[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100660307":3},{"organization":4,"outcomesModule":7,"designInfo":36,"detailedDescription":42,"studyPopulation":35,"armGroups":43,"interventions":56,"overallOfficials":67,"centralContacts":71,"locations":77,"responsibleParty":129,"collaborators":35,"id":132,"slug":133,"hasResults":134,"nctId":135,"briefTitle":136,"officialTitle":137,"acronym":35,"eligibilityCriteria":138,"healthyVolunteers":134,"sex":139,"minAge":140,"maxAge":35,"enrollmentInfo":141,"targetDuration":35,"studyType":144,"phases":145,"briefSummary":147,"conditions":148,"keywords":151,"overallStatus":159,"whyStopped":35,"lastUpdateSubmitDate":160,"lastUpdatePostDateStruct":161,"startDateStruct":164,"completionDateStruct":166,"leadSponsor":168,"locationsCount":169},{"fullName":5,"class":6},"University of Chile","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":27,"otherOutcomes":35},[9,13,17,20,23],{"measure":10,"description":11,"timeFrame":12},"Active Knee Flexion Range of Motion","Active knee flexion range of motion, measured in degrees using a 360° universal goniometer. Three measurements are performed and the average value is recorded.","Preoperative baseline, weekly during postoperative weeks 1-8, and postoperative week 12.",{"measure":14,"description":15,"timeFrame":16},"Passive Knee Flexion Range of Motion","Passive knee flexion range of motion, measured in degrees using a 360° universal goniometer. Three measurements are performed and the average value is recorded.","Preoperative baseline, weekly during postoperative weeks 1-8, and postoperative week 12",{"measure":18,"description":19,"timeFrame":16},"Active Knee Extension Range of Motion","Active knee extension range of motion, measured in degrees using a 360° universal goniometer. Three measurements are performed and the average value is recorded",{"measure":21,"description":22,"timeFrame":16},"Passive Knee Extension Range of Motion","Passive knee extension range of motion, measured in degrees using a 360° universal goniometer. Three measurements are performed and the average value is recorded.",{"measure":24,"description":25,"timeFrame":26},"Isometric Quadriceps Strength","Isometric quadriceps muscle strength of the operated limb, measured in kilograms using a Tindeq dynamometer","Preoperative baseline and postoperative weeks 1, 4, 8, and approximately 12",[28,31],{"measure":29,"description":30,"timeFrame":16},"30-Second Sit-to-Stand Test","Functional performance assessed using the 30-second Sit-to-Stand test. The number of complete sit-to-stand repetitions performed within 30 seconds is recorded",{"measure":32,"description":33,"timeFrame":34},"Usability of the Technology-Assisted Rehabilitation System","Usability of the wearable electrogoniometry-based telerehabilitation system assessed using a structured patient questionnaire. Items were rated on a 5-point Likert scale, with higher scores indicating more favorable usability ratings.","Postoperative week 12",null,{"allocation":37,"interventionModel":38,"interventionModelDescription":35,"primaryPurpose":39,"observationalModel":35,"timePerspective":35,"maskingInfo":40},"RANDOMIZED","PARALLEL","TREATMENT",{"masking":41,"maskingDescription":35,"whoMasked":35},"NONE","Participants are randomly assigned to either the control group or the intervention group. Both groups follow the same standardized home-based rehabilitation exercise program after total knee arthroplasty. Participants assigned to the intervention group additionally use the wearable electrogoniometry-based telerehabilitation system during their rehabilitation exercises.\n\nClinical and functional outcomes are assessed throughout the 12-week postoperative follow-up. Assessments include knee range of motion, functional performance, and isometric quadriceps strength. Isometric quadriceps strength is measured using a Tindeq dynamometer and recorded in kilograms at baseline, postoperative week 1, week 4, week 8, and approximately week 12. Participants also complete self-reported assessments, and participants in the intervention group complete an additional questionnaire evaluating usability and their experience with the technology-assisted rehabilitation system.",[44,50],{"label":45,"type":46,"description":47,"interventionNames":48},"Control group","ACTIVE_COMPARATOR","Participants receive the standard postoperative rehabilitation program after total knee arthroplasty and perform the prescribed home-based exercises without using the wearable telerehabilitation system.",[49],"Behavioral: Standard Home-Based Rehabilitation",{"label":51,"type":52,"description":53,"interventionNames":54},"Wearable Telerehabilitation Group","EXPERIMENTAL","Participants receive the same standard postoperative rehabilitation program and perform the prescribed home-based exercises using the wearable knee device connected to the telerehabilitation application, which provides exercise guidance, real-time feedback, and remote monitoring.",[55,49],"Device: ReBK Wearable Telerehabilitation System",[57,62],{"type":58,"name":59,"description":60,"armGroupLabels":61,"otherNames":35},"DEVICE","ReBK Wearable Telerehabilitation System","Participants use the ReBK wearable telerehabilitation system during prescribed home-based rehabilitation exercises. The system consists of a sensorized knee device connected to a digital application that provides guided exercise, real-time feedback based on knee movement, and remote monitoring of rehabilitation progress.",[51],{"type":63,"name":64,"description":65,"armGroupLabels":66,"otherNames":35},"BEHAVIORAL","Standard Home-Based Rehabilitation","articipants follow the standard postoperative rehabilitation program after total knee arthroplasty and perform the prescribed home-based exercises without using the ReBK wearable telerehabilitation system.",[45,51],[68],{"name":69,"affiliation":5,"role":70},"Hachi Manzur, MD","PRINCIPAL_INVESTIGATOR",[72],{"name":73,"role":74,"phone":75,"phoneExt":35,"email":76},"Macarena A Barahona, PT","CONTACT","+56999054293","maca.b.v@gmail.com",[78,96,112],{"facility":79,"status":35,"city":80,"state":81,"zip":82,"country":83,"countryCode":84,"cosmosGeoPoint":85,"geoPoint":90,"contacts":91},"Hospital Dr. Franco Ravera Zunino","Rancagua","Región del Libertador General Bernardo O’Higgins","rancagua","Chile","CL",{"type":86,"coordinates":87},"Point",[88,89],-70.74053,-34.1691,{"lat":89,"lon":88},[92],{"name":93,"role":74,"phone":94,"phoneExt":35,"email":95},"Nicolas Jabes, MD","997595606","dr.nicolas.jabes@gmail.com",{"facility":97,"status":35,"city":98,"state":99,"zip":100,"country":83,"countryCode":84,"cosmosGeoPoint":101,"geoPoint":105,"contacts":106},"Hospital Clinico Universidad de Chile","Santiago","Santiago Metropolitan","santiago",{"type":86,"coordinates":102},[103,104],-70.64827,-33.45694,{"lat":104,"lon":103},[107,108,109],{"name":73,"role":74,"phone":75,"phoneExt":35,"email":76},{"name":69,"role":70,"phone":35,"phoneExt":35,"email":35},{"name":110,"role":111,"phone":35,"phoneExt":35,"email":35},"Maximiliano Barahona, MD","SUB_INVESTIGATOR",{"facility":113,"status":35,"city":114,"state":35,"zip":35,"country":83,"countryCode":84,"cosmosGeoPoint":115,"geoPoint":119,"contacts":120},"Hospital Las Higueras de Talcahuano","Talcahuano",{"type":86,"coordinates":116},[117,118],-73.11684,-36.72494,{"lat":118,"lon":117},[121,125],{"name":122,"role":74,"phone":123,"phoneExt":35,"email":124},"Francisco Urrizola","+56992997832","urrizola@gmail.com",{"name":126,"role":74,"phone":127,"phoneExt":35,"email":128},"Nelson Morales","+56974081638","dr.nmorales.rodilla@gmail.com",{"type":70,"investigatorFullName":130,"investigatorTitle":131,"investigatorAffiliation":5,"oldNameTitle":35,"oldOrganization":35},"maximiliano barahona vasquez","Co-Investigator","100660307","wearable-knee-assisted-rehabilitation-for-range-of-motion-and-muscle-strength-after-total-knee-arthroplasty-100660307",false,"NCT07875725","Wearable Knee-Assisted Rehabilitation for Range of Motion and Muscle Strength After Total Knee Arthroplasty","Wearable Knee-Assisted Rehabilitation to Improve Range of Motion and Muscle Strength During Early Recovery After Total Knee Arthroplasty: A Randomized Controlled Trial","Inclusion Criteria:\n\n* Adults older than 60 years scheduled for primary total knee arthroplasty for knee osteoarthritis.\n* Ability to attend postoperative follow-up assessments.\n\nExclusion Criteria:\n\n* Revision arthroplasty.\n* Use of constrained implants.\n* Cognitive impairment preventing adherence to rehabilitation instructions.\n* Inability to participate in follow-up assessments.","ALL","60 Years",{"count":142,"type":143},80,"ESTIMATED","INTERVENTIONAL",[146],"NA","This randomized controlled trial evaluates a wearable electrogoniometry-based telerehabilitation system designed to support recovery after total knee arthroplasty. Participants follow the same home-based rehabilitation exercise program and are randomly assigned to an intervention or control group. Participants in the intervention group additionally use a wearable knee device connected to a digital application that provides guidance and real-time feedback during exercise and allows remote monitoring of rehabilitation. Knee range of motion, functional performance, and isometric quadriceps strength are assessed before surgery and during the 12-week postoperative follow-up. The study compares recovery between patients using the technology-assisted rehabilitation system and those following the conventional home-based rehabilitation program.",[149,150],"Total Knee Arthroplasty Recovery","Knee Osteoarthritis",[152,153,154,155,156,157,158],"Telerehabilitation","Total Knee Arthroplasty","Wearable Technology","Electrogoniometry","Range of Motion","Quadriceps Strength","Home-Based Rehabilitation","NOT_YET_RECRUITING","2026-10-08",{"date":162,"type":163},"2026-10-15","ACTUAL",{"date":165,"type":143},"2026-09-21",{"date":167,"type":143},"2027-09-30",{"name":5,"class":6},3]