[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100666257":3},{"organization":4,"outcomesModule":7,"designInfo":30,"detailedDescription":33,"studyPopulation":34,"armGroups":35,"interventions":41,"overallOfficials":13,"centralContacts":47,"locations":13,"responsibleParty":53,"collaborators":13,"id":55,"slug":56,"hasResults":57,"nctId":58,"briefTitle":59,"officialTitle":60,"acronym":13,"eligibilityCriteria":61,"healthyVolunteers":57,"sex":62,"minAge":63,"maxAge":13,"enrollmentInfo":64,"targetDuration":67,"studyType":68,"phases":13,"briefSummary":69,"conditions":70,"keywords":77,"overallStatus":85,"whyStopped":13,"lastUpdateSubmitDate":86,"lastUpdatePostDateStruct":87,"startDateStruct":90,"completionDateStruct":92,"leadSponsor":94,"locationsCount":13},{"fullName":5,"class":6},"Arctx Medical, Inc.","INDUSTRY",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":14},[9],{"measure":10,"description":11,"timeFrame":12},"1. Time to physician-selected target temperature","Hours from initiation of ThermoCore therapy to the first core temperature in the target range that stays in range across at least two consecutive readings spanning at least 30 minutes. Only patients outside the target range at initiation are included.","From initiation of ThermoCore therapy until target temperature is achieved (up to 72 hours)",null,[15,19,23,26],{"measure":16,"description":17,"timeFrame":18},"Ability to maintain the physician-selected target temperature.","inside the physician-documented target range (or within ±0.5 °C of a single documented target value).","From target achievement until rewarming or discontinuation of ThermoCore therapy (up to 72 hours)",{"measure":20,"description":21,"timeFrame":22},"Incidence of shivering using the Bedside Shivering Assessment Scale (BSAS)","Proportion of patients with at least one BSAS score of 1 or higher during ThermoCore therapy, and the maximum BSAS score per patient (scale 0-3; higher scores mean more shivering). Reported only for sites where BSAS is routinely documented.","From initiation through discontinuation of ThermoCore therapy (up to 72 hours)",{"measure":24,"description":25,"timeFrame":22},"Distribution of temperature-control modes and clinical indications","Number and percentage of patients treated in each temperature-control mode, alone or in combination, with the number of mode changes. The four modes, assigned by protocol-defined rules from the core temperature at initiation and the physician-selected target, are induced and controlled cooling to hypothermia, induced and controlled cooling or heating to normothermia, maintenance of normothermia including fever control, and controlled warming from hypothermia. Also reported: number and percentage of patients in each physician-documented clinical indication category. Indications are reported only as counts; temperature-control performance is not analyzed by indication.",{"measure":27,"description":28,"timeFrame":29},"Healthcare provider assessment of device performance and usability","Responses to a standardized device-experience questionnaire, completed once per treatment course by the clinician most involved in placing or operating ThermoCore. It covers performance and usability during placement, setup and operation. Each item is summarized as the distribution of responses.","Through study completion, an average of 2 years",{"allocation":13,"interventionModel":13,"interventionModelDescription":13,"primaryPurpose":13,"observationalModel":31,"timePerspective":32,"maskingInfo":13},"COHORT","PROSPECTIVE","The ThermoCore Post-Market Registry (Protocol CL926) is a prospective, multi-center, observational, non-interventional registry sponsored by Arctx Medical, Inc. It will enroll up to 300 adults at approximately 30 sites in the United States and Chile over an enrollment period of approximately 24 months.\n\nDevice. ThermoCore (originally marketed as the Arctx Cool Catheter Set) is a 14 French, single-use, multi-lumen catheter placed by the nasogastric route only. It connects through the ThermoCore Extension Line to the Blanketrol III Hyper-Hypothermia System (Gentherm Medical, model 233) to provide temperature control, and also provides gastric decompression\u002Fsuctioning and enteral administration of fluids. It is cleared by the U.S. FDA under 510(k) K250632 (21 CFR 870.5910, Class II) for use up to 72 hours. All registry patients are treated with ThermoCore connected to the Blanketrol III, used according to the labeling authorized in the country of use.\n\nDesign. The protocol does not assign or alter treatment. The treating physician independently determines that temperature control is indicated and selects ThermoCore before a patient is included. The protocol does not specify a target temperature, duration of therapy, temperature-control algorithm, or rewarming rate. The registry includes all four temperature-control modes, alone or in combination: induced and controlled cooling to hypothermia, induced and controlled cooling or heating to normothermia, maintenance of normothermia including fever control, and controlled warming from hypothermia. Each patient's mode is assigned from the core temperature at initiation and the physician-selected target, using rules defined in the protocol. Clinical indication is recorded as documented by the treating physician and is used to describe the population, not to determine eligibility.\n\nData collection. Data are abstracted from routine clinical records from initiation of ThermoCore therapy through discontinuation. Core temperature is taken from the site's routine non-esophageal monitoring (for example, bladder, rectal, or intravascular), recorded at least hourly; esophageal measurement is not used because it cannot be performed accurately with ThermoCore in place. Data include the physician-selected target temperature and any changes, the temperature-control mode and clinical indication, shivering (Bedside Shivering Assessment Scale, where routinely documented), therapy pauses, the start of rewarming, the time of and reason for discontinuation, and device-related adverse events and deficiencies. After ThermoCore is discontinued, with no fixed deadline, the clinician most involved in placing or operating the device completes a standardized device-experience questionnaire. There is no registry-specific follow-up beyond the treatment course.\n\nSafety reporting. Adverse events are not solicited. Adverse events that the investigator identifies during routine care and considers related to ThermoCore, together with device deficiencies and complaints, are recorded and reported through the sponsor's complaint-handling process and to the IRB\u002FEC as required.\n\nAnalysis. The registry is descriptive and exploratory and is not powered to test a hypothesis. Results will be summarized with descriptive statistics overall and by temperature-control mode and by country. Clinical indications are reported only as counts; temperature-control performance is not analyzed by indication. Time-based temperature endpoints are calculated time-weighted (trapezoidal rule) so that sites recording continuously and hourly are comparable.\n\nConsent. At all sites, in the United States and Chile, registry participation requires a short written data consent, signed before any registry data are recorded by the patient or, if the patient lacks decision-making capacity, by the patient's legally authorized representative. Enrollment does not wait for the patient to regain capacity; patients who lack capacity and have no available representative are not enrolled, and a patient who regains capacity is given the consent to read and may withdraw. Use of ThermoCore itself is a clinical decision and does not require research consent. U.S. consent forms include HIPAA authorization. Consent is reviewed by the IRB of record (Univo IRB). At the Chilean site, a legal representative may sign where the Chilean ethics committee permits.","Adult patients requiring active temperature control (induced and controlled cooling to hypothermia, induced and controlled cooling or heating to normothermia, maintenance of normothermia including fever control, or controlled warming from hypothermia) for whom the treating physician has independently selected ThermoCore as part of routine clinical care, at participating sites in the United States and Chile.",[36],{"label":37,"type":13,"description":38,"interventionNames":39},"ThermoCore-treated patients","Adults whose treating physician has independently determined that active temperature control is indicated and has selected ThermoCore as part of routine care.",[40],"Device: Device: ThermoCore",[42],{"type":43,"name":44,"description":45,"armGroupLabels":46,"otherNames":13},"DEVICE","Device: ThermoCore","14 French, single-use, multi-lumen nasogastric catheter connected to the Blanketrol III Hyper-Hypothermia System. Used per its labeling for active temperature control (cooling, warming, or maintenance of normothermia, including fever control) for up to 72 hours. Use is determined by the treating physician, not by the registry.",[37],[48],{"name":49,"role":50,"phone":51,"phoneExt":13,"email":52},"Cindy Grabowski","CONTACT","(612) 245-3733","cgrabowski@arctxmedical.com",{"type":54,"investigatorFullName":13,"investigatorTitle":13,"investigatorAffiliation":13,"oldNameTitle":13,"oldOrganization":13},"SPONSOR","100666257","thermocore-post-market-registry-100666257",false,"NCT07951840","ThermoCore Post-Market Registry","Clinical Experience With ThermoCoreTM in Adult Patients Requiring Temperature Control","Inclusion Criteria:\n\n* Adult patient requiring active temperature control;\n* Treating physician has independently determined active temperature control is indicated and selected ThermoCore;\n* Core temperature recorded at least hourly by a non-esophageal method as part of routine care; device use consistent with the labeling authorized in the country of use\n\nExclusion Criteria:\n\n* Adequate non-esophageal core temperature monitoring cannot be performed;\n* Participation in data collection would interfere with clinical care;\n* Concurrent study participation that would confound interpretation","ALL","18 Years",{"count":65,"type":66},300,"ESTIMATED","6 Days","OBSERVATIONAL","The goal of this observational registry is to determine how well ThermoCore controls body temperature in adults whose doctors have determined they need temperature management. ThermoCore is an FDA-cleared tube that is placed through the nose into the stomach. It connects to a temperature-control machine to cool or warm the patient from inside the body, and it can also drain the stomach or deliver fluids, like a standard nasogastric tube.\n\nThe main questions this registry aims to answer are: - How quickly does ThermoCore bring a patient's temperature to the target the doctor chose? - How well does ThermoCore keep the temperature at that target? - How often do patients shiver during treatment? - Which temperature-control approaches and medical conditions do doctors use ThermoCore for? - How easy do doctors and nurses find ThermoCore to place and use?\n\nThe treating doctor decides, on their own, whether a patient needs temperature control and whether to use ThermoCore. Being in the registry does not change the patient's care, and there are no extra tests, procedures, or visits. Researchers will collect information that is already recorded in the medical record while ThermoCore is in use (up to 72 hours), such as temperature readings, shivering scores, and any device problems. The clinician who placed or operated the device will also complete a short questionnaire about their experience after ThermoCore is removed.",[71,72,73,74,75,76],"Active Temperature Management","Total Temperature Management","Normothermia","Hyperthermia","Hypothermia","Active Temperature Control",[76,78,73,75,74,79,80,81,82,83,84],"Temperature Management","Fever Control","Controlled Cooling","Controlled Warming","Nasogastric","Gastric heat exchange","post-market registry","NOT_YET_RECRUITING","2026-11-17",{"date":88,"type":89},"2026-11-23","ACTUAL",{"date":91,"type":66},"2027-01-01",{"date":93,"type":66},"2029-02-28",{"name":5,"class":6}]