About this trial
A laryngeal mask airway is a medical device placed through the mouth to help patients breathe during general anaesthesia. It is commonly used during surgery. Usually, anaesthetists insert this device without directly seeing the opening of the airway. They check its position using breathing measurements, chest movements, and signs of air leakage. However, a device may appear to work normally even when it is not positioned correctly. Changes in head and neck position during surgery may also affect its placement.
The SaCo Video Laryngeal Mask Airway (SaCoVLM) is a newer airway device with a built-in camera that allows anaesthetists to see the opening of the airway and adjust the device's position.
The main aim of this study is to find out whether using the built-in camera to guide and adjust the SaCoVLM during insertion results in better airway positioning than the conventional method, which does not use the camera view. The researchers will also investigate whether the airway device remains correctly positioned when the patient's head and neck are moved.
This study will involve 70 adults aged 18 to 65 years who are scheduled for planned surgery under general anaesthesia at Universiti Malaya Medical Centre, Malaysia.
Participants will be randomly assigned to one of two groups, with an equal chance of being placed in either group:
* Group 1 (Video-guided insertion): The anaesthetist will use the SaCoVLM's built-in camera to guide insertion and adjust the device to achieve a better view of the airway opening. * Group 2 (Conventional blind insertion): The anaesthetist will insert the same device using standard techniques and breathing tests without viewing the camera screen.
After successful insertion, researchers will assess the airway device in four head and neck positions: neutral, turned to the side, tilted backwards, and bent forwards.
The researchers will compare how often the airway opening is partly obscured in each group. They will also measure air leakage around the device, the time and number of attempts needed for insertion, changes in heart rate and blood pressure, and throat-related symptoms after surgery.
All procedures will be performed by experienced anaesthetists under standard monitoring during general anaesthesia. Participants will be assessed for throat-related complications approximately one hour after surgery.
The findings may help determine whether video-guided insertion provides better airway positioning than conventional insertion, particularly during head and neck movement. This information could help improve airway management and patient safety during future surgical procedures.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Adults aged 18-65 years.
American Society of Anesthesiologists (ASA) physical status I or II.
Scheduled for elective non-airway surgery under general anesthesia, with an anticipated surgical duration of 30-180 minutes.
Suitable for airway management using a supraglottic airway device (SAD).
Disqualifiers
Known or anticipated difficult airway, including Mallampati class III-IV, interincisor distance less than 2.5 cm, or reduced neck mobility.
Increased risk of pulmonary aspiration, including inadequate fasting, symptomatic gastroesophageal reflux disease, hiatal hernia, full stomach, or emergency surgery.
Known pharyngeal, laryngeal, or upper airway pathology or mass.
Cervical spine instability, injury, or previous surgery that prevents safe neck rotation, extension, or flexion.
Trial design
Parallel
Treatments tested in this trial
Video-adjusted SaCoVLM insertion
DeviceThe SaCo Video Laryngeal Mask Airway (SaCoVLM) will be inserted under general anaesthesia using its built-in camera for real-time visual guidance. The anaesthetist will observe the glottic opening and perform gentle adjustments in device depth, rotation, or position to achieve an optimal glottic view (Grade 3 or 4) before securing the device. Successful placement will be confirmed using standard clinical airway performance tests, including capnography, bilateral chest movement, absence of audible air leakage, and oropharyngeal leak pressure (OLP). The device will subsequently be assessed in four standardised head and neck positions: neutral supine, 45° lateral rotation, 45° extension, and 30° flexion.
Conventional blind SaCoVLM insertion
DeviceThe SaCo Video Laryngeal Mask Airway (SaCoVLM) will be inserted under general anaesthesia using the conventional blind insertion technique without real-time visual guidance. The device's built-in video monitor will be physically covered from the inserting anaesthetist. Placement will be confirmed using standard clinical airway performance tests, including capnography, bilateral chest movement, absence of audible air leakage, and oropharyngeal leak pressure (OLP). No adjustments will be made based on the video image. The device will subsequently be assessed in four standardised head and neck positions: neutral supine, 45° lateral rotation, 45° extension, and 30° flexion. Video recordings will be collected for independent assessment without revealing the images to the inserting anaesthetist.
Treatment groups
Trial outcomes
Primary outcomes
Incidence of Distorted Glottic View Following Head and Neck Repositioning
The proportion of participants with a distorted glottic view (SaCoVLM Grade 1 or 2) following head and neck repositioning, despite satisfactory conventional airway placement tests. Glottic views will be assessed using recorded SaCoVLM images in three repositioned states: 45° lateral rotation, 45° neck extension, and 30° neck flexion, with neutral supine position as the reference. The incidence will be compared between video-adjusted and conventional blind insertion groups. Grades 1-2 indicate partial visualisation of the laryngeal inlet, whereas Grades 3-4 indicate satisfactory glottic visualisation.
Secondary outcomes
Oropharyngeal Leak Pressure Across Head and Neck Positions
Oropharyngeal leak pressure (OLP), measured in cmH2O, will be assessed in four standardised head and neck positions: neutral supine, 45° lateral rotation, 45° neck extension, and 30° neck flexion. OLP will be measured using the adjustable pressure-limiting valve technique. Measurements will be compared between the video-adjusted and conventional blind insertion groups to evaluate airway seal performance during repositioning.
Time Required for SaCoVLM Insertion
Time in seconds required to achieve confirmed SaCoVLM placement. Confirmation is defined as achieving an optimal glottic view in the video-adjusted group or meeting conventional airway placement criteria in the blind insertion group. Insertion times will be compared between groups to evaluate procedural efficiency.
Number of SaCoVLM Insertion Attempts
Number of attempts required to achieve successful SaCoVLM placement, recorded for each participant. The number of insertion attempts will be compared between the video-adjusted and conventional blind insertion groups to assess insertion efficiency.
Anaesthetist-Rated Ease of SaCoVLM Insertion
Ease of SaCoVLM insertion will be assessed by the inserting anaesthetist using a numerical rating scale (NRS). Ratings will be compared between the video-adjusted and conventional blind insertion groups to evaluate perceived procedural difficulty.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: