About this trial
This clinical trial studies a new screening program to improve the early detection of sporadic pancreatic cancer in individuals with a high risk of developing pancreatic cancer. Pancreatic cancer remains one of the deadliest solid tumors, characterized by a long phase without symptoms followed by rapid progression once clinically evident. Despite advancements in treatment, the survival rate for pancreatic cancer remains low. Research has helped to identify a subset of individuals with a markedly high short-term risk for developing pancreatic cancer, which includes adults aged 50 and older with glycemically-defined new-onset diabetes and an Enriching New-Onset Diabetes for Pancreatic Cancer (ENDPAC) score ≥ 3. However, current practice guidelines do not provide clear pathways for surveillance or early detection. The screening program in this trial combines repeated contrast-enhanced computed tomography (CT) scans using artificial intelligence (AI) and blood draws. Contrast-enhanced CT is an imaging technique which creates a series of detailed pictures of areas inside the body; the pictures are created by a computer linked to an x-ray machine and a contrast agent is used to enhance the images. The images are then reviewed using AI, which may make it easier to spot cancer earlier on the CT scans than with the human eye. Studying samples of blood in the laboratory from high-risk individuals may help doctors understand more about why they may develop pancreatic cancer. This may be an effective way to screen high-risk individuals and improve the early detection of sporadic pancreatic cancer.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age ≥ 50 and ≤ 85 years
Glycemically-defined new-onset diabetes (gNOD) with onset ≤ 180 days preceding enrollment
Enriching New-onset Diabetes for Pancreatic Cancer (ENDPAC) score ≥ 3, based on validated risk stratification models
Provide written or remote informed consent
Disqualifiers
Prior diagnosis of pancreatic ductal adenocarcinoma (PDA)
Known hereditary cancer syndromes (e.g., BRCA1/2, Lynch syndrome, Peutz-Jeghers)
Prior history of pancreatic surgery
Pancreatic cyst surveillance at time of registration
Trial design
Parallel
Treatments tested in this trial
Biospecimen Collection
Procedure/SurgeryUndergo blood sample collection
Computed Tomography with Contrast
Procedure/SurgeryUndergo contrast-enhanced abdominal CT
Electronic Health Record Review
Other interventionUndergo electronic medical record (EMR) surveillance
Treatment groups
Trial outcomes
Primary outcomes
Recruitment yield (Feasibility)
Will assess the feasibility of protocol implementation as defined by recruitment yield (% of flagged high-risk individuals who consent). Descriptive statistics will be used to summarize feasibility endpoints.
Imaging adherence rates (Feasibility)
Will assess the feasibility of protocol implementation as defined by imaging adherence rates (% completing 3 scheduled computed tomography scans). Descriptive statistics will be used to summarize feasibility endpoints.
Blood collection success rates (Feasibility)
Will assess the feasibility of protocol implementation as defined by blood collection success rates (% completing 3 scheduled blood collections). Descriptive statistics will be used to summarize feasibility endpoints.
Completeness of electronic medical record (EMR)-based follow-up (Feasibility)
Will assess the feasibility of protocol implementation as defined by completeness of EMR-based follow-up (% of participants with outcome ascertainment). Descriptive statistics will be used to summarize feasibility endpoints.
Secondary outcomes
Time from glycemically-defined new-onset diabetes (gNOD) onset to pancreatic ductal adenocarcinoma (PDA) diagnosis
Time to PDA diagnosis will be compared between cohorts.
Proportion of PDAs diagnosed at stage 0/I
Comparisons between cohorts will employ log-rank tests. Will also employ Cox proportional hazards models adjusted for baseline covariates (exploratory only).
Rate and type of incidental findings requiring downstream evaluation
Comparisons between cohorts will employ log-rank tests. Will also employ Cox proportional hazards models adjusted for baseline covariates (exploratory only).
Artificial intelligence (AI)-detected imaging signatures and standard radiologist interpretations
Will complete discordance analysis between AI-detected imaging signatures and standard radiologist interpretations, including rates of earlier detection and false positives.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.