[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100665265":3},{"organization":4,"outcomesModule":7,"designInfo":14,"detailedDescription":13,"studyPopulation":13,"armGroups":20,"interventions":27,"overallOfficials":13,"centralContacts":33,"locations":43,"responsibleParty":62,"collaborators":13,"id":64,"slug":65,"hasResults":66,"nctId":67,"briefTitle":68,"officialTitle":69,"acronym":13,"eligibilityCriteria":70,"healthyVolunteers":66,"sex":71,"minAge":72,"maxAge":13,"enrollmentInfo":73,"targetDuration":13,"studyType":76,"phases":77,"briefSummary":78,"conditions":79,"keywords":81,"overallStatus":83,"whyStopped":13,"lastUpdateSubmitDate":84,"lastUpdatePostDateStruct":85,"startDateStruct":88,"completionDateStruct":90,"leadSponsor":92,"locationsCount":93},{"fullName":5,"class":6},"CooperVision International Limited (CVIL)","INDUSTRY",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":13},[9],{"measure":10,"description":11,"timeFrame":12},"Subjective Comfort","Subjective comfort on insertion (0-100 Visual analogue scale)","Baseline, 1 week, and 1 month.",null,{"allocation":15,"interventionModel":16,"interventionModelDescription":13,"primaryPurpose":17,"observationalModel":13,"timePerspective":13,"maskingInfo":18},"NA","SINGLE_GROUP","TREATMENT",{"masking":19,"maskingDescription":13,"whoMasked":13},"NONE",[21],{"label":22,"type":23,"description":24,"interventionNames":25},"Refit to Fanfilcon A Sphere Contact Lens","EXPERIMENTAL","Habitual wears of Confilcon A soft sphere contact lenses Refitted to Fanfilcon A sphere contact lense s and followed for one month.",[26],"Device: Fanfilcon A sphere Contact lens",[28],{"type":29,"name":30,"description":31,"armGroupLabels":32,"otherNames":13},"DEVICE","Fanfilcon A sphere Contact lens","Participants are refit from their habitual sphere soft contact lenses to fanfilcon A sphere contact lenses and wear the lenses for approximately one month according to the study protocol.",[22],[34,39],{"name":35,"role":36,"phone":37,"phoneExt":13,"email":38},"Jose Vega, O.D., MSc., PhD, FAAO","CONTACT","9256402964","JVega2@coopervision.com",{"name":40,"role":36,"phone":41,"phoneExt":13,"email":42},"Komalpreet Kaur, BS","9256604439","KoKaur@coopervision.com",[44],{"facility":45,"status":13,"city":46,"state":47,"zip":48,"country":49,"countryCode":50,"cosmosGeoPoint":51,"geoPoint":56,"contacts":57},"Consultorio Optométrico","México","State of Mexico","CP 06760","Mexico","MX",{"type":52,"coordinates":53},"Point",[54,55],-99.12355,19.69237,{"lat":55,"lon":54},[58],{"name":59,"role":36,"phone":60,"phoneExt":13,"email":61},"Dr. Ruben Velazquez Guerrero, OD","+525528991976","rubenvg@unam.mx",{"type":63,"investigatorFullName":13,"investigatorTitle":13,"investigatorAffiliation":13,"oldNameTitle":13,"oldOrganization":13},"SPONSOR","100665265","title-clinical-performance-and-outcomes-after-sphere-lens-transition-100665265",false,"NCT07940426","Title: Clinical Performance and Outcomes After Sphere Lens Transition","Clinical Performance and Patient Outcomes When Transitioning From Comfilcon A Sphere to Fanfilcon A Sphere Lenses.","Inclusion Criteria:\n\n1. Participants with eyes appropriate for the study being conducted\n2. They are at least 18 years of age.\n3. They understand their rights as a research participant and are willing and able to sign a Statement of Informed Consent.\n4. Current habitual wearer of Biofinity soft sphere contact lenses with contact lens power ranging from +8.00 to -12.00 DS.\n5. Anisometropia no greater than 1.50D, based on contact lens power spherical equivalent.\n6. Can achieve visual acuity of at least 0.1 logMAR (20\u002F25) in each eye with contact lenses.\n7. Able to wear the study contact lenses for 6 days a week, minimum 8 hours a day.\n8. Can be fitted with the study contact lenses (Avaira Vitality® sphere).\n9. They agree not to participate in any other clinical research study while enrolled in this study.\n\nExclusion Criteria:\n\n\\- 1. Anterior segment infection, inflammation or abnormality 2. Any active anterior segment ocular disease that would contraindicate contact lens wear 3. The use of systemic or ocular medications that would contraindicate contact lens wear 4. History of herpetic keratitis 5. History of refractive surgery or irregular cornea 6. Slit lamp findings that are more serious than grade 1 (ISO scale). 7. Inactive (i.e. ghost) vessels greater than 1 mm of penetration into the cornea 8. They have corneal distortion resulting from previous hard or rigid lens wear or have keratoconus.\n\n9\\. They have participated in a contact lens or contact lens care product clinical trial in the past 30 days","ALL","18 Years",{"count":74,"type":75},36,"ESTIMATED","INTERVENTIONAL",[15],"To evaluate subjective and clinical outcomes after transitioning from one sphere soft contact lens to another over a one-month period.",[80],"Astigmatism",[82],"myopia","NOT_YET_RECRUITING","2026-11-11",{"date":86,"type":87},"2026-11-16","ACTUAL",{"date":89,"type":75},"2026-11",{"date":91,"type":75},"2027-02",{"name":5,"class":6},1]