An Automatically Adjusting Prosthetic Socket for People With Transtibial Amputation

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorUniversity of Washington

About this trial

People with leg amputations often experience daily changes in the size (volume) of their residual limb. These daily changes can cause a prosthesis to fit poorly. They can also cause limb problems like pain or skin breakdown. Prosthetic socket systems that accommodate limb volume changes can help address these issues, but they require users to make adjustments throughout the day. The aim of this research is to create a system that will automatically adjust the fit of the socket and create a well-fitting prosthesis for people with leg amputations who experience volume fluctuations when using their prosthesis.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

18 years or older

Unilateral or bilateral trans-tibial amputation at least 12 months prior

Have a limb of length 9 cm or greater

Are capable of at least 5 minutes of continuous walking

Disqualifiers

None

Trial design

Design model

Crossover

Treatments tested in this trial

  • Auto Adjusting Prosthesis

    Device

    Participants will test the auto adjusting prosthesis. The prosthesis will be able to move up to 3 panels built into the socket walls to expand or tighten the socket's fit. The auto adjustments will take place during periods of sitting, standing, or walking. Manual adjustments will also be possible either via the researcher controlling the prosthesis or via the key fob developed in the first aim.

Treatment groups

100 Participants
are divided into 3 treatment groups
Group A: Focus Group TestingNo intervention 0 interventions
Group B: In-Lab, Crossover StudyExperimental treatment 1 intervention
Group C: Out-of-Lab Crossover StudyExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Socket Comfort Score

Participants in Aim 2 and Aim 3 will test various configurations of the auto adjustment algorithm. Socket comfort score will be asked at various time points during testing, and overall changes in this metric will be calculated from the start and end of session.

Time frame
through study completion, an average of 1 year
2

Integral Absolute Error of Control System

Calculated error will be measured through each test session, both in and out of lab.

Time frame
through study completion, an average of 1 year

Secondary outcomes

1

Percent change in Limb Fluid Volume

Participant's limb fluid volume will be measured during the structured in-lab protocol (Aim 2), and changes will be compared against an initial reference point of activity during which no interventions will take place.

Time frame
through study completion, an average of 1 year
2

Residual limb health

Data collected using a standard skin assessment protocol and an IR imaging camera will be used. For IR data, thermal recovery time will be calculated and a difference map of TRT between the beginning and end test condition created

Time frame
Baseline and through study completion, an average of 1 year
3

Prosthesis wear time

Socket fit sensor data will be used

Time frame
Up to 12 weeks
4

Time of activities

Durations of walking, standing, sitting, sitting partially doffed, and doffed will be calculated for each day, using socket fit sensor and pin sensor data

Time frame
Up to 12 weeks

Other outcomes

1

Number of manual socket size adjustments

This will be calculated using motor displacement data

Time frame
Up to 12 weeks
2

Participant socket preference and qualitative interview responses

Information from the end of study interview will be tabulated

Time frame
Through study completion, an average of 1 year

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

University of Washington

Lead sponsor

Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD)

Collaborator