About this trial
The goal of this prospective, non-randomized trial is to determine the safety and technical success of a novel modification to a U.S. Food and Drug Administration (FDA)-approved hybrid frozen elephant trunk (FET) device (Thoraflex Hybrid, Terumo Aortic). The modification is intended to enable supra-aortic vessel stenting in patients undergoing aortic arch replacement for aortic aneurysm or dissection.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age 18 years or older.
Willing and able to give written informed consent, or the patient's legally authorized representative has given written informed consent.
Expected life expectancy of more than two years after repair.
Aortic pathology requiring repair or replacement of multiple damaged or diseased segments of the thoracic aorta, with at least one of the following: (a) thoracic aortic aneurysm at increased risk for rupture or complications; (b) acute aortic dissection requiring urgent repair; (c) aortic pseudoaneurysm at risk for rupture or complications; (d) penetrating aortic ulcer (PAU) at risk for rupture or complications; (e) congenital aortic disease requiring repair.
Disqualifiers
Unfit for open surgical repair involving circulatory arrest.
Comatose or suffering from irreversible severe brain malperfusion.
Known sensitivity to components of the devices.
Active systemic infection that, in the opinion of the investigator, would compromise the outcome of the surgical procedure.
Trial design
Single group
Treatments tested in this trial
Modified Supra-Aortic Frozen Elephant Trunk (SA-FET) Device
DeviceThe proposed SA-FET procedure consists of a hybrid frozen elephant trunk (FET) device (Thoraflex, Terumo) with up to three reinforced fenestrations on the proximal endograft segment. Each fenestration is sized from 4 to 13 millimeters (mm) based on the size of the targeted supra-aortic vessel and wire-reinforced circumferentially using continuous watertight anastomosis-type suturing with polyester suture, as is done in commercially available fenestrated aortic endografts. The reinforcement provides an anchoring point against the radial force of the branch stents to maintain a seal and prevent tearing of the aortic endograft, and also provides a radiopaque marker. The fenestration is then pre-wired to allow delivery of a branch stent graft (Gore Viabahn). After deployment of the fenestrated graft, the supra-aortic branch stent grafts are deployed. The branch stent may be additionally secured to the fenestration using interrupted or continuous suturing with polypropylene suture.
Treatment groups
Trial outcomes
Primary outcomes
All-cause mortality
Rate of death from any cause
Stroke, excluding transient ischemic attack (TIA)
Rate of stroke
Early Paralysis, excluding paraparesis
Rate of paralysis
Technical success
Composite of successful delivery of the device through the vasculature, successful deployment of the device at the intended location, and patient survival
Secondary outcomes
Aortic-related death
Rate of aortic-related death
Pseudoaneurysm at the treatment sites
Rate of pseudoaneurysm at the treatment sites
Unanticipated aortic or branch-related reoperation
Rate of unanticipated aortic or branch-related reoperation
Late endoleak
Rate of Type I or III endoleak confirmed by computed tomography (CT) imaging assessment
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: