A Novel Multimodal Approach to Promote Motor Recovery and Plasticity After Stroke

ConditionStroke
Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age40-85
SponsorUniversity of Utah

About this trial

Upper extremity (UE) paresis or weakness is one of the most frequent impairments after stroke. Despite intense rehabilitation, motor and functional recovery of patients with severe hand impairments is poor. Hence, there is a need for more effective treatments to enhance motor function in patients with severe hand impairments after stroke. Adaptive functional electrical stimulation (FES) appears to be a promising treatment and has the potential to facilitate active movement in individuals with severe impairments post-stroke. In addition, transcranial random noise stimulation (trns) is a widely studied, non-invasive and safe method to enhance the corticomotor excitability in individuals with chronic stroke. However, the effect of combining trns and adaptive FES in patients with severe hand impairments has not been investigated. Therefore, the purpose of this study is to investigate whether combining trns with FES will enhance hand function in individuals with chronic stroke than FES alone. The investigators predict that combining trns with FES will significantly enhance hand function than FES alone.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age between 40-85 years

Diagnosis of first-ever subcortical stroke (single cerebrovascular accident)

Stroke onset of at least six months prior to the time of participation

Limited functional wrist and finger flexion and extension, as indicated between 5º-20º active movement

Disqualifiers

Presence of severe aphasia preventing the ability to follow 1-step directions at least 80% of the time

Excessive spasticity of the wrist and finger muscles, defined as a Modified Ashworth Score >2

Diagnosis of neurological disorders other than stroke

History of recent seizure or epilepsy while taking anticonvulsants

Trial design

Design model

Parallel

Treatments tested in this trial

  • tRNS (Transcranial Random Noise Stimulation)

    Device

    Individuals in this group will receive tRNS at 2 mA intensity between 101-640 Hz. The current will be gradually ramped up for and down for the first and last 30 seconds of the stimulation.

  • FES (Functional Electrical Stimulation)-assisted task-specific practice

    Device

    The FES-assisted task-specific practice will focus on restituting the movement components composing functional tasks. We will use the principles of motor learning with FES-assisted task-specific practice. Based on motor learning principles, our intervention will include 1) movement practice as close to normative as possible, 2) a high number of repetitions, 3) attention to the motor task, and 4) training specificity.

  • Sham-tRNS (Transcranial Random Noise Stimulation)

    Device

    Individuals in this group will receive sham-tRNS via the same electrode configuration as the tRNS. The stimulation will gradually ramp up for 30 seconds and then fade away for the rest of the intervention session.

Treatment groups

78 Participants
are divided into 2 treatment groups
Group A: sham-tRNS and FES-assisted task-specific practiceSham comparator 2 interventions
Group B: tRNS and FES-assisted task-specific practiceExperimental treatment 2 interventions

Trial outcomes

Primary outcomes

1

Upper Extremity Fugl-Meyer Scale

Changes in Upper Extremity Fugl-Meyer between the experimental (tRNS and FES-assisted task-specific practice) and control (sham-tRNS and FES-assisted task-specific practice) conditions. This scale measures voluntary motor control of the paretic upper extremity (UE) using a 3-point ordinal scale where 0=cannot perform, 1=performs partially, and 2=performs fully. The total possible score ranges from 0-66 with higher scores indicating a better voluntary motor control of the paretic UE.

Time frame
6-9 weeks post-intervention
2

Stroke Impact Scale - Hand Function Score

Changes in Stroke Impact Scale - Hand Function Score between the experimental (tRNS and FES-assisted task-specific practice) and control (sham-tRNS and FES-assisted task-specific practice) conditions. Participants report paretic upper extremity (UE) use in five commonly performed daily tasks (e.g., carry a bag of groceries) using a 5-point ordinal scale, which ranges from 0-5, where 0=cannot use paretic and 5=not difficult at all to use paretic UE. The total score ranges from 0-25 with higher scores indicating better UE function.

Time frame
6-9 weeks post-intervention
3

Transcranial Magnetic stimulation-induced motor evoked potential

Changes in cortical motor evoked potentials (MEPs) between the experimental (tRNS and FES-assisted task-specific practice) and control (sham-tRNS and FES-assisted task-specific practice) conditions. MEPs will be obtained by placing a transcranial magnetic stimulation (TMS) coil over the hand knob of the ipsilesional primary motor cortex. TMS-induced MEP amplitude will be obtained by averaging peak to peak amplitudes of 20 MEPs from the flexor carpii radials and/or extensor digitorum communis muscles. Higher values of MEP indicate greater corticospinal excitability.

Time frame
6-9 weeks post-intervention

Secondary outcomes

1

Upper Extremity Fugl-Meyer Scale

Changes in Upper Extremity Fugl-Meyer between the experimental (tRNS and FES-assisted task-specific practice) and control (sham-tRNS and FES-assisted task-specific practice) conditions. This scale measures voluntary motor control of the paretic upper extremity (UE) using a 3-point ordinal scale where 0=cannot perform, 1=performs partially, and 2=performs fully. The total possible score ranges from 0-66 with higher scores indicating a better voluntary motor control of the paretic UE.

Time frame
12-14 weeks post intervention
2

Stroke Impact Scale - Hand Function Score

Changes in Stroke Impact Scale - Hand Function Score between the experimental (tRNS and FES-assisted task-specific practice) and control (sham-tRNS and FES-assisted task-specific practice) conditions. Participants report paretic upper extremity (UE) use in five commonly performed daily tasks (e.g., carry a bag of groceries) using a 5-point ordinal scale, which ranges from 0-5, where 0=cannot use paretic and 5=not difficult at all to use paretic UE. The total score ranges from 0-25 with higher scores indicating better UE function.

Time frame
12-14 weeks post intervention
3

Transcranial Magnetic stimulation-induced motor evoked potential

Changes in cortical motor evoked potentials (MEPs) between the experimental (tRNS and FES-assisted task-specific practice) and control (sham-tRNS and FES-assisted task-specific practice) conditions. MEPs will be obtained by placing a transcranial magnetic stimulation (TMS) coil over the hand knob of the ipsilesional primary motor cortex. TMS-induced MEP amplitude will be obtained by averaging peak to peak amplitudes of 20 MEPs from the flexor carpii radials and/or extensor digitorum communis muscles. Higher values of MEP indicate greater corticospinal excitability.

Time frame
12-14 weeks post intervention

Other outcomes

1

Grip Strength of the paretic hand

Changes in Grip Strength between the experimental (tRNS and FES-assisted task-specific practice) and control (sham-tRNS and FES-assisted task-specific practice) conditions. Average grip strength of the of three trials will be reported in kilograms. Higher values indicate better grip strength.

Time frame
6-9 weeks Post-intervention
2

Grip Strength of the paretic hand

Changes in Grip Strength between the experimental (tRNS and FES-assisted task-specific practice) and control (sham-tRNS and FES-assisted task-specific practice) conditions. Average grip strength of the of three trials will be reported in kilograms. Higher values indicate better grip strength.

Time frame
12 -14 weeks Post-intervention
3

Upper extremity muscle synergy

Changes in upper extremity muscle synergy between the experimental (tRNS and FES-assisted task-specific practice) and control (sham-tRNS and FES-assisted task-specific practice) conditions. Transcranial magnetic stimulation induced motor evoked potentials of different proximal and distal upper extremity muscles are coupled using the synergy weights and activation profiles obtained with a novel Principal component-based motor evoked potential analyses. Higher values suggest better muscle synergy.

Time frame
6-9 weeks Post-intervention
4

Upper extremity muscle synergy

Changes in upper extremity muscle synergy between the experimental (tRNS and FES-assisted task-specific practice) and control (sham-tRNS and FES-assisted task-specific practice) conditions. Transcranial magnetic stimulation induced motor evoked potentials of different proximal and distal upper extremity muscles are coupled using the synergy weights and activation profiles obtained with a novel Principal component-based motor evoked potential analyses. Higher values suggest better muscle synergy.

Time frame
12-14 weeks Post-intervention

Sponsors and contacts

Click on the lead sponsor to view all of their trials.