A Post Market Surveillance Study of the Hemovent Extracorporeal Cardiopulmonary Support System:The MOBYBOX Trial

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18-80
SponsorHemovent GmbH

About this trial

The purpose of this study is to evaluate prospectively the safety and performance of the MOBYBOX System in the veno-arterial configuration in patients with cardiorespiratory failure or in the veno-venous configuration in patients with severe respiratory failure.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

A Murray score ≥ 3.0 and/or severe hypoxemia with A PaO2/FIO2 > 100 mm on 0.9 FIO2;

Uncompensated hypercapnia with pH <7.2 despite a Pplateau > 30 cm H20;

Significant air leak/bronchopleural fistula;

Need for intubation in a patient on lung transplant list;

Disqualifiers

High pressure ventilation (FIO2 > 0.9 and Pplateau > 30 cm H2O) or high FIO2 requirements for more than 7 days;

Severe intracranial bleeding, which precludes the use of anticoagulation therapy or any other inability to be anticoagulated

Excessive weight (> 180 Kg)

Severe irreversible brain injury (e.g., hypoxic brain injury)

Trial population

Consented patients with cardiorespiratory failure or ith severe respiratory failure who meet all of the inclusion and none of the exclusion criteria and in whom the investigator intends to treat the patient with cardiopulmonary support using the Hemovent MOBYBOX System.

Trial design

Design model

Case-only

Time perspective

Prospective

Treatments tested in this trial

  • MOBYBOX System

    Device

    extracorporeal cardiopulmonary support

Treatment groups

No treatment groups listed

Trial outcomes

Primary outcomes

1

Rates of device and procedure related serious adverse events

Acute safety defined as rates of device and procedure related serious adverse events up to 24 hours post-intervention.

Time frame
24 hours

Secondary outcomes

1

Device performance success

Device performance success (defined as the ability to establish either veno-arterial ECMO to support cardiorespiratory function and tissue oxygenation or veno-venous ECMO to support respiratory function and tissue oxygenation)

Time frame
every 4 hours while the patient receives ECMO using the MOBYBOX device
2

Adverse Event rate

Acute safety defined as rates adverse events up to 24 hours post-intervention.

Time frame
24 hours
3

Mortality rate

All-cause mortality up to 30 days post-intervention

Time frame
30 days

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Hemovent GmbH

Lead sponsor

seleon GmbH

Collaborator