Intelligent Classification of Intraoperative Hemodynamic Phenotypes Based on CADFlow Doppler Monitoring

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorShanghai 6th People's Hospital

About this trial

The goal of this observational study is to learn about intraoperative hemodynamic phenotypes in adult patients undergoing elective surgery under general anesthesia, using a new wearable ultrasound patch (CADFlow) that continuously monitors carotid and jugular blood flow. The main question it aims to answer is:

Can a machine learning model built solely on non-invasive carotid and jugular Doppler data accurately identify and classify a patient's hemodynamic phenotype in real time during surgery? Participants undergoing routine elective surgery who are monitored with the CADFlow device as part of standard care will be recorded continuously from after tracheal intubation until the end of surgery. The collected signals will be used to discover distinct hemodynamic phenotypes and to train a model that classifies each patient's phenotype in real time.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Provides written informed consent to participate in the study;

Age 18 years or older;

Body mass index (BMI) between 18 and 30 kg/m2;

American Society of Anesthesiologists (ASA) physical status class I-III;

Disqualifiers

Severe cardiac arrhythmia (e.g., atrial fibrillation, frequent premature ventricular contractions) that compromises signal accuracy;

Pregnancy;

Anatomical abnormality of the carotid artery or jugular vein, or extremely poor ultrasound signal quality.

Trial population

Adult patients scheduled for elective, supine, general-anaesthesia surgery.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

Not listed

Trial groups

440 Participants
are grouped into 1 trial group
Group A: Adult patients scheduled for elective surgery

Trial outcomes

Primary outcomes

1

Real-time phenotype classification performance of the machine-learning model

Using the phenotype labels derived from unsupervised clustering of intraoperative CADFlow multimodal data, a supervised learning model will be trained to classify the current intraoperative hemodynamic phenotype in real time. Performance will be assessed by accuracy, macro-averaged AUC and macro-averaged F1-score.

Time frame
Intraoperatively, from completion of tracheal intubation to the end of surgery

Secondary outcomes

1

Phenotype feature-profile characterisation

Distribution of CADFlow parameters across the discovered phenotypes (box/ violin plots) to verify physiological interpretability

Time frame
Intraoperative
2

Stability and interpretability of the unsupervised clustering solution

Stability and interpretability of the unsupervised clustering solution (Silhouette coefficient, Calinski-Harabasz index, Bootstrap stability) and the association between phenotypes and intraoperative events such as hypotension and vasopressor use.

Time frame
Intraoperative

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: