[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100660555":3},{"organization":4,"outcomesModule":7,"designInfo":34,"detailedDescription":37,"studyPopulation":38,"armGroups":39,"interventions":53,"overallOfficials":33,"centralContacts":59,"locations":69,"responsibleParty":134,"collaborators":33,"id":138,"slug":139,"hasResults":140,"nctId":141,"briefTitle":142,"officialTitle":143,"acronym":144,"eligibilityCriteria":145,"healthyVolunteers":140,"sex":146,"minAge":147,"maxAge":33,"enrollmentInfo":148,"targetDuration":33,"studyType":151,"phases":33,"briefSummary":152,"conditions":153,"keywords":157,"overallStatus":166,"whyStopped":33,"lastUpdateSubmitDate":167,"lastUpdatePostDateStruct":168,"startDateStruct":171,"completionDateStruct":173,"leadSponsor":175,"locationsCount":176},{"fullName":5,"class":6},"University Hospital Muenster","OTHER",{"primaryOutcomes":8,"secondaryOutcomes":13,"otherOutcomes":33},[9],{"measure":10,"description":11,"timeFrame":12},"Within-session repeatability coefficient of EUS-PPG measured by the same expert operator","The repeatability coefficient will be calculated as 2.77 multiplied by the within-subject standard deviation of paired EUS-PPG measurements in the same-expert group. It will be reported in mmHg and as a percentage of the cohort mean, with a 95% confidence interval.","During the index EUS-PPG procedure",[14,17,20,23,26,29],{"measure":15,"description":16,"timeFrame":12},"Inter-operator reproducibility coefficient of EUS-PPG","The reproducibility coefficient will be estimated from paired EUS-PPG differences when different operators perform the two measurement sets and will be reported in mmHg and as a percentage, with a 95% confidence interval.",{"measure":18,"description":19,"timeFrame":12},"Variance components of repeated EUS-PPG measurements","A mixed-effects model using all individual readings will estimate patient-, procedure-list-, operator-, measurement-set-, and reading-level variance components.",{"measure":21,"description":22,"timeFrame":12},"Intraclass correlation coefficient for paired EUS-PPG measurements","Two-way absolute-agreement intraclass correlation coefficients will be reported overall and by operator configuration with 95% confidence intervals.",{"measure":24,"description":25,"timeFrame":12},"Bland-Altman agreement of paired EUS-PPG measurements","Bias and 95% limits of agreement will be calculated overall and separately by operator pairing.",{"measure":27,"description":28,"timeFrame":12},"Discordant classification at portal pressure gradient thresholds of 10 mmHg and 12 mmHg","The proportion of participants whose classification crosses the 10-mmHg or 12-mmHg threshold between the two measurement sets will be reported.",{"measure":30,"description":31,"timeFrame":32},"Procedure-associated adverse events","Adverse events will include bleeding, pain, hemoglobin decrease, sedation-related events, unplanned admission or prolongation of stay, transfusion, and unplanned intervention.","From the index procedure through 30 days",null,{"allocation":33,"interventionModel":33,"interventionModelDescription":33,"primaryPurpose":33,"observationalModel":35,"timePerspective":36,"maskingInfo":33},"COHORT","PROSPECTIVE","Consecutive adults with an independently established clinical indication for EUS-PPG will be enrolled at five centres. The clinically indicated first measurement will be followed by a research-only second complete measurement set during the same sedation episode, without an intervention between sets. After the first set, the system will be flushed, the needle withdrawn from the liver, the system recalibrated, and the portal and hepatic veins punctured again for fresh triplicate readings. The interval between sets is targeted at 10 minutes or less. Two techniques of withdrawal are allowed. One technique includes transcapsular re-puncture. The needle is flushed and fully retracted from the liver. The other technique includes subcapsular retraction. The needle is flushed and withdrawn into the liver parenchyma to a position immediately beneath the capsule, without crossing it, so that no further capsular puncture is performed. Procedure lists will be cluster-randomised according to examination lists to one of three operator configurations: the same expert performs both sets, two different experts perform the sets, or an expert and a trainee under supervision perform the sets. The order within each pair will be randomised. Clinical decisions will be based exclusively on the first measurement set. Participants will undergo safety follow-up through day 30.","Consecutive adult patients with an independently established clinical indication for EUS-guided portal pressure gradient measurement, including patients with and without clinically significant portal hypertension.",[40,45,49],{"label":41,"type":33,"description":42,"interventionNames":43},"Same expert operator","Both complete measurement sets are performed by the same expert operator.",[44],"Diagnostic Test: Repeated EUS-Guided Portal Pressure Gradient Measurement",{"label":46,"type":33,"description":47,"interventionNames":48},"Two expert operators","The two complete measurement sets are performed by two different expert operators, with order randomised.",[44],{"label":50,"type":33,"description":51,"interventionNames":52},"Expert and trainee operators","One complete measurement set is performed by an expert and the other by a trainee under direct supervision, with order randomised.",[44],[54],{"type":55,"name":56,"description":57,"armGroupLabels":58,"otherNames":33},"DIAGNOSTIC_TEST","Repeated EUS-Guided Portal Pressure Gradient Measurement","During a clinically indicated EUS-PPG procedure, each participant undergoes a second complete EUS-PPG measurement set in the same session. For each set, pressures in a hepatic vein and an intrahepatic portal vein branch are measured in triplicate using the same 22-gauge measurement chain. Before the repeat set, the system is flushed, the needle is withdrawn with one of the allowed techniques, the transducer is recalibrated, and the target vessels are independently re-identified and punctured. No treatment or portal-pressure-altering intervention occurs between the two sets.",[50,41,46],[60,65],{"name":61,"role":62,"phone":63,"phoneExt":33,"email":64},"Michael Praktiknjo, MD PhD","CONTACT","+49 251 83 44826","michael.praktiknjo@ukmuenster.de",{"name":66,"role":62,"phone":67,"phoneExt":33,"email":68},"Dominik van de Loo, MD","+49 251 83 44476","dominikjulian.vandeloo@ukmuenster.de",[70,84,98,106,119],{"facility":71,"status":33,"city":72,"state":33,"zip":33,"country":73,"countryCode":74,"cosmosGeoPoint":75,"geoPoint":80,"contacts":81},"UZ Leuven","Leuven","Belgium","BE",{"type":76,"coordinates":77},"Point",[78,79],4.70093,50.87959,{"lat":79,"lon":78},[82],{"name":83,"role":62,"phone":33,"phoneExt":33,"email":33},"Wim Laleman, MD PhD",{"facility":85,"status":33,"city":86,"state":87,"zip":33,"country":88,"countryCode":89,"cosmosGeoPoint":90,"geoPoint":94,"contacts":95},"Centre hospitalier de l'Université de Montréal (CHUM)","Montreal","Quebec","Canada","CA",{"type":76,"coordinates":91},[92,93],-73.58781,45.50884,{"lat":93,"lon":92},[96],{"name":97,"role":62,"phone":33,"phoneExt":33,"email":33},"Philippe Willems, MD",{"facility":99,"status":33,"city":86,"state":87,"zip":33,"country":88,"countryCode":89,"cosmosGeoPoint":100,"geoPoint":102,"contacts":103},"McGill University Health Centre",{"type":76,"coordinates":101},[92,93],{"lat":93,"lon":92},[104],{"name":105,"role":62,"phone":33,"phoneExt":33,"email":33},"Amine Benmassaoud, MD",{"facility":5,"status":33,"city":107,"state":108,"zip":109,"country":110,"countryCode":111,"cosmosGeoPoint":112,"geoPoint":116,"contacts":117},"Münster","North Rhine-Westphalia","48149","Germany","DE",{"type":76,"coordinates":113},[114,115],7.62571,51.96236,{"lat":115,"lon":114},[118],{"name":61,"role":62,"phone":63,"phoneExt":33,"email":64},{"facility":120,"status":33,"city":121,"state":122,"zip":123,"country":124,"countryCode":125,"cosmosGeoPoint":126,"geoPoint":130,"contacts":131},"Fondazione Policlinico Universitario Agostino Gemelli IRCCS","Rome","Lazio","00168","Italy","IT",{"type":76,"coordinates":127},[128,129],12.51133,41.89193,{"lat":129,"lon":128},[132],{"name":133,"role":62,"phone":33,"phoneExt":33,"email":33},"Francesco Santoapolo, MD",{"type":135,"investigatorFullName":136,"investigatorTitle":137,"investigatorAffiliation":5,"oldNameTitle":33,"oldOrganization":33},"PRINCIPAL_INVESTIGATOR","Prof. Dr. Michael Praktiknjo","Professor of Hepatology","100660555","within-session-repeatability-of-eus-guided-portal-pressure-gradient-measurement-100660555",false,"NCT07877298","Within-Session Repeatability of EUS-Guided Portal Pressure Gradient Measurement","Within-Session Repeatability and Inter-Operator Reproducibility of EUS-Guided Portal Pressure Gradient Measurement: A Prospective Multicentre Study","REPEAT-PPG","Inclusion Criteria:\n\n* Age 18 years or older\n* Clinical indication for EUS-guided portal pressure gradient measurement established independently of the study\n* Written informed consent, including consent for the additional measurement set\n\nExclusion Criteria:\n\n* Contraindication to endoscopy, sedation, or endosonography-guided vascular puncture\n* Non-correctable coagulation disorder\n* Hemodynamic instability at the time of the procedure\n* Any intervention between the two measurement sets that may alter portal pressure, including fluid administration beyond maintenance requirements, vasoactive substances, paracentesis, or variceal band ligation\n* Technically non-evaluable first measurement set\n* Pregnancy or breastfeeding\n* Inability to provide informed consent","ALL","18 Years",{"count":149,"type":150},150,"ESTIMATED","OBSERVATIONAL","This prospective multicentre observational reliability study will determine how much a repeated endoscopic ultrasound-guided portal pressure gradient (EUS-PPG) measurement differs from the first measurement in the same patient during the same procedural session. Each participant will undergo two complete EUS-PPG measurement sets using an identical 22-gauge measurement setup. The study will quantify within-session repeatability when the same expert performs both sets and inter-operator reproducibility when different operators perform the sets.",[154,155,156],"Portal Hypertension","Chronic Liver Disease","Liver Cirrhosis",[158,159,160,161,162,163,164,165],"EUS-PPG","Endoscopic ultrasound","Portal pressure gradient","Portal hypertension","Repeatability","Reproducibility","Bland-Altman analysis","Intraclass correlation coefficient","NOT_YET_RECRUITING","2026-11-12",{"date":169,"type":170},"2026-11-13","ACTUAL",{"date":172,"type":150},"2027-01-01",{"date":174,"type":150},"2028-10-01",{"name":5,"class":6},5]