],{"facility":97,"status":53,"city":98,"state":53,"zip":99,"country":100,"countryCode":101,"cosmosGeoPoint":102,"geoPoint":107,"contacts":108},"RAVU","Bilthoven","3723BC","Netherlands","NL",{"type":103,"coordinates":104},"Point",[105,106],5.20139,52.13,{"lat":106,"lon":105},[109],{"name":110,"role":91,"phone":53,"phoneExt":111,"email":112},"René Boomars, Msc","+31 30 8501200","r.boomars@ravu.nl",{"type":114,"investigatorFullName":115,"investigatorTitle":116,"investigatorAffiliation":5,"oldNameTitle":53,"oldOrganization":53},"SPONSOR_INVESTIGATOR","Jeroen van Eijk","Coordinating investigator",[118],{"name":119,"class":120},"Archeon Medical","UNKNOWN","100659883","the-oxy-vent-study-100659883",false,"NCT07870551","The OXY-VENT Study","The OXY-VENT Study: an Investigator-initiated, Single-center, Parallel-group, Randomized Controlled Superiority Trial of Real-time Ventilation Feedback Versus Control to Improve Ventilation Quality in Adults With Out-of-hospital Cardiac Arrest.","OXY-VENT","Inclusion Criteria:\n\nAll adults with OHCA will be included, regardless of rhythm, whether the cardiac arrest was witnessed, or whether bystander CPR was initiated.\n\nExclusion Criteria:\n\nPediatric and traumatic cardiac arrests are excluded.","ALL","18 Years",{"count":132,"type":133},515,"ESTIMATED","INTERVENTIONAL",[136],"NA","Effective ventilation during cardiopulmonary resuscitation is essential but can be difficult to achieve consistently. Current practice relies on visible chest rise to guide ventilation volume, although this may not always accurately reflect the actual volume of air delivered. This study aims to determine whether a real-time ventilation feedback device, providing objective information on ventilation volume and air leakage, improves adherence to recommended ventilation volumes compared with standard ventilation without feedback. The study will focus on patients receiving CPR with a supraglottic airway and synchronous ventilation.",[139,140],"Cardiac Arrest (CA)","Cardiopulmonary Resuscitation (CPR)",[142,143,144,145],"ventilation","cardiopulmonary resuscitation","ventilation feedback device","advanced life support","NOT_YET_RECRUITING","2026-10-22",{"date":149,"type":150},"2026-10-27","ACTUAL",{"date":152,"type":133},"2027-01-01",{"date":154,"type":133},"2028-09-01",{"name":115,"class":6},1]