AI-ECG Accessory Pathway Localisation Study

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age13-100
SponsorImperial College London

About this trial

This study seeks to validate the real-world accuracy of an AI-based algorithm for identifying the location of an accessory pathway from the 12-lead electrocardiogram

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Referred for EPS procedure as part of their clinical care, with a finding of pre-excitation on their ECG

Manifest pre-excitation on their ECG any time prior to their procedure

Able to give consent

Minimum age 13 years old

Disqualifiers

Unable to give consent

Adults > 100 years old

Children < 13 years old

Patients with known location of their accessory pathway from a previous EP study

Trial population

Patients referred for an electrophysiology study +/- ablation, with evidence of previous pre-excitation on their 12-lead ECG.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

Not listed

Trial groups

100 Participants
are grouped into 1 trial group
Group A: Patients with manifest pre-excitation

Trial outcomes

Primary outcomes

1

Performance and accuracy of the AI-ECG accessory pathway localisation algorithm

Performance metrics of the AI-ECG accessory pathway localisation algorithm, including accuracy, F1-score, sensitivity, specificity, positive and negative predictive values. Benchmarked against the ground truth of human operator assessment from fluoroscopy and/or 3D electroanatomical mapping.

Time frame
At completion of recruitment, anticipated at 18 months

Secondary outcomes

1

Relative performance of the AI-ECG algorithm compared to human estimation

Difference in performance/accuracy between the AI-ECG accessory pathway localisation algorithm and human estimation from the 12-lead ECG

Time frame
At completion of recruitment, anticipated at 18 months
2

Relative performance of the AI-ECG algorithm compared to manual localisation algorithms

Difference in performance/accuracy between the AI algorithm and pre-specified, established manual localisation algorithms (Arruda, Milstein, Pambrun, Boersma, D'Avila and Chiang)

Time frame
At completion of recruitment, anticipated at 18 months
3

Accuracy of the ground truth locations from the human operator compared to the successful ablation location

The ground truth of successful ablation location determined by operator assessment of fluoroscopy ± 3D mapping will be compared to the true ablation location on a complete 3D electroanatomical annular map

Time frame
At completion of recruitment, anticipated at 18 months