[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100666831":3},{"organization":4,"outcomesModule":7,"designInfo":38,"detailedDescription":40,"studyPopulation":41,"armGroups":42,"interventions":52,"overallOfficials":33,"centralContacts":58,"locations":64,"responsibleParty":122,"collaborators":33,"id":125,"slug":126,"hasResults":127,"nctId":128,"briefTitle":129,"officialTitle":130,"acronym":33,"eligibilityCriteria":131,"healthyVolunteers":132,"sex":133,"minAge":134,"maxAge":33,"enrollmentInfo":135,"targetDuration":138,"studyType":139,"phases":33,"briefSummary":140,"conditions":141,"keywords":33,"overallStatus":66,"whyStopped":33,"lastUpdateSubmitDate":148,"lastUpdatePostDateStruct":149,"startDateStruct":152,"completionDateStruct":154,"leadSponsor":156,"locationsCount":157},{"fullName":5,"class":6},"Beijing Anzhen Hospital","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":33,"otherOutcomes":34},[9,13,17,20,24,27,30],{"measure":10,"description":11,"timeFrame":12},"Diagnostic performance for VHD","Diagnostic performance of the ECG-PCG model for detecting moderate or greater VHD will be assessed using the area under the receiver operating characteristic curve (AUROC), with concurrent echocardiography as the reference standard.\n\nVHD types include aortic stenosis, aortic regurgitation, mitral stenosis, mitral regurgitation, and tricuspid regurgitation.","Baseline",{"measure":14,"description":15,"timeFrame":16},"Predictive performance for prosthetic valve dysfunction","AUROC of an ECG-PCG model to predict new-onset prosthetic valve dysfunction, using concurrent echocardiography as the reference standard.","From the procedure through 12 months postprocedure",{"measure":18,"description":19,"timeFrame":16},"Diagnostic performance for paravalvular regurgitation","AUROC for ECG-PCG-based detection of moderate or greater paravalvular regurgitation, using concurrent echocardiography as the reference standard.",{"measure":21,"description":22,"timeFrame":23},"Predictive performance for conduction block after TAVR","AUROC of an ECG-PCG model using baseline recordings to predict new-onset atrioventricular or bundle branch block after transcatheter aortic valve replacement. A positive outcome is defined as the occurrence of qualifying conduction block, documented by conventional ECG or cardiac rhythm monitoring.","From the procedure to hospital discharge, assessed up to 7 days",{"measure":25,"description":26,"timeFrame":16},"Predictive performance for recurrent valvular regurgitation","AUROC of an ECG-PCG model to predict recurrent moderate or greater (≥2+) regurgitation of the treated valve, using concurrent echocardiography as the reference standard.",{"measure":28,"description":29,"timeFrame":16},"Association of ECG-PCG features with LVEF","Correlation coefficient between ECG-PCG features and left ventricular ejection fraction (LVEF) measured by concurrent echocardiography.",{"measure":31,"description":32,"timeFrame":16},"Association of ECG-PCG features with LV diastolic function","Correlation coefficient betweenECG-PCG features and LV diastolic function measured by concurrent echocardiography.",null,[35],{"measure":36,"description":37,"timeFrame":16},"Predictive performance for clinical outcomes","Performance of ECG-PCG models for subsequent clinical events, including death, heart failure rehospitalization, stroke, and leaflet thrombosis.",{"allocation":33,"interventionModel":33,"interventionModelDescription":33,"primaryPurpose":33,"observationalModel":39,"timePerspective":6,"maskingInfo":33},"COHORT","Echocardiography is the standard imaging modality for the assessment of valvular heart disease (VHD). However, the limited availability of echocardiography in community makes it difficult to fully meet the needs of screening, frequent reassessment, and long-term follow-up. Wearable synchronous electrocardiogram-phonocardiogram (ECG-PCG) technology records cardiac electrical activity and heart sounds simultaneously, and may offer an alternative to echocardiography for VHD assessment.\n\nThis multicenter study uses an ambispective cohort design and includes adults with VHD and controls. The prospective cohort includes participants enrolled after July 2026. ECG-PCG recordings, concurrent echocardiographic data, conventional 12-lead ECG findings, and clinical characteristics will be obtained from existing records or collected prospectively using standardized procedures.\n\nFor patients undergoing transcatheter or surgical valve intervention, data will be collected at baseline, postoperatively, at hospital discharge, and at 1, 6, and 12 months after the procedure, with longer-term follow-up as needed.\n\nThe diagnostic performance of ECG-PCG models will be assessed using echocardiography as the reference standard for VHD. Associations of ECG-PCG features with cardiac structure and function, conventional ECG parameters, and clinical characteristics will also be examined. Perioperative analyses will evaluate ECG-PCG models for detecting and predicting conduction abnormalities, early postoperative valvular dysfunction, and clinical events. Follow-up analyses will assess ECG-PCG features as predictors of changes in cardiac and valvular function and subsequent clinical events.\n\nExploratory ECG-PCG models will also be developed for the identification of heart failure, characterization of postoperative recovery trajectories, and other applications in VHD and structural heart disease.","Adults undergoing concurrent ECG-PCG recording and echocardiography at participating centers",[43,48],{"label":44,"type":33,"description":45,"interventionNames":46},"Retrospective cohort","Adults with existing paired ECG-PCG and echocardiographic assessments.",[47],"Diagnostic Test: wearable synchronous electrocardiogram-phonocardiogram",{"label":49,"type":33,"description":50,"interventionNames":51},"Prospective cohort","Consecutively enrolled adults with valvular heart disease and control participants undergoing paired ECG-PCG and echocardiographic assessment.",[47],[53],{"type":54,"name":55,"description":56,"armGroupLabels":57,"otherNames":33},"DIAGNOSTIC_TEST","wearable synchronous electrocardiogram-phonocardiogram","Cardiac electrical activity and heart sounds are recorded simultaneously and noninvasively using a wearable synchronous electrocardiogram-phonocardiogram device.",[49,44],[59],{"name":60,"role":61,"phone":62,"phoneExt":33,"email":63},"Song","CONTACT","+86 13801120805","songgy_anzhen@vip.163.com",[65,80,90,100,110],{"facility":5,"status":66,"city":67,"state":68,"zip":33,"country":69,"countryCode":70,"cosmosGeoPoint":71,"geoPoint":76,"contacts":77},"RECRUITING","Beijing","Beijing Municipality","China","CN",{"type":72,"coordinates":73},"Point",[74,75],116.39723,39.9075,{"lat":75,"lon":74},[78],{"name":79,"role":61,"phone":62,"phoneExt":33,"email":63},"Guangyuan Song",{"facility":5,"status":66,"city":81,"state":82,"zip":33,"country":69,"countryCode":70,"cosmosGeoPoint":83,"geoPoint":87,"contacts":88},"Luoyang","Henan",{"type":72,"coordinates":84},[85,86],112.43684,34.67345,{"lat":86,"lon":85},[89],{"name":79,"role":61,"phone":62,"phoneExt":33,"email":63},{"facility":5,"status":66,"city":91,"state":92,"zip":33,"country":69,"countryCode":70,"cosmosGeoPoint":93,"geoPoint":97,"contacts":98},"Changshu","Jiangsu",{"type":72,"coordinates":94},[95,96],120.74221,31.64615,{"lat":96,"lon":95},[99],{"name":79,"role":61,"phone":62,"phoneExt":33,"email":63},{"facility":5,"status":66,"city":101,"state":102,"zip":33,"country":69,"countryCode":70,"cosmosGeoPoint":103,"geoPoint":107,"contacts":108},"Jinan","Shandong",{"type":72,"coordinates":104},[105,106],116.99722,36.66833,{"lat":106,"lon":105},[109],{"name":79,"role":61,"phone":62,"phoneExt":33,"email":63},{"facility":111,"status":66,"city":112,"state":113,"zip":33,"country":69,"countryCode":70,"cosmosGeoPoint":114,"geoPoint":118,"contacts":119},"Ruijin Hospital, Shanghai Jiao Tong University School of Medicine","Shanghai","Shanghai Municipality",{"type":72,"coordinates":115},[116,117],121.45806,31.22222,{"lat":117,"lon":116},[120],{"name":121,"role":61,"phone":33,"phoneExt":33,"email":33},"Zhengbin Zhu",{"type":123,"investigatorFullName":79,"investigatorTitle":124,"investigatorAffiliation":5,"oldNameTitle":33,"oldOrganization":33},"PRINCIPAL_INVESTIGATOR","Professor","100666831","wearable-synchronous-electrocardiogram-phonocardiogram-for-diagnosis-perioperative-assessment-and-follow-up-of-valvular-heart-disease-100666831",false,"NCT07963371","Wearable Synchronous Electrocardiogram-Phonocardiogram for Diagnosis, Perioperative Assessment, and Follow-up of Valvular Heart Disease","Wearable Synchronous Electrocardiogram-Phonocardiogram for Diagnosis, Perioperative Assessment, and Follow-up of Valvular Heart Disease: A Multicenter Cohort Study","Inclusion Criteria:\n\n* Age 18 years or older.\n* ECG-PCG recording and echocardiography during the same clinical assessment period.\n* Written informed consent for prospectively enrolled participants.\n\nExclusion Criteria:\n\n* Unwillingness or inability to complete study procedures.\n* ECG-PCG acquisition cannot be completed, or the original signals are unsuitable for analysis after quality control.\n* Missing data required for ECG-PCG analysis.",true,"ALL","18 Years",{"count":136,"type":137},20000,"ESTIMATED","12 Months","OBSERVATIONAL","This multicenter cohort study aims to evaluate the clinical value of wearable synchronous electrocardiogram-phonocardiogram recordings for valvular heart disease (VHD) diagnosis, perioperative assessment, and postoperative follow-up. Echocardiography will serve as the reference standard for VHD assessment.",[142,143,144,145,146,147],"Valvular Heart Disease","Aortic Stenosis","Aortic Regurgitation","Mitral Stenosis","Mitral Regurgitation","Tricuspid Regurgitation","2026-11-24",{"date":150,"type":151},"2026-11-27","ACTUAL",{"date":153,"type":151},"2026-07-20",{"date":155,"type":137},"2031-12-31",{"name":5,"class":6},5]