About this trial
The objective of the study is to evaluate the safety and effectiveness of the TMChM tendon prosthesis in the treatment of patients with chronic flexor tendon injuries of the fingers, compared with a reference tendon prosthesis currently used in clinical practice.
To achieve this objective, finger flexor tendon function will be assessed before and after implantation of either the TMChM tendon prosthesis or the reference prosthesis in patients with chronic flexor tendon injuries of the fingers.
The study is designed to demonstrate that the investigational TMChM tendon prosthesis is non-inferior in terms of effectiveness and safety to the prosthesis currently used in clinical practice.
The study aims to answer the following questions:
* Does the use of the TMChM finger flexor tendon prosthesis result in non-inferior functional outcomes, as assessed by finger tendon function parameters, in patients with chronic flexor tendon injuries compared with the prosthesis currently used in clinical practice? * Can the TMChM tendon prosthesis be safely implanted using the intended surgical technique? The investigational medical device is the TMChM temporary finger flexor tendon prosthesis. The prosthesis incorporates an attachment for the FDS-FDP loop, enabling functional activation of the prosthesis and maintaining tension in the flexor muscles. Additionally, it allows for shaping of the FDS-FDP connection.
The patented TMChM temporary finger flexor tendon prosthesis features an attachment located at the proximal end of its silicone core. The prosthesis attachment has a semicircular cross-section, while the core has rounded sides and a rounded distal end.
The TMChM prosthesis is intended for implantation during the first stage of surgical treatment of chronic flexor tendon injuries of the fingers.
Furthermore, the TMChM prosthesis contains barium sulfate as a radiopaque marker, allowing it to be visualized during X-ray examinations.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Provision of written informed consent to participate in the clinical investigation.
Male and female patients aged ≥18 years.
Confirmed by X-ray examination.
Confirmed by ultrasound examination.
Disqualifiers
Inadequate condition of the skin and soft tissues at the surgical site that precludes surgical reconstruction.
Poor general health status that prevents the patient from undergoing surgical treatment.
Active infection at the planned surgical site.
Neuromuscular disorders that may pose a high risk of surgical failure or postoperative complications.
Trial design
Parallel
Treatments tested in this trial
Two-Stage Flexor Tendon Reconstruction with Temporary Tendon Prosthesis Implantation
Procedure/SurgeryChronic finger flexor tendon injuries are treated using a two-stage surgical procedure. During the first stage, the temporary tendon prosthesis is implanted to create a tendon sheath tunnel for subsequent grafting. The damaged tendon remnants are removed, and the pulleys and digital nerves are reconstructed if necessary. The prosthesis is secured distally to the FDP stump and proximally to the FDS-FDP tendon loop. Passive rehabilitation begins after wound healing. After approximately 10-12 weeks, the second procedure is performed. The prosthesis is removed and replaced with a tendon graft harvested from the forearm, which is passed through the newly formed tunnel and fixed to the distal phalanx. The procedure concludes with wound closure and immobilization of the wrist and fingers, followed by controlled postoperative rehabilitation.
Treatment groups
Trial outcomes
Primary outcomes
Recovery of finger flexor tendon function
Finger flexor tendon function is assessed with the Buck-Gramcko Scoring System (0-15 points; higher scores indicate better function). A goniometer and ruler are used to evaluate three components: (1) Total active motion (TAM), calculated as the sum of active flexion at the metacarpophalangeal (MCP), proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints minus their extension deficits: \>159°=6, 141-159°=4, 120-140°=2, \<120°=0 points. (2) Fingertip-to-distal-palmar-crease distance during maximal active flexion: \<2.5 cm=6, 2.5-\<4 cm=4, 4-6 cm=2, \>6 cm=0 points. (3) Total active extension deficit across MCP, PIP and DIP joints: 0-30°=3, 31-50°=2, 51-70°=1, \>70°=0 points. Component scores are summed (0-15): excellent=14-15, good=11-13, fair=7-10, poor=0-6. The total score is compared between TMChM and reference-prosthesis groups; the target difference is 1.5 points in favor of TMChM.
Secondary outcomes
Finger Range of Motion
Assessment of the total active flexion of the proximal interphalangeal (PIP) and distal interphalangeal (DIP) joints, corrected for extension deficits, using the Modified Strickland method. The expected improvement is 10 ± 5% following treatment with the TMChM prosthesis and its dedicated surgical technique compared with the reference prosthesis.
Grip and Pinch Strength
Assessment of overall hand grip strength and pinch strength using a Jamar hydraulic dynamometer. The expected improvement is 10 ± 5% in the TMChM group compared with the reference prosthesis group.
Two-Point Discrimination
Assessment of tactile sensitivity using the Dellon two-point discriminator. The expected outcome is a reduction of 3 ± 1 mm in the minimum distance between two distinguishable points in the TMChM group compared with the reference prosthesis group.
Upper Extremity Function
Hand function will be assessed using the Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire, a validated 30-item patient-reported outcome measure evaluating upper limb function, limitations in daily activities, and symptoms, including pain. Each item is rated on a 5-point scale (1-5). Responses are converted into a total DASH score ranging from 0 to 100 points, where 0 indicates no disability and 100 indicates the most severe disability. Higher scores reflect worse upper limb function and greater symptom burden. A decrease in the DASH score indicates clinical improvement. The study aims to demonstrate a 10±5% improvement in hand function and reduction in pain-related symptoms in patients treated with the investigational TMChM prosthesis compared with those treated with the reference prosthesis.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
ChM sp. z o.o.
Lead sponsor
CTC Team Sp. z o.o.
Collaborator
This trial is not recruiting at the moment. You can still explore other options: