68Ga-CAIX PET Imaging in Different Types of Tumors

ConditionSolid Tumors
Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorShanghai East Hospital

About this trial

This study aims to evaluate the clinical usefulness and safety of a new imaging tracer, gallium-68-labeled carbonic anhydrase IX (68Ga-CAIX), for positron emission tomography (PET) imaging in patients with different types of solid tumors.

Carbonic anhydrase IX (CAIX) is a protein that is often found at increased levels in certain cancers, particularly in tumors with low oxygen levels. Imaging this protein may help doctors identify and evaluate tumor lesions.

This prospective, single-center study plans to enroll approximately 100 adult patients with solid tumors. Each participant will undergo two PET scans: a conventional 18F-FDG PET scan and an investigational 68Ga-CAIX PET scan, generally within 10 days of each other.

Researchers will evaluate how well 68Ga-CAIX PET identifies primary tumors and metastatic lesions, measure tracer uptake in different tumor types, and compare its imaging findings with those of 18F-FDG PET. Available pathology and clinical follow-up information will also be collected to help interpret the imaging results.

The safety of 68Ga-CAIX will be assessed by monitoring adverse events associated with the imaging procedure. This is a diagnostic imaging study and does not involve experimental cancer treatment.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age ≥18 years.

Clinically confirmed diagnosis of a tumor.

Life expectancy of at least 3 months.

Eastern Cooperative Oncology Group (ECOG) performance status ≤2.

Disqualifiers

Pregnancy or breastfeeding.

Severe claustrophobia.

Severe medical condition that prevents the participant from undergoing further diagnostic evaluation or treatment.

Trial design

Design model

Single group

Treatments tested in this trial

  • 68Ga-CAIX

    Drug

    Participants will receive a single intravenous injection of the investigational radiotracer 68Ga-CAIX, targeting carbonic anhydrase IX (CAIX), at a recommended administered activity of 3-6 mCi. PET imaging will be performed approximately 60 ± 10 minutes after injection. Images will be evaluated for visualization and radiotracer uptake in primary and metastatic tumor lesions, including SUVmax, SUVmean, and tumor-to-background ratio (TBR). Safety will be monitored following tracer administration.

  • 18F-Fluorodeoxyglucose

    Drug

    Participants will undergo conventional 18F-FDG PET imaging according to standard clinical procedures, including fasting, blood glucose assessment, intravenous administration of 18F-FDG, and PET image acquisition. Imaging findings will be used as a within-subject comparator to evaluate lesion detection and radiotracer uptake relative to investigational 68Ga-CAIX PET. Both PET examinations are planned to be completed within 10 days, with the examination order determined by clinical scheduling and radiotracer availability.

Treatment groups

100 Participants
are divided into 1 treatment group
Group A: 68Ga-CAIX PET and 18F-FDG PET ImagingExperimental treatment 2 interventions

Trial outcomes

Primary outcomes

1

Number of Tumor Lesions With Positive Uptake on 68Ga-CAIX PET

The number of primary and metastatic tumor lesions showing visually positive uptake on 68Ga-CAIX PET will be recorded. Each evaluated lesion will be classified as PET-positive or PET-negative based on focal, nonphysiological tracer uptake confirmed on multiplanar images. The number of PET-positive lesions will be reported separately for primary and metastatic tumor sites. The unit of measurement is the number of lesions.

Time frame
At 68Ga-CAIX PET imaging (Day 0 to Day 10)
2

Maximum Standardized Uptake Value of Tumor Lesions on 68Ga-CAIX PET

The maximum standardized uptake value (SUVmax) will be measured for each evaluable primary and metastatic tumor lesion on 68Ga-CAIX PET images. SUVmax represents the highest standardized radiotracer uptake within the lesion. Values will be summarized according to tumor type and lesion location. SUVmax is a unitless quantitative parameter.

Time frame
At 68Ga-CAIX PET imaging (Day 0 to Day 10)
3

Mean Standardized Uptake Value of Tumor Lesions on 68Ga-CAIX PET

The mean standardized uptake value (SUVmean) will be measured within the defined region or volume of interest for each evaluable primary and metastatic tumor lesion on 68Ga-CAIX PET images. SUVmean reflects the average standardized radiotracer uptake within the lesion. Values will be summarized according to tumor type and lesion location. SUVmean is unitless.

Time frame
At 68Ga-CAIX PET imaging (Day 0 to Day 10)
4

Tumor-to-Background Uptake Ratio on 68Ga-CAIX PET

The tumor-to-background ratio (TBR) will be calculated for each evaluable primary and metastatic tumor lesion using radiotracer uptake in the lesion relative to uptake in the designated background reference region. TBR values will be summarized according to tumor type and lesion location. TBR is expressed as a unitless ratio.

Time frame
At 68Ga-CAIX PET imaging (Day 0 to Day 10)

Secondary outcomes

1

Difference in Lesion Detection Rates Between 68Ga-CAIX PET and 18F-FDG PET

The lesion detection rates of 68Ga-CAIX PET and 18F-FDG PET will be compared within the same participants. For each tracer, the detection rate will be calculated as the number of reference-standard-confirmed tumor lesions detected on PET divided by the total number of confirmed target lesions, multiplied by 100. The difference between the two detection rates will be expressed in percentage points.

Time frame
Up to 6 months after PET imaging (±2 weeks), including reference-standard assessment
2

Correlation Between 68Ga-CAIX PET SUVmax and CAIX Immunohistochemical Expression

The correlation between 68Ga-CAIX PET SUVmax and CAIX protein expression will be evaluated in tumor lesions with available tissue specimens. CAIX expression will be assessed using immunohistochemical H-score or the percentage of CAIX-positive tumor cells, as available. The association will be quantified using Pearson or Spearman correlation coefficients, as appropriate. Correlation coefficients are unitless.

Time frame
Up to 6 months after PET imaging (±2 weeks), including pathology data collection
3

Number of Participants With Adverse Events Following 68Ga-CAIX Administration

The number of participants experiencing at least one adverse event (AE) following intravenous administration of 68Ga-CAIX will be recorded, regardless of its relationship to the investigational tracer. Adverse events will be assessed and graded according to the Common Terminology Criteria for Adverse Events version 5.0 (CTCAE v5.0). Results will be reported as the number of participants with at least one AE.

Time frame
From 68Ga-CAIX administration through 14 days after injection

Other outcomes

Locations

This trial has no locations.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: