[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-studies-list:{\"conditionNormalized\":\"reduced-left-ventricular-ejection-fraction\",\"overallStatus\":[\"RECRUITING\",\"AVAILABLE\",\"NOT_YET_RECRUITING\"],\"orderBy\":\"LastUpdateSubmitDate:desc\",\"size\":25,\"offset\":0}":3,"health-study-condition:reduced-left-ventricular-ejection-fraction":29},{"pageToken":4,"total":5,"offset":6,"count":5,"results":7},null,1,0,[8],{"id":9,"slug":10,"hasResults":11,"nctId":12,"briefTitle":13,"officialTitle":14,"acronym":15,"eligibilityCriteria":16,"healthyVolunteers":11,"sex":17,"minAge":18,"maxAge":4,"enrollmentInfo":19,"targetDuration":4,"studyType":22,"phases":23,"briefSummary":25,"conditions":26,"keywords":30,"overallStatus":36,"whyStopped":4,"lastUpdateSubmitDate":37,"lastUpdatePostDateStruct":38,"startDateStruct":41,"completionDateStruct":43,"leadSponsor":45,"locationsCount":48},"100662790","lbbap-versus-ilr-in-patients-with-new-onset-lbbb-and-moderately-reduced-lvef-after-tavi-100662790",false,"NCT07909239","LBBAP Versus ILR in Patients With New-Onset LBBB and Moderately Reduced LVEF After TAVI","Comparison of Left Bundle Branch Area Pacing (LBB(AP)) and Implantable Loop Recorder (ILR) in Patients With New-onset Left Bundle Branch Block and Moderately Reduced LVEF After Transcatheter Aortic Valve Implantation (TAVI): A Randomized Multicenter Study.","LBB(AP)TAVI","Inclusion Criteria:\n\n1. Patients with new-onset complete left bundle branch block (LBBB) defined as QRS duration \\>120 ms, occurring after TAVI and persisting for \\>24 hours on ECG. New-onset complete LBBB will be confirmed by QRS duration \\>120 ms together with standard morphological criteria (broad, notched or slurred R waves in leads I, aVL, V5 and V6, with absence of Q waves in V5-V6), assessed by the site cardiologist and confirmed by the adjudication committee, in line with current ESC and ACC\u002FAHA\u002FHRS recommendations.\n2. Left ventricular ejection fraction (LVEF) between 35% and 50%, assessed within one month before TAVI, in a stable hemodynamic state.\n3. Patients implanted with a self-expanding or balloon-expandable valve.\n4. Age ≥ 18 years.\n5. TAVI procedure performed according to current ESC guidelines. The applicable reference is the 2025 ESC\u002FEACTS Guidelines for the management of valvular heart disease (Praz, et al. Eur Heart J. (2025) 46, 4635-4736), or any subsequent official ESC update in force at the time of each patient's procedure.\n6. Life expectancy \\> 1 year.\n7. Affiliation to a social security scheme\n8. Written informed consent provided before study enrollment.\n\nExclusion Criteria:\n\n1. Permanent pacemaker implantation (PPI) before TAVI.\n2. Complete atrioventricular block after TAVI leading to immediate PPI.\n3. Permanent pacemaker implantation after TAVI for another indication (non-protocol).\n4. Pre-existing LBBB before TAVI.\n5. Trans-venous permanent pacemaker implantation: No superior vena cava access or mechanical tricuspid valve.\n6. Pregnancy or breastfeeding.\n7. No affiliation to a social security scheme.\n8. Refusal to participate or withdrawal of informed consent.\n9. Incapacity to consent.\n10. Adults under legal protection (trusteeship, guardianship, curatorship).","ALL","18 Years",{"count":20,"type":21},700,"ESTIMATED","INTERVENTIONAL",[24],"NA","Patients with new-onset complete LBBB (QRS \\> 120 ms, persisting \\> 24 h after TAVI) and moderately reduced LVEF (35-50%) will be screened in participating centers.\n\nEligible patients will be centrally randomized 1:1 (stratified by center and atrial fibrillation (yes\u002Fno)) to either:\n\n* Experimental arm: Left bundle branch area pacing (LBB(AP)) with Biotronik pacemaker and dedicated conduction system pacing leads.\n* Control arm: Implantable loop recorder (ILR, Biotronik BIOMONITOR IV) for rhythm monitoring.\n\nThe occurrence of the following events within 12 months of randomization will be evaluated: hospitalization for heart failure, syncope or hemodynamically significant dizziness, or high-grade atrioventricular conduction disturbance.\n\nThe impact of LBB(AP) compared to ILR monitoring will be evaluated at 6, 12, 24, and 36 months regarding: incidence of atrial fibrillation; incidence of non-sustained ventricular tachycardia; evolution of left ventricular ejection fraction; quality of life; hospitalizations; mortality; medico-economic outcomes; qccurrence of high-grade AV conduction disorders beyond 12 months; omplications related to pacemaker or ILR implantation; unscheduled pacemaker implantation in the ILR group.\n\nPatients will be monitored following a regular schedule that includes clinical visits, transthoracic echocardiography , ECG, remote device monitoring, and EQ-5D at 6, 12, 24 and 36 months.",[27,28,29],"TAVI(Transcatheter Aortic Valve Implantation)","Left Bundle Branch Block","Reduced Left Ventricular Ejection Fraction",[31,32,33,34,35],"TAVI","new onset left bundle branch block","implantable loop recorder","left bundle branch area pacing","moderately reduced LVEF (35-50%)","NOT_YET_RECRUITING","2026-11-13",{"date":39,"type":40},"2026-11-16","ACTUAL",{"date":42,"type":21},"2026-10-15",{"date":44,"type":21},"2034-10-15",{"name":46,"class":47},"University Hospital, Clermont-Ferrand","OTHER",3]