About this trial
The goal of this clinical trial is to evaluate the feasibility of a prototype artificial intelligence (AI)-based controller for a lightweight hip exoskeleton across a broad range of users, including healthy younger adults (18-39 years) and older adults (65 years and older). The main questions it aims to answer are:
* Can the AI-based controller accurately estimate gait phase in real time across younger and older adults? * How does hip exoskeleton assistance change walking energy cost, mechanics, and muscle activity?
Researchers will compare walking with powered hip exoskeleton assistance to walking without the exoskeleton and walking while wearing the exoskeleton with no assistance (zero torque).
Participants will:
* Complete a short screening and frailty assessment * Walk on a treadmill under different conditions with and without the hip exoskeleton during 2 to 5 lab visits * Wear motion capture markers, muscle activity (EMG) sensors, and a mask that measures breathing to estimate energy use
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Age 18 to 39 years (younger adult group) or 65 years and older (older adult group)
Willing and able to provide informed consent
Able to walk independently without assistance
No known cardiovascular, metabolic, or renal disease, and no signs or symptoms suggestive of such disease
Disqualifiers
Age 40 to 64 years
Leg surgery within the past 5 years
Orthopedic disability that could impair movement or limit participation in the exercise protocol
Neurologic disorder that may affect neuromuscular function or gait (e.g., stroke, Parkinson's disease, peripheral neuropathy, traumatic brain injury)
Trial design
Single group
Treatments tested in this trial
AI-Driven Hip Exoskeleton Assistance
DeviceA lightweight (3.5 kg) research hip exoskeleton developed at Carnegie Mellon University with powered hip flexion/extension joints, a backpack-mounted computer and battery, and thigh and waist interfaces secured with straps. An AI-driven controller estimates the user's gait state from joint angle and wearable sensor data and commands assistive hip torque in real time, limited to \<0.2 Nm/kg (peak device torque 18 Nm). Participants walk on a treadmill with powered assistance, with the device worn at zero torque, and without the device. The device was determined by the UT Austin IRB to be a non-significant risk device.
Treatment groups
Trial outcomes
Primary outcomes
Gait Phase Estimation Error of the AI-Driven Hip Exoskeleton Controller
Root-mean-square error (RMSE) between the controller's real-time gait phase estimate and ground-truth gait phase derived from force-instrumented treadmill data during powered hip exoskeleton walking, reported as percent of the gait cycle (%). Used to evaluate feasibility of the prototype controller across younger and older adult users.
Secondary outcomes
Net Metabolic Power During Powered Hip Exoskeleton Walking
Net metabolic power (W/kg), measured by open-circuit indirect calorimetry with resting value subtracted, during treadmill walking at 1.25 m/s with powered hip exoskeleton assistance.
Peak Hip Joint Moment During Powered Hip Exoskeleton Walking
Peak biological hip extension moment (Nm/kg), computed from motion capture and force-instrumented treadmill data, during treadmill walking with powered hip exoskeleton assistance.
Lower-Limb Muscle Activity During Powered Hip Exoskeleton Walking
Average electromyography (EMG) amplitude normalized to maximum voluntary contraction (%MVC), averaged across eight recorded lower-limb muscles, during treadmill walking with powered hip exoskeleton assistance.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Carnegie Mellon University
Lead sponsor
National Institute for Biomedical Imaging and Bioengineering (NIBIB)
Collaborator
University of Texas at Austin
Collaborator