ALPs Single ChambEr New Device Study

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorCairdac SA

About this trial

Prospective, non-randomized, multi-center, international study designed to evaluate the initial safety and performance of the ALPS leadless pacemaker when used in patients with bradycardia.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Male or female, ≥ 18 years of age at enrolment

Paroxysmal or permanent high-grade AV block in the presence of Atrial Fibrillation (AF)

Paroxysmal or permanent high-grade AV block in the absence of AF, as an alternative to dual chamber pacing, when dual chamber transvenous pacing system is considered difficult, elevated risk, or not deemed necessary for effective therapy.

Symptomatic bradycardia-tachycardia syndrome or Sinus Node Dysfunction (sinus bradycardia or sinus pauses), as an alternative to atrial or dual chamber pacing, when dual chamber transvenous pacing system is considered difficult, elevated risk, or not deemed necessary for effective therapy.

Disqualifiers

Subject who is entirely pacemaker dependent (escape rhythm <30 bpm).

Subject has an existing or prior pacemaker, ICD, or CRT device implant.

Subject has unstable angina pectoris or has had an acute myocardial infarction (AMI) in the 30 days prior to eligibility assessment.

Subject had recent cardiovascular or peripheral vascular surgery within 30 days prior to enrollment

Trial design

Design model

Single group

Treatments tested in this trial

  • Leadless ventricular pacemaker implantation

    Device

    Participants will undergo leadless ventricular pacemaker implantation providing pacing therapy by the implant and monitoring using the home monitor.

Treatment groups

15 Participants
are divided into 1 treatment group
Group A: ALPS groupExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Rate of device-related serious adverse events

Time frame
3 months
2

Rate of participants with pacing thresholds (PCT) ≤ 2V at 0.4 ms pulse width, and and an increase in PCT from implantation is less than 1.5V, and R-wave amplitudes ≥ 5.0 mV, or a value ≥ the value at implantation

Time frame
3 months

Secondary outcomes

1

Rate of patients with battery voltage above 3930mV

Time frame
From enrollment to 3 months following the implantation.
2

The rate of ALPS system and/or procedure-related major complications

Time frame
24 months
3

The rate of subjects in whom the battery voltage is above 3930mV

Time frame
24 months
4

The rate of subjects with pacing thresholds that are within therapeutic range

Time frame
24 months

Other outcomes

Locations

This trial has no locations.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: