About this trial
Validating the safety and efficacy of pressure monitoring technology and star-shaped marking technology for the treatment of paroxysmal atrial fibrillation
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Patient age between 18 and 80 years old, male or non-pregnant female.
Confirmed diagnosis of paroxysmal atrial fibrillation requiring catheter radiofrequency ablation surgery.
Fully understands the treatment plan and voluntarily signs the informed consent form, willing to undergo the examinations, surgery, and follow-up required by the plan.
Disqualifiers
Post-ablation for atrial fibrillation
Reproductive-age patients who cannot use effective contraception within 12 months of enrolment
Left atrial size ≥50 mm, left ventricular ejection fraction ≤40%
Left atrial thrombus
Trial design
Single group
Treatments tested in this trial
FireMagic™ Magbot Ablation Catheter 、FireMagic™ TrueForce™ Ablation Catheter
Device1. The pressure-sensing catheter primarily consists of electrodes, a catheter body, and a control handle. The catheter body comprises a high-torque body and a flexible tip, divided into an adjustable bending segment and a main segment. By pushing or pulling the handle at the proximal end of the catheter, the internal traction wire at the catheter tip can be activated to control the bending of the tip. The adjustable bending segment is fixed with four electrodes at regular intervals, including one tip electrode and three ring electrodes. 2. The disposable star-shaped magnetoelectric positioning catheter is specifically designed for cardiac electrophysiological mapping. The distal end of the catheter has multiple 3F branches, each with multiple platinum-iridium electrodes for collecting cardiac electrophysiological signals. The distal end of the catheter features an adjustable bend design; pushing the button on the catheter forward will cause the distal end of the catheter to bend.
Treatment groups
Trial outcomes
Primary outcomes
Three-month follow-up success rate after surgery
Postoperative 3-month treatment success rate: Specifically refers to the proportion of participants who, during the 3-month follow-up period (after the washout period), did not experience any episodes of atrial fibrillation/atrial flutter/atrial tachycardia lasting ≥30 seconds, as confirmed by electrocardiogram (ECG), Holter monitoring, or equivalent rhythm monitoring methods (including single-lead ECG), without the use of Class I or Class III antiarrhythmic drugs, relative to the total number of enrolled participants.
Secondary outcomes
Immediate ablation success rate
This refers to the proportion of subjects who achieved electrical isolation after surgery among the total number of patients enrolled in the study. The verification method involves waiting for 20 minutes after successful pulmonary vein electrical isolation and then reconfirming pulmonary vein conduction block.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: