[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100660922":3},{"organization":4,"outcomesModule":7,"designInfo":22,"detailedDescription":29,"studyPopulation":21,"armGroups":30,"interventions":36,"overallOfficials":42,"centralContacts":46,"locations":21,"responsibleParty":56,"collaborators":21,"id":60,"slug":61,"hasResults":62,"nctId":63,"briefTitle":64,"officialTitle":65,"acronym":21,"eligibilityCriteria":66,"healthyVolunteers":62,"sex":67,"minAge":68,"maxAge":69,"enrollmentInfo":70,"targetDuration":21,"studyType":73,"phases":74,"briefSummary":75,"conditions":76,"keywords":21,"overallStatus":78,"whyStopped":21,"lastUpdateSubmitDate":79,"lastUpdatePostDateStruct":80,"startDateStruct":83,"completionDateStruct":85,"leadSponsor":87,"locationsCount":21},{"fullName":5,"class":6},"Assiut University","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":21},[9],{"measure":10,"description":11,"timeFrame":12},"The percentage of success of LBBAP procedure with the guidance of intraprocedural 3D-TEE.","The investigators will reach the accurate site of the lead implantation in interventricular septum to pace the left bundle branch by the accurate imaging tool (intraprocedural 3D-TEE).","half to one hour for each case implantation.",[14,18],{"measure":15,"description":16,"timeFrame":17},"The rate 'percent' of the lead related complications during follow up of the cases after implantation.","The participants follow up will be after one week and then after three months to detect the complications by the measurement tool (change in baseline programming pacing threshold in volt).","one week to three months",{"measure":19,"description":20,"timeFrame":17},"Assessment of the lead site inside the interventricular septum for the rate 'percent' of lead displacement complications during follow up.","The measurement tool is transthoracic echocardiography for measurement the lead site in mm inside the interventricular septum and any change in shape of electrocardiogram waves.",null,{"allocation":23,"interventionModel":24,"interventionModelDescription":25,"primaryPurpose":6,"observationalModel":21,"timePerspective":21,"maskingInfo":26},"NA","SINGLE_GROUP","* The investigators will select the pediatric cases who have an indications for permanent pacemaker implantation followed contemporary guideline-based recommendations.\n* All patients will undergo implantation of permanent pacemaker either single or dual chamber under fluoroscopic guidance according the EHRA procedural recommendations with the guidance of (3D-TEE ) for more accurate lead positioning through direct visualization of the interventricular septum.",{"masking":27,"maskingDescription":28,"whoMasked":21},"NONE","The aim of the study to explore the role of intraprocedural 3D-TEE in LBBAP lead implantation, procedural efficiency, safe lead positioning and electrical outcomes in pediatrics.","* Cardiac pacing in children usually is needed in the setting of congenital atrioventricular block or atrioventricular block after heart surgery.\n* Considering that the pediatric patients usually require high percentages of ventricular stimulation up to 100%.\n* This high percentage is a risk factor for pacing-associated cardiomyopathy in the pediatric population.\n* Left bundle branch area pacing (LBBAP) is one of the emerging conductive system pacing varieties for better physiological cardiac pacing.\n* LBBAP provides excellent pacing parameters with much lower incidence of pacing induced cardiomyopathy.\n* The implantation of pacemakers in children is still challenging due to their smaller body size, continuing growth, with higher rate of lead related complications compared to older patients.\n* Fluoroscopic guided optimal lead position is a challenge in some cases especially children due to previous mentioned reasons.\n* There is no specific data regarding the three-dimensional transesophageal echocardiography (3D-TEE) role in the LBBAP implantation procedure in adults or pediatric patients, so the investigators will investigate whether intraprocedural 3D-TEE can facilitate LBBAP lead implantation, improve procedural efficiency, ensure safe lead positioning, and identify any lead complications during follow-up.",[31],{"label":32,"type":6,"description":33,"interventionNames":34},"Pediatric patients who are indicated for LBBAP","1. Pediatric patients aged \\\u003C18years old.\n2. Case who have Congenital complete atrioventricular block, atrioventricular block as a complication after heart surgery, and symptomatic bradycardia .\n3. Indications for permanent pacemaker implantation followed contemporary guideline-based recommendations.\n4. Pediatric patients had previous right ventricular lead implantation and deterioration of LV systolic function.",[35],"Procedure: Left Bundle Branch Pacing",[37],{"type":38,"name":39,"description":40,"armGroupLabels":41,"otherNames":21},"PROCEDURE","Left Bundle Branch Pacing","Implantation of permanent pacemaker either single or dual chamber under fluoroscopic guidance according the EHRA procedural recommendations with add value or 3D-TEE in the implantation procedure.",[32],[43],{"name":44,"affiliation":5,"role":45},"Mahmoud Abdelsabour, Professor","STUDY_DIRECTOR",[47,52],{"name":48,"role":49,"phone":50,"phoneExt":21,"email":51},"Alaa Rashad, Assistant Lecturer","CONTACT","01026453282","alaarashad084@gmail.com",{"name":53,"role":49,"phone":54,"phoneExt":21,"email":55},"Mahmoud Abdelsabour, Professsor","01001202779","m_abd_elsabour@aun.edu.eg",{"type":57,"investigatorFullName":58,"investigatorTitle":59,"investigatorAffiliation":5,"oldNameTitle":21,"oldOrganization":21},"PRINCIPAL_INVESTIGATOR","Alaa Rashad Ali","Assistant Lecturer of Cardiovascular Medicine","100660922","transesophageal-echocardiography-in-conductive-system-pacing-in-pediatric-patients-100660922",false,"NCT07882563","Transesophageal Echocardiography in Conductive System Pacing in Pediatric Patients","The Incremental Value of Transesophageal Echocardiography in Conductive System Pacing in Pediatric Patients","The study will include patients fulfilling our inclusion criteria.\n\nInclusion Criteria:\n\n1. Pediatric patients aged \\\u003C18years old.\n2. Congenital complete atrioventricular block, atrioventricular block as a complication after heart surgery, and symptomatic bradycardia associated with channelopathies.\n3. Indications for permanent pacemaker implantation followed contemporary guideline-based recommendations.\n4. Pediatric patients had previous right ventricular lead implantation and deterioration of LV systolic function.\n\nExclusion Criteria:\n\n1. Patients will not attend for follow up after implantation.\n2. Patients have critical systematic illness which may interfere with cardiac function assessment.\n3. Patients have poor echocardiographic window.\n\nAll patients will be subjected to:\n\nA. Full history taking: including age, sex, history of DM, HTN, history of CHD or any previous cardiac intervention, symptoms of heart failure, dizziness or syncope and history of any previous arrhythmia.\n\nB. Full Physical examination:\n\n* General examination Systolic and diastolic blood pressure and heart rate assessment.\n* Local Cardiac examination. C. Laboratory investigations: Pre-operative (CBC - INR - Urea - Creatinine - Serum Electrolytes K, Na, Mg).\n\nD. Standard 12 lead ECG. E. Echocardiography (TTE): For cardiac dimensions (IVS thickness, right side dimensions, left ventricular end- systolic and diastolic diameters), LV systolic function, degree of tricuspid regurgitation if present and any other structural abnormality detected.\n\nF. LBBAP implantation technique:\n\n-All patients will undergo implantation of permanent pacemaker either single or dual chamber under fluoroscopic guidance according the EHRA procedural recommendations.\n\nG. Intraprocedural 3D-TEE during implantation:\n\n\\- 3D-TEE will facilitate accurate lead positioning through direct visualization of the interventricular septum then the investigators will measure interventricular septum (IVS) length, the angle of lead with the IVS, depth of lead in IVS (the distance from lead tip to the RV subendocardial region), the distance from lead tip to the LV subendocardial region, the distance from the lead tip to tricuspid valve annulus and the distance from the lead tip to RV apex.\n\nH. Electrocardiographic features measured during lead implantation:\n\n* The investigators will measure QRS duration \\& morphology and LVAT duration, notice occurrence of LBB potential and\u002For fixation beats or not, differentiate selective versus non selective pacing during decremental pacing.\n* Also, the investigators will measure lead current of injury COI and impedance during implantation.\n* Calculation of total time of the procedure and fluoroscopic only time.\n\nI. Follow up of the cases:\n\nAfter one week and then after 3months by:\n\n* Assessment of programming parameters (threshold, impendence and sensitivity) and ECG features (V6 RWPT, QRS during\\& morphology).\n* TTE for detection of lead complications, worsening of tricuspid regurgitation and any change of left ventricular function.","ALL","5 Years","18 Years",{"count":71,"type":72},56,"ESTIMATED","INTERVENTIONAL",[23],"* The investigatorse will use the guidance of Intraprocedural three-dimensional transesophageal echocardiography (3D-TEE) for Left Bundle Branch Area Pacing (LBBAP) lead implantation in pediatric patients.\n* This is expected to lead to more procedural efficiency, safe lead positioning and better electrical outcomes, also expected to decrease the lead related complications.",[77],"Left Bundle Branch Area Pacing","NOT_YET_RECRUITING","2026-10-15",{"date":81,"type":82},"2026-10-20","ACTUAL",{"date":84,"type":72},"2026-12",{"date":86,"type":72},"2029-12",{"name":5,"class":6}]