A Real-world Evaluation of Insulin Infusion Set Failures

ConditionDiabetes
Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorDCB Research AG

About this trial

The REA study is a prospective, decentralized observational study investigating insulin infusion set failures in adults with type 1 diabetes using the myLoop system. During the three-month study period, participants will collect up to three failed infusion sets and corresponding control sets, while providing CGM and insulin pump data. The study aims to identify factors associated with infusion set failures under real-world conditions.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Diagnosis of T1D for ≥6 months

Current use of myLoop AID system with the YpsoPump since ≥3 months and myOrbit infusion sets

Age ≥18 years

Historical IIS failure rate >5/year (self-reported)

Disqualifiers

Use of SGLT2 inhibitors, GLP-1 agonists or other non-insulin glucose lowering agents

Diabetic ketoacidosis (DKA) or severe hypoglycaemia (SH <54 mg/dL with severe complications or loss of consciousness) in the past 3 months

Known/suspected lipohypertrophy, lipoatrophy, or inflammatory skin condition at infusion sites (> 50% sites affected)

Active skin infections, autoimmune skin disorders, or immunosuppression (e.g. oral steroids)

Trial population

The study plans to recruit approximately 50 adults living with T1D using the myLoop AID system, the YpsoPump and myOrbit infusion sets for their diabetes management.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

Not listed

Trial groups

No trial groups listed

Trial outcomes

Primary outcomes

1

Difference in Cannula Proteomic Profiles Between Failed and Non-Failed Infusion Sets

Proteomic profiles of cannulas from failed and non-failed insulin infusion sets will be compared within the same participant, using non-failed infusion sets as the reference, to identify differences in protein composition.

Time frame
3 months

Secondary outcomes

1

Glucose and Insulin Pump Patterns Associated with Infusion Set Failures

Glucose metrics and insulin pump outcomes associated with reported and confirmed infusion set failures will be assessed over predefined time windows and compared with corresponding periods without failures within the same participant.

Time frame
3 months
2

Frequency and Types of Insulin Infusion Set Failures

The number and types of user-reported and confirmed infusion set failures will be assessed over the study period, including reasons for infusion set replacement, and expressed as occurrences per month.

Time frame
3 months

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

DCB Research AG

Lead sponsor

mylife Diabetes Care AG

Collaborator