About this trial
Pancreatic mucinous cystic neoplasms (MCNs), serous cystic neoplasms (SCNs), and pancreatic pseudocysts (PPCs) often exhibit overlapping imaging features on endoscopic ultrasound (EUS). However, these conditions require different clinical management strategies. Accurate differentiation is therefore important for appropriate treatment planning.
This study aims to develop and validate an artificial intelligence (AI) model that integrates EUS images and clinical features to differentiate MCNs, SCNs, and PPCs. The study is designed as an ambispective observational diagnostic study consisting of retrospective model development, prospective temporal validation, and a reader study involving EUS physicians.
Approximately 400 adult patients with confirmed MCN, SCN, or PPC will be included. Retrospective clinical data and EUS images will be used for model development and internal validation. After model development is completed, newly diagnosed patients will be prospectively enrolled to independently evaluate the diagnostic performance of the model.
The primary outcome is the patient-level macro-averaged area under the receiver operating characteristic curve (macro-AUROC) for three-class classification in the prospective validation cohort. Secondary outcomes include diagnostic accuracy, sensitivity, specificity, calibration, clinical net benefit, and the performance of EUS physicians with and without AI assistance.
This study is expected to provide evidence for the potential clinical value of AI-assisted differentiation of pancreatic cystic lesions. No additional invasive procedures or study-specific treatments will be performed.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
**Inclusion Criteria:**
Adults aged 18 years or older, regardless of sex.
Patients who have undergone endoscopic ultrasound (EUS) examination.
A final diagnosis of pancreatic mucinous cystic neoplasm (MCN), serous cystic neoplasm (SCN), or pancreatic pseudocyst (PPC).
Disqualifiers
Severely degraded EUS image quality preventing reliable identification of the target lesion.
Availability of only post-treatment or postoperative EUS images, without pretreatment imaging.
Lack of reliable pathological confirmation for MCN or SCN.
Inability to establish a clear correspondence between the EUS images and the pathologically confirmed lesion.
Trial population
The study population will consist of approximately 400 adult patients aged 18 years or older with a final diagnosis of pancreatic mucinous cystic neoplasm (MCN), serous cystic neoplasm (SCN), or pancreatic pseudocyst (PPC) who have undergone endoscopic ultrasound (EUS) at Ruijin Hospital, Shanghai Jiao Tong University School of Medicine. Approximately 310 retrospective patients will be identified from existing clinical records for AI model development and internal validation. An additional 80-100 eligible patients will be consecutively enrolled for prospective temporal validation after model finalization. MCN and SCN diagnoses will be confirmed by pathology, whereas PPC diagnoses will be established using a predefined composite reference standard. Each patient will contribute one independent study sample regardless of the number of available EUS images.
Trial design
Cohort
Other
Treatments tested in this trial
Not listed
Trial groups
Trial outcomes
Primary outcomes
Patient-Level Macro-AUROC of the Multimodal AI Model for Three-Class Classification of MCN, SCN, and PPC
The diagnostic performance of the locked multimodal artificial intelligence (AI) model will be evaluated in an independent prospective temporal validation cohort using the patient-level macro-averaged area under the receiver operating characteristic curve (macro-AUROC). One-vs-rest AUROC will be calculated separately for mucinous cystic neoplasms (MCNs), serous cystic neoplasms (SCNs), and pancreatic pseudocysts (PPCs). The three AUROC values will then be averaged with equal weighting. Each patient will contribute one final prediction, and 95% confidence intervals will be estimated using bootstrap resampling. Higher values indicate better discrimination.
Secondary outcomes
Overall Patient-Level Classification Accuracy of the AI Model
Overall accuracy will be calculated as the proportion of patients correctly classified as MCN, SCN, or PPC among all patients evaluated in the prospective validation cohort. Accuracy will be reported as a percentage with a 95% confidence interval.
Macro-Averaged F1 Score of the AI Model
The F1 score will be calculated separately for MCN, SCN, and PPC using the harmonic mean of precision and recall. The macro-F1 score will be calculated as the unweighted average of the three class-specific F1 scores. Values range from 0 to 1, with higher values indicating better classification performance.
Difference in Patient-Level Macro-AUROC Between Multimodal and Unimodal AI Models
The difference in patient-level macro-AUROC between the locked multimodal AI model and each unimodal model (EUS image-only and clinical feature-only) will be calculated in the independent prospective validation cohort. Each comparison will be reported as the arithmetic difference in macro-AUROC, with positive values indicating better discrimination by the multimodal model.
Calibration Intercept of the Multimodal AI Model
The calibration intercept of the locked multimodal AI model will be estimated in the prospective validation cohort to assess systematic overestimation or underestimation of predicted probabilities. A value closer to 0 indicates better calibration.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: