[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-studies-list:{\"overallStatus\":[\"RECRUITING\",\"AVAILABLE\",\"NOT_YET_RECRUITING\"],\"leadSponsorName\":\"NIRSense Inc.\",\"orderBy\":\"LastUpdateSubmitDate:desc\",\"size\":25,\"offset\":0}":3,"health-study-condition:":49},{"pageToken":4,"total":5,"offset":6,"count":5,"results":7},null,1,0,[8],{"id":9,"slug":10,"hasResults":11,"nctId":12,"briefTitle":13,"officialTitle":14,"acronym":4,"eligibilityCriteria":15,"healthyVolunteers":11,"sex":16,"minAge":17,"maxAge":4,"enrollmentInfo":18,"targetDuration":4,"studyType":21,"phases":4,"briefSummary":22,"conditions":23,"keywords":27,"overallStatus":37,"whyStopped":4,"lastUpdateSubmitDate":38,"lastUpdatePostDateStruct":39,"startDateStruct":42,"completionDateStruct":44,"leadSponsor":46,"locationsCount":5},"100656417","clinical-evaluation-of-nirsense-tissue-oximetry-sensor-monitoring-to-early-detect-cardiogenic-shock-100656417",false,"NCT07825363","Clinical Evaluation of NIRSense Tissue Oximetry Sensor Monitoring to Early Detect Cardiogenic Shock","Clinical Evaluation of Using NIRSense Sensor Patch to Measure Microvascular Perfusion Responses and Predict Decompensation in Cardiogenic Shock Patients","Inclusion Criteria:\n\n* Acutely decompensated symptomatic heart failure (HF) documented by: (a) symptoms of HF requiring current treatment; (b) Society for Cardiovascular Angiography and Interventions (SCAI) stage B, C, or D; and (c) hospital admission with HF as the primary or secondary diagnosis; OR acute myocardial infarction (MI) patient undergoing coronary angiography\n* Admitted to the intensive care unit and currently in SCAI stage B, C, or D\n* Age 18 years or older\n* Weight greater than 40 kg\n\nExclusion Criteria:\n\n* Prior known severe allergy to medical-grade adhesive or tape (self-reported)\n* Currently participating in an investigational drug or device study that would interfere with the conduct or results of this study. Trials requiring extended follow-up for products that were investigational but have since become commercially available are not considered investigational.\n* The investigator believes the participant is not an appropriate candidate for the study","ALL","18 Years",{"count":19,"type":20},20,"ESTIMATED","OBSERVATIONAL","This is a prospective, single-center, observational pilot study of the investigational NIRSense Tissue Oximetry Sensor System (Envello Core), a noninvasive wearable sensor patch that uses near-infrared spectroscopy (NIRS) and photoplethysmography (PPG), combined with an electrocardiography\u002Fimpedance cardiography (ECG\u002FICG) sensor, to continuously monitor tissue oxygen saturation (StO2), peripheral oxygen saturation (SpO2), pulse rate, respiratory rate, stroke volume, and related metrics. Up to 20 adults admitted to the Cleveland Clinic Florida cardiac intensive care unit with acute myocardial infarction or acute decompensated heart failure and in Society for Cardiovascular Angiography and Interventions (SCAI) shock stage B, C, or D will wear the sensors on the sternum, forearm, and other locations for approximately 24 to 72 hours during standard care. Sensor data will be compared with standard-of-care hemodynamic and laboratory measurements and with the patient's clinical course to evaluate the feasibility of the device, the correlation of its measurements with established clinical parameters, and its potential to detect deterioration in SCAI shock stage earlier. No treatment decisions are made based on the study device.",[24,25,26],"Cardiogenic Shock","Acute Myocardial Infarction","Acute Decompensated Heart Failure",[28,29,30,31,32,33,34,35,36],"near-infrared spectroscopy","photoplethysmography","impedance cardiography","tissue oxygen saturation","perfusion index","microcirculation","wearable sensor","noninvasive hemodynamic monitoring","SCAI shock stage","RECRUITING","2026-09-13",{"date":40,"type":41},"2026-09-17","ACTUAL",{"date":43,"type":41},"2025-06-17",{"date":45,"type":20},"2027-08",{"name":47,"class":48},"NIRSense Inc.","INDUSTRY",""]