About this trial
The goal of this clinical trial is to find out if a new digital surgical guide helps dentists perform esthetic crown lengthening more accurately than the current digital guide in adults with a gummy smile caused by altered passive eruption. Esthetic crown lengthening is a procedure that reshapes the gums and the bone around the teeth to show more of the natural tooth. The main questions this study aims to answer are:
Does the new digital guide help dentists reshape the bone and gums more accurately? Does the new digital guide improve healing, the appearance of the gums, the time needed for surgery, and participants' satisfaction with the results?
Researchers will compare a new stackable digital guide with the current digital guide to see if the new design provides more accurate and predictable results.
Participants will:
* Be randomly assigned to have surgery using either the new digital guide or the current digital guide. * Have dental examinations, digital mouth scans, and three-dimensional dental X-rays before surgery to plan their treatment. * Have esthetic crown lengthening surgery using the assigned guide. * Return for follow-up visits right after surgery and again about 6 weeks and 6 months later so researchers can check healing and compare the planned treatment with the final result. * Answer questions about their satisfaction with the treatment and any pain medicine they used after surgery.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Patients both genders aged from 21-40 years
Patients complaining of Excessive gingival display (3mm or more gingival display at full smiling).
Patients with Altered passive eruption (APE) type 1 B Coslet GJ et al., 1977).
Patients have thick gingival phenotype (thickness of gingiva is ≥ 1 mm) (Greenberg J et al., 1976).
Disqualifiers
Pregnant and lactating females.
Poor oral hygiene.
Smokers.
Patients with systemic diseases which could influence the outcome of the therapy e.g. (Diabetic patients, bleeding disorders).
Trial design
Parallel
Treatments tested in this trial
Stackable double digital periodontal guide
DeviceA custom-made, 3D-printed digital surgical guide used during esthetic crown lengthening. The guide consists of two detachable components: a gingivectomy guide for soft tissue incision and an ostectomy guide that is joined after flap reflection and positioned directly on the alveolar bone to guide bone reduction. The guide is designed using merged cone-beam computed tomography (CBCT) and intraoral scan data to improve the accuracy of bone reshaping.
Conventional double digital periodontal guide
DeviceA custom-made, one-piece 3D-printed digital surgical guide used during esthetic crown lengthening. The guide directs both the gingivectomy and ostectomy based on the planned treatment using intraoral scan data . After flap reflection, the guide is repositioned to guide bone reduction from the soft tissue level.
Treatment groups
Trial outcomes
Primary outcomes
Difference in accuracy of both guides
Evaluation of the degree of matching of the post operative actual gingival zenith points with the virtual predicted presurgical plan. Intraoral digital scanning for both groups will be obtained preoperative, immediately after surgery, and follow up appointments at 6 weeks and 6 months after surgery and exported in STL file format then it will be superimposed on the digitally designed diagnostic STL file to obtain statistical differences.The accuracy can be measured by comparing the planned surgery and the actual result of the surgery Linear measurement in millimeters.
Secondary outcomes
Bone level accuracy
The accuracy can be measured by comparing the planned surgical ostectomy level on the CBCT (cone beam computed tomography) and the actual result of the surgery by Linear measurement in millimeters.
Gingival margin stability
The position of gingival margin in relation to a reference point will be evaluated with linear measurements in millimeters.
Pink Esthetic Score
The \*\*Pink Esthetic Score evaluates seven variables of soft-tissue esthetics. 1)Mesial and distal papillae are scored as missing (0), incomplete (1), or complete (2). 2)Tissue contour is rated as unnatural (0), virtually natural (1), or natural (2). 3)Gingival level is scored according to the discrepancy from the reference tooth: \>2 mm (0), 1-2 mm (1), or \<1 mm (2). 4)Alveolar process, color, and texture are each scored (0),(1) and (2), depending on whether there is a (0)clear difference, (1)slight difference, or (2)no difference. Higher scores indicate better esthetic outcomes with a maximum total score of 14.
Surgical time
The time needed to complete each procedure will be calculated in minutes by using a stopwatch from the time of the first incision till removal of the guide.
Locations
Sponsors and contacts
Click on the lead sponsor to view all of their trials.