[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-studies-list:{\"conditionNormalized\":\"cardiac-pacemaker-artificial\",\"overallStatus\":[\"RECRUITING\",\"AVAILABLE\",\"NOT_YET_RECRUITING\"],\"orderBy\":\"LastUpdateSubmitDate:desc\",\"size\":25,\"offset\":0}":3,"health-study-condition:cardiac-pacemaker-artificial":26},{"pageToken":4,"total":5,"offset":6,"count":5,"results":7},null,1,0,[8],{"id":9,"slug":10,"hasResults":11,"nctId":12,"briefTitle":13,"officialTitle":14,"acronym":4,"eligibilityCriteria":15,"healthyVolunteers":11,"sex":16,"minAge":17,"maxAge":4,"enrollmentInfo":18,"targetDuration":4,"studyType":21,"phases":22,"briefSummary":24,"conditions":25,"keywords":30,"overallStatus":37,"whyStopped":4,"lastUpdateSubmitDate":38,"lastUpdatePostDateStruct":39,"startDateStruct":42,"completionDateStruct":44,"leadSponsor":46,"locationsCount":5},"100664817","leap-csp-ide-study-100664817",false,"NCT07935551","LEAP CSP IDE Study","LEadless Advanced Pacing Conduction System Pacing IDE Study","Inclusion Criteria:\n\n1. Subject must have at least one standard pacemaker indication in adherence with ACC\u002FAHA\u002FHRS\u002FESC bradycardia pacing guidelines\n2. Subject must be at least 18 years of age or the legal age, whichever age is greater\n3. Subject has life expectancy of at least 2 years\n4. Subject is willing to comply with clinical investigation procedures and agrees to return to clinic or participate in remote visits, as applicable, for all required follow-up visits, tests, and exams\n5. Subject has been informed of the nature of the clinical investigation, agrees to its provisions and has provided a signed written informed consent, as approved by the local IRB\u002FEC\n\nExclusion Criteria:\n\n1. Subject has a mechanical tricuspid valve, percutaneous tricuspid valve repair or replacement, or any implanted vena cava filter\n2. Subject has evidence of tricuspid stenosis, tricuspid atresia, or presence of any condition that precludes appropriate vascular access for the study procedure\n3. Subject has pre-existing, permanent endocardial pacing or defibrillation leads or any devices in the right heart or interventricular septum\n4. Subject has an active implantable electronic device that cannot be turned off during the study procedure\n5. Subject has had a permanent endocardial pacing or defibrillation lead or leadless pacemaker removed within 24 hours prior to enrollment\n6. Subject is scheduled for an atrioventricular (AV) nodal or AV junctional ablation procedure during the AVEIR CSP LP implantation and 90 days post-implant\n7. Subject is indicated for an ICD, CRT-P, or CRT-D device\n8. Subject has known allergy or hypersensitivity to \\\u003C 1 mg of dexamethasone sodium phosphate or any blood or tissue contacting material used in the study procedure\n9. Subject is unable to receive heparin or an acceptable alternative to achieve adequate anticoagulation\n10. Subject has an active systemic infection\n11. Subject has known history or repair of a ventricular septal defect\n12. Subject is currently participating in another clinical investigation that might impact the outcomes of the clinical investigation\n13. Pregnant or nursing subjects and those who plan pregnancy during the clinical investigation follow-up period\n14. Subject has presence of anatomic or comorbid conditions, or other medical, social, or psychological conditions that, in the investigator's opinion, could confound the assessment of the investigational device and\u002For implant procedure, limit the subject's ability to participate in the clinical investigation or to comply with the follow-up requirements of the clinical investigation\n15. Subject is unable to read or write","ALL","18 Years",{"count":19,"type":20},375,"ESTIMATED","INTERVENTIONAL",[23],"NA","The goal of this clinical study is to learn if the AVEIR CSP Leadless Pacemaker System is safe and works to treat adults with slow heart rhythms or irregular heartbeats. The main questions the study aims to answer are:\n\nWhat medical problems do participants have after being implanted with the AVEIR CSP System for 3 months?\n\nDoes the AVEIR CSP System pace and sense the heart effectively after 3 months?\n\nParticipants will be implanted with the AVEIR CSP System and will be asked to return to or call the clinic periodically to report their symptoms. Participants will also complete two short questionnaires describing how their quality of life has changed.\n\nResearchers will adjust the settings of the implanted device through a special programmer, as needed, and will check the participants' heart rhythm through an electrocardiogram. Researchers will also check on the device's implant location using a chest x-ray and evaluate the participants' heart function using an echocardiogram.",[26,27,28,29],"Cardiac Pacemaker, Artificial","Cardiac Rhythm Disorder","Bradycardia","Cardiac Pacemaker",[28,31,32,33,34,35,36],"Sick Sinus Syndrome","Pacemaker","Leadless","Conduction System Pacing","Physiologic Pacing","LBBAP","RECRUITING","2026-11-23",{"date":40,"type":41},"2026-11-24","ACTUAL",{"date":43,"type":41},"2026-11-19",{"date":45,"type":20},"2030-07-30",{"name":47,"class":48},"Abbott Medical Devices","INDUSTRY"]