[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-studies-list:{\"conditionNormalized\":\"mandibular-angle-fractures\",\"overallStatus\":[\"RECRUITING\",\"AVAILABLE\",\"NOT_YET_RECRUITING\"],\"orderBy\":\"LastUpdateSubmitDate:desc\",\"size\":25,\"offset\":0}":3,"health-study-condition:mandibular-angle-fractures":25},{"pageToken":4,"total":5,"offset":6,"count":5,"results":7},null,2,0,[8,41],{"id":9,"slug":10,"hasResults":11,"nctId":12,"briefTitle":13,"officialTitle":13,"acronym":4,"eligibilityCriteria":14,"healthyVolunteers":11,"sex":15,"minAge":16,"maxAge":4,"enrollmentInfo":17,"targetDuration":4,"studyType":20,"phases":21,"briefSummary":23,"conditions":24,"keywords":26,"overallStatus":28,"whyStopped":4,"lastUpdateSubmitDate":29,"lastUpdatePostDateStruct":30,"startDateStruct":33,"completionDateStruct":35,"leadSponsor":37,"locationsCount":40},"100666684","clinical-and-biomechanical-evaluation-of-a-modified-custom-made-double-t-titanium-miniplate-for-fixation-of-mandibular-angle-fractures-100666684",false,"NCT07958600","Clinical and Biomechanical Evaluation of a Modified Custom-Made Double T Titanium Miniplate for Fixation of Mandibular Angle Fractures","Inclusion Criteria:\n\n* Adult dentate patients aged 21 years or older.\n* Non-comminuted mandibular angle fracture indicated for open reduction and internal fixation (ORIF).\n* Adequate occlusal stability or correctable occlusion after fracture reduction.\n* Ability and willingness to attend all scheduled postoperative follow-up visits (1 week, 1 month, 3 months, and 6 months).\n* Willingness to provide written informed consent.\n\nExclusion Criteria:\n\n* Comminuted mandibular angle fractures or pathological fractures.\n* Edentulous mandible or severely periodontally compromised molars in the fixation zone.\n* Medically compromised patients contraindicating surgical intervention or general anesthesia.\n* Patients presenting with infected mandibular fractures.\n* Patients with malunion fractures.\n* Patients with bone gap defects resulting from gunshot wounds.","ALL","21 Years",{"count":18,"type":19},16,"ESTIMATED","INTERVENTIONAL",[22],"NA","Mandibular angle fractures are among the most common and biomechanically challenging maxillofacial injuries due to complex muscular forces and proximity to dental roots. While conventional two-miniplate fixation provides reliable stability, it increases hardware bulk, periosteal stripping, and the risk of iatrogenic injury to adjacent molar roots.\n\nThis randomized controlled clinical trial aims to evaluate the clinical and biomechanical performance of a modified custom-made double T titanium miniplate compared to conventional two-miniplate fixation in the management of mandibular angle fractures. Sixteen adult patients with non-comminuted mandibular angle fractures will be randomly assigned into two equal groups (8 patients per group). Group A will undergo open reduction and internal fixation (ORIF) using a preoperative computed tomography (CT)-based, virtually planned, custom-made modified double T titanium miniplate, whereas Group B will be treated using conventional titanium miniplates placed according to Champy's lines of osteosynthesis. Patients will be followed up clinically and radiographically over a 6-month postoperative period to assess fracture stability, bone healing, functional recovery, and postoperative complications.",[25],"Mandibular Angle Fractures",[25,27],"Inverted T plate","NOT_YET_RECRUITING","2026-11-18",{"date":31,"type":32},"2026-11-25","ACTUAL",{"date":34,"type":19},"2026-12-15",{"date":36,"type":19},"2028-01-15",{"name":38,"class":39},"Suez Canal University","OTHER",1,{"id":42,"slug":43,"hasResults":11,"nctId":44,"briefTitle":45,"officialTitle":45,"acronym":4,"eligibilityCriteria":46,"healthyVolunteers":11,"sex":15,"minAge":16,"maxAge":47,"enrollmentInfo":48,"targetDuration":4,"studyType":20,"phases":49,"briefSummary":50,"conditions":51,"keywords":53,"overallStatus":28,"whyStopped":4,"lastUpdateSubmitDate":57,"lastUpdatePostDateStruct":58,"startDateStruct":60,"completionDateStruct":62,"leadSponsor":64,"locationsCount":4},"100662280","clinical-and-radiographic-assessment-of-h-shaped-bone-plates-in-management-of-body-and-angle-mandibular-fractures-100662280","NCT07902063","Clinical And Radiographic Assessment of H-shaped Bone Plates in Management of Body and Angle Mandibular Fractures","Inclusion Criteria:\n\n* Patients presenting with recent, uninfected, and minimally displaced or unfavorable fractures at the body region of the mandible or the mandibular angle.\n* Adult patients aged between 21 and 60 years old who agree to comply with the 6-month postoperative follow-up schedule (immediate, 1 month, 3 months, and 6 months).\n* Patients with a mandibular fracture requiring open reduction and internal fixation (ORIF).\n* Patients who are medically fit to undergo general anesthesia.\n\nExclusion Criteria:\n\n* Patients presenting with comminuted or clinically infected mandibular fractures.\n* Patients under 21 years of age, or patients over 60 years of age with a completely edentulous mouth.\n* Patients with systemic medical conditions or compromises that interfere with normal bone healing or contraindicate general anesthesia.","60 Years",{"count":18,"type":19},[22],"Clinical and Radiographic Assessment of H-shaped Bone Plates in Management of Body and Angle Mandibular Fractures",[25,52],"Mandibular Body Fractures",[54,55,56],"Mandibular body fracture","Mandibular angle fracture","H shape plate","2026-10-21",{"date":59,"type":32},"2026-10-28",{"date":61,"type":19},"2026-11-15",{"date":63,"type":19},"2027-12-15",{"name":38,"class":39}]