[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100661589":3},{"organization":4,"outcomesModule":7,"designInfo":45,"detailedDescription":44,"studyPopulation":48,"armGroups":49,"interventions":44,"overallOfficials":44,"centralContacts":44,"locations":56,"responsibleParty":105,"collaborators":44,"id":107,"slug":108,"hasResults":109,"nctId":110,"briefTitle":111,"officialTitle":112,"acronym":113,"eligibilityCriteria":114,"healthyVolunteers":109,"sex":115,"minAge":116,"maxAge":44,"enrollmentInfo":117,"targetDuration":44,"studyType":120,"phases":44,"briefSummary":121,"conditions":122,"keywords":126,"overallStatus":131,"whyStopped":44,"lastUpdateSubmitDate":132,"lastUpdatePostDateStruct":133,"startDateStruct":136,"completionDateStruct":138,"leadSponsor":140,"locationsCount":141},{"fullName":5,"class":6},"Nutromics","INDUSTRY",{"primaryOutcomes":8,"secondaryOutcomes":24,"otherOutcomes":44},[9,13,17,21],{"measure":10,"description":11,"timeFrame":12},"Accuracy of Device-measured vancomycin ISF concentration vs. paired serum concentration","Comparison of vancomycin concentration-time profiles and pharmacokinetic parameters (Cmax, Tmax, Cmin, AUC0-24) derived from interstitial fluid (Sensor Device) against paired serum vancomycin immunoassay results.","Up to 5 Days",{"measure":14,"description":15,"timeFrame":16},"Accuracy of Device-measured biomarker (creatinine, C-reactive protein, lactate) ISF concentration vs. paired serum concentration","Determination of accuracy between Device-reported biomarker values and paired serum immunoassay results.","Up to 5 days",{"measure":18,"description":19,"timeFrame":20},"Relationship between ISF analyte concentrations and clinical outcomes","Descriptive summary of association between ISF concentration profiles (vancomycin, creatinine, C-reactive protein, lactate) and 30-day clinical outcomes (discharge\u002Freadmission, morbidity, mortality, treatment-emergent adverse events).","Through 30 days after study completion",{"measure":22,"description":23,"timeFrame":16},"General performance characterisation of the Device","Paired precision between simultaneously worn devices; device accuracy throughout wear duration; electrochemical sensor quality metrics.",[25,28,30,32,34,37,41],{"measure":26,"description":27,"timeFrame":16},"Device performance across patient subgroups","Exploratory analysis of Peak Plasma Concentration (Cmax) by demographic and clinical subgroup (age, sex, ethnicity, BMI, medical conditions\u002Fpathologies).",{"measure":26,"description":29,"timeFrame":16},"Exploratory analysis of Time to Peak Concentration (Tmax) by demographic and clinical subgroup (age, sex, ethnicity, BMI, medical conditions\u002Fpathologies).",{"measure":26,"description":31,"timeFrame":16},"Exploratory analysis of Minimum Blood Plasma Concentration (Cmin) by demographic and clinical subgroup (age, sex, ethnicity, BMI, medical conditions\u002Fpathologies).",{"measure":26,"description":33,"timeFrame":16},"Exploratory analysis of Area Under the Curve (AUC0-24) by demographic and clinical subgroup (age, sex, ethnicity, BMI, medical conditions\u002Fpathologies).",{"measure":35,"description":36,"timeFrame":16},"Stability and precision of the Device over time, compared to standard laboratory assays","Assessment of device reporting accuracy compared to reported values from standard laboratory assays across wear duration, including after 48-hour device replacement.",{"measure":38,"description":39,"timeFrame":40},"Incidence of Adverse Events","Frequency, severity and seriousness of adverse reactions associated with the Device; descriptive summary of application-site photographs.","From first device application to 30 days post study completion",{"measure":42,"description":43,"timeFrame":16},"Accuracy of Device-reported trend toward Acute Kidney Injury (AKI)","Determination of accuracy between Device-reported creatinine trend and serum creatinine; AKI assessed per KDIGO Clinical Practice Guideline for Acute Kidney Injury (2012).",null,{"allocation":44,"interventionModel":44,"interventionModelDescription":44,"primaryPurpose":44,"observationalModel":46,"timePerspective":47,"maskingInfo":44},"COHORT","PROSPECTIVE","Hospitalized participants in the US.",[50,53],{"label":51,"type":44,"description":52,"interventionNames":44},"Cohort 1","Hospitalised participants receiving vancomycin (Vancomycin monitoring)",{"label":54,"type":44,"description":55,"interventionNames":44},"Cohort 2","Hospitalised participants not receiving vancomycin (Biomarker Monitoring)",[57,70,79,87,97],{"facility":58,"status":44,"city":59,"state":60,"zip":61,"country":62,"countryCode":63,"cosmosGeoPoint":64,"geoPoint":69,"contacts":44},"Kaiser Permanente","Oakland","California","94611","United States","US",{"type":65,"coordinates":66},"Point",[67,68],-122.2708,37.80437,{"lat":68,"lon":67},{"facility":71,"status":44,"city":72,"state":60,"zip":73,"country":62,"countryCode":63,"cosmosGeoPoint":74,"geoPoint":78,"contacts":44},"University of California, San Francisco","San Francisco","94143",{"type":65,"coordinates":75},[76,77],-122.41942,37.77493,{"lat":77,"lon":76},{"facility":80,"status":44,"city":80,"state":60,"zip":81,"country":62,"countryCode":63,"cosmosGeoPoint":82,"geoPoint":86,"contacts":44},"Stanford","94305",{"type":65,"coordinates":83},[84,85],-122.16608,37.42411,{"lat":85,"lon":84},{"facility":88,"status":44,"city":89,"state":90,"zip":91,"country":62,"countryCode":63,"cosmosGeoPoint":92,"geoPoint":96,"contacts":44},"Northwell Health","New Hyde Park","New York","11040",{"type":65,"coordinates":93},[94,95],-73.68791,40.7351,{"lat":95,"lon":94},{"facility":98,"status":44,"city":90,"state":90,"zip":99,"country":62,"countryCode":63,"cosmosGeoPoint":100,"geoPoint":104,"contacts":44},"Columbia University","10032",{"type":65,"coordinates":101},[102,103],-74.00597,40.71427,{"lat":103,"lon":102},{"type":106,"investigatorFullName":44,"investigatorTitle":44,"investigatorAffiliation":44,"oldNameTitle":44,"oldOrganization":44},"SPONSOR","100661589","vancomycin-exposure-and-biomarker-tracking-using-real-time-monitoring-of-interstitial-fluid-100661589",false,"NCT07893223","Vancomycin Exposure and Biomarker Tracking Using Real-time Monitoring of Interstitial Fluid","Vancomycin Exposure, Nephrotoxicity, and Sepsis Biomarker Tracking Using Real-time Monitoring of Interstitial Fluid","VENTURE","Inclusion Criteria:\n\n* Capable of providing informed consent OR has a Medical Treatment Decision Maker who can provide informed consent per the informed consent form (ICF).\n* Aged 18 years at time of enrolment.\n* Prescribed vancomycin treatment for intravenous administration (Cohort 1 only); vancomycin treatment duration expected to be ≥48 hours from time of enrolment.\n* Has a central or arterial catheter and\u002For a large-bore cannula, or is willing to have intermittent peripheral blood sampling.\n\nExclusion Criteria:\n\n* Currently receiving an investigational drug or device that, in the Investigator's opinion, may affect participation in this trial.\n* History of allergic reactions to metals, plastics and adhesives which, in the opinion of the Study Investigators, would increase the risk of allergic reaction associated with the Device.\n* Dermatological (or other) condition, or fragile skin, which in the opinion of the Investigators would prevent application of the Nutromics Sensor Device.\n* Severe oedema or local swelling at the intended application site that would likely impair ISF sampling.\n* Immediate life-threatening instability where study procedures would interfere with urgent care (participant may be screened once stable).\n* Pregnant, lactating, planning to become pregnant, breastfeed, or donate ova.","ALL","18 Years",{"count":118,"type":119},200,"ESTIMATED","OBSERVATIONAL","The goal of this observational study is to understand whether a wearable sensor (the Nutromics Sensor Device) can accurately measure drug and biomarker levels in the fluid just under the skin (interstitial fluid), instead of needing repeated blood draws, in adults admitted to hospital who are being treated with the antibiotic vancomycin or who are being monitored for signs of sepsis. The main questions it aims to answer are:\n\n* How closely do interstitial fluid levels of vancomycin match levels measured in the blood at the same time?\n* How closely do interstitial fluid levels of creatinine, C-reactive protein, and lactate (biomarkers linked to kidney function, inflammation, and infection severity) match levels measured in the blood?\n* Can the device pick up on early biomarker trends that signal a patient may be developing acute kidney injury?\n* How well does the device work overall, and does it perform consistently across different patients (by age, sex, ethnicity, body size, and health conditions) and over time?\n* Is the device safe to wear?\n\nThere is no comparison group receiving a different treatment. This study looks at how well the device's readings line up with standard blood tests, not about testing a new treatment.\n\nParticipants will:\n\n* Wear up to two small sensor patches on their upper arm during their hospital stay (up to 5 days), with each patch replaced every 48 hours\n* Have blood samples taken as part of their routine care so results can be compared\n* Have their medical records reviewed 30 days after finishing the study to check on their health outcomes",[123,124,125],"Biomarkers","Acute Kidney Injury","Sepsis",[127,128,123,129,130],"Vancomycin","Wearable Electronic Devices","Interstitial Fluid","Extracellular Fluid","NOT_YET_RECRUITING","2026-10-21",{"date":134,"type":135},"2026-10-23","ACTUAL",{"date":137,"type":119},"2026-12",{"date":139,"type":119},"2028-12",{"name":5,"class":6},5]