A Novel Wire-Reinforced Fenestration of a Hybrid Frozen Elephant Trunk Device for Supra-Aortic Branch Vessel Stenting During Aortic Arch Replacement

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorUniversity of Maryland, Baltimore

About this trial

The goal of this prospective, non-randomized trial is to determine the safety and technical success of a novel modification to a U.S. Food and Drug Administration (FDA)-approved hybrid frozen elephant trunk (FET) device (Thoraflex Hybrid, Terumo Aortic). The modification is intended to enable supra-aortic vessel stenting in patients undergoing aortic arch replacement for aortic aneurysm or dissection.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age 18 years or older.

Willing and able to give written informed consent, or the patient's legally authorized representative has given written informed consent.

Expected life expectancy of more than two years after repair.

Aortic pathology requiring repair or replacement of multiple damaged or diseased segments of the thoracic aorta, with at least one of the following: (a) thoracic aortic aneurysm at increased risk for rupture or complications; (b) acute aortic dissection requiring urgent repair; (c) aortic pseudoaneurysm at risk for rupture or complications; (d) penetrating aortic ulcer (PAU) at risk for rupture or complications; (e) congenital aortic disease requiring repair.

Disqualifiers

Unfit for open surgical repair involving circulatory arrest.

Comatose or suffering from irreversible severe brain malperfusion.

Known sensitivity to components of the devices.

Active systemic infection that, in the opinion of the investigator, would compromise the outcome of the surgical procedure.

Trial design

Design model

Single group

Treatments tested in this trial

  • Modified Supra-Aortic Frozen Elephant Trunk (SA-FET) Device

    Device

    The proposed SA-FET procedure consists of a hybrid frozen elephant trunk (FET) device (Thoraflex, Terumo) with up to three reinforced fenestrations on the proximal endograft segment. Each fenestration is sized from 4 to 13 millimeters (mm) based on the size of the targeted supra-aortic vessel and wire-reinforced circumferentially using continuous watertight anastomosis-type suturing with polyester suture, as is done in commercially available fenestrated aortic endografts. The reinforcement provides an anchoring point against the radial force of the branch stents to maintain a seal and prevent tearing of the aortic endograft, and also provides a radiopaque marker. The fenestration is then pre-wired to allow delivery of a branch stent graft (Gore Viabahn). After deployment of the fenestrated graft, the supra-aortic branch stent grafts are deployed. The branch stent may be additionally secured to the fenestration using interrupted or continuous suturing with polypropylene suture.

Treatment groups

100 Participants
are divided into 1 treatment group
Group A: Supra-aortic frozen elephant trunk (SA-FET)Experimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

All-cause mortality

Rate of death from any cause

Time frame
30 days
2

Stroke, excluding transient ischemic attack (TIA)

Rate of stroke

Time frame
30 days
3

Early Paralysis, excluding paraparesis

Rate of paralysis

Time frame
30 days
4

Technical success

Composite of successful delivery of the device through the vasculature, successful deployment of the device at the intended location, and patient survival

Time frame
24 hours

Secondary outcomes

1

Aortic-related death

Rate of aortic-related death

Time frame
Up to 36 months after the index procedure
2

Pseudoaneurysm at the treatment sites

Rate of pseudoaneurysm at the treatment sites

Time frame
Up to 36 months after the index procedure
3

Unanticipated aortic or branch-related reoperation

Rate of unanticipated aortic or branch-related reoperation

Time frame
Up to 36 months after the index procedure
4

Late endoleak

Rate of Type I or III endoleak confirmed by computed tomography (CT) imaging assessment

Time frame
Up to 36 months after the index procedure

Other outcomes