Adjustable Carbon Fiber Sternal Plates for Sternotomy Closure

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorNEOS Surgery

About this trial

The goal of this clinical trial is to learn if a new medical device (SC03 plates) to close the sternum after a sternotomy in patients that have been operated of a cardiac surgery, is safe and effective. The main question it aims to answer is:

Do patients that have the sternum closed with the SC03 plates present a stable sternum one month after surgery?

Researchers will compare the SC03 plates with stainless steel wires (current standard of care to close the sternum).

Participants will:

* be implanted with the SC03 or stainless steel wires. * visit the clinic one month and six months after surgery * Keep a diary of their symptoms and analgesia use

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patient ≥ 18 years old.

Patient who must undergo surgery in which a median or an upper partial sternotomy is indicated.

Patients capable of giving their voluntary informed consent to participate in the clinical investigation and from whom written consent has been obtained.

Patient able and willing to meet the protocol requirements and to follow postoperative care instructions

Disqualifiers

Patient with sternal anomalies, such as bone tumours located in the sternum.

Patient with limited sternum bone blood supply.

Patient with suspected or known allergies or intolerances to the implants materials: PEEK, carbon fibre, titanium, stainless steel.

Patient with severe osteoporosis or other degenerative bone diseases that affect the sternum.

Trial design

Design model

Sequential

Treatments tested in this trial

  • SC03 Plating system

    Device

    Adjustable carbon fiber sternal plates

  • Stainless steel wires

    Device

    Nonabsorbable, sterile, surgical sutures used in sternal closure

Treatment groups

190 Participants
are divided into 2 treatment groups
Group A: SC03 platesExperimental treatment 1 intervention
Group B: WiresActive comparator 1 intervention

Trial outcomes

Primary outcomes

1

Sternal stability

Sternal stability measured by clinical assessment using the sternal instability scale (SIS), with grades 0 to 3 where 0 is "Clinically stable sternum" and 3 is "Completely separated sternum - entire length"

Time frame
1 month post operatively

Secondary outcomes

1

Safety of the SC03 Plating System

Incidence of Device Deficiencies, AE and SAE with a possible, probable or causal relationship with the device or the procedure.

Time frame
Perioperative, 1 month and 6 months postoperatively.
2

Reinterventions

Incidence and cause of surgical reinterventions

Time frame
1 month and 6 months postoperatively
3

Infections

Incidence of sternal superficial and deep wound infections (mediastinitis)

Time frame
First month and six months postoperatively.
4

Sternal dehiscence

Incidence of sternal dehiscence (without infection)

Time frame
First month and six months postoperatively

Other outcomes

Locations

This trial has no locations.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

NEOS Surgery

Lead sponsor

Fundacio Privada Mon Clinic Barcelona

Collaborator

This trial is not recruiting at the moment. You can still explore other options: