About this trial
WALLAS is a small observational study of 30 adults with complex wounds in the abdominal wall after surgery. All participants will receive negative pressure wound therapy (NPWT) because their treating team considers it appropriate. This treatment uses a sealed dressing connected to a suction device. The study will not decide which treatment participants receive or change their usual care.
The main aim is to find out how the stiffness of the large arteries changes during treatment. Researchers will also examine whether larger reductions in wound size and inflammation are linked to larger reductions in artery stiffness.
An upper-arm cuff device will estimate artery stiffness by measuring how quickly pressure waves travel along the aorta, the body's main artery. Measurements are planned before treatment starts, around day 5, and when the first course of NPWT ends. Blood pressure will be taken into account when interpreting the results.
During planned dressing changes, researchers will record wound depth and, when safe and technically possible, measure the wound cavity using sterile saline. Photographs will document the wound. Results from routine blood tests will provide information about inflammation; no extra blood samples are required for research.
Wound recovery and further treatment will be followed for about six months after NPWT starts. The study will also assess how practical and safe the measurement procedures are. Because there is no comparison group, it cannot determine whether NPWT itself causes any changes in artery stiffness.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age 18 years or older.
Clinically indicated negative pressure wound therapy (NPWT) for a postoperative abdominal wall wound complication.
At least one predefined complexity feature: mesh infection or exposure, purulent drainage, a deep wound cavity, tunneling, undermining, or fascial dehiscence after source control with protected viscera.
Hemodynamic stability sufficient for arterial stiffness measurement.
Disqualifiers
NPWT for a non-abdominal wall wound.
NPWT primarily for temporary open-abdomen management.
Active uncontrolled bleeding.
Untreated osteomyelitis in the wound region.
Trial population
Consecutive adults treated at the University of Debrecen for eligible complex postoperative abdominal wall wound complications requiring clinically indicated negative pressure wound therapy (NPWT).
Trial design
Cohort
Prospective
Treatments tested in this trial
Negative Pressure Wound Therapy (NPWT)
DeviceNegative pressure wound therapy delivered through a sealed wound dressing connected to a negative-pressure system. The treating clinical team selects the device, dressing, pressure settings, mode, dressing-change intervals and treatment duration according to clinical need. NPWT is an observed routine-care treatment and is not assigned or modified by the research protocol. Actual treatment characteristics and changes are recorded.
Treatment groups
Trial outcomes
Primary outcomes
Change in aortic pulse wave velocity (PWVao) from baseline to cessation of the index NPWT episode
Change in aortic pulse wave velocity (PWVao), measured in m/s using the Arteriograph TL2. Each standard-condition session is the mean of the first three valid PWVao acquisitions. The primary estimate is the mean arterial pressure (MAP)-adjusted T2-minus-T0 difference, with a 95% confidence interval, from a random-intercept mixed model incorporating T0, T1 and T2, categorical visit, and separate within-person and between-person MAP components. Observed unadjusted T0-T2 paired changes will also be reported. A negative change indicates lower measured arterial stiffness. T0 precedes foam placement. T2 is assessed before planned definitive closure and reflects cessation of the index NPWT episode for any reason, not necessarily wound healing.
Secondary outcomes
Association between PWVao change and percentage wound-cavity volume reduction
Prespecified Model A coefficient relating T2-minus-T0 PWVao change (m/s) to percentage wound-cavity volume reduction (PVR), adjusted for T2-minus-T0 mean arterial pressure (MAP) change. PVR = 100 x (V0 - V2)/V0, using saline-fill volumes in mL. Report m/s per 10-percentage-point greater PVR, with 95% CI and a supplementary nominal P value when estimable. Require standard awake, interpretable T0-T2 vascular pairs, matched MAP, and valid same-encounter vascular-volume pairs at both visits with V0 \> 0. Retain negative PVR and valid pairs flagged for debridement or other wound-altering procedures. Missing or unmeasurable volumes are not assigned zero or 100% reduction. Fit only with sufficient predictor variation, a full-rank design, positive residual degrees of freedom and finite standard errors and confidence intervals, as prespecified; otherwise report individual data without a regression estimate.
Change in native aortic augmentation index (AIxao)
Native aortic augmentation index (AIxao) measured using the Arteriograph TL2 at T0, T1 and T2. Each session value is the mean of the first three valid AIxao acquisitions, with technical validity assessed independently of PWVao. Native values are expressed as percentages and changes as percentage points. The main contrast is the T2-minus-T0 difference, adjusted for concurrent heart rate using the prespecified longitudinal mixed model, with a 95% confidence interval. Heart rate is obtained from the same acquisitions used for AIxao. No conversion to AIx at a standardized heart rate of 75 beats/min is performed.
Percentage reduction in saline-fill wound-cavity volume
Arithmetic mean of patient-specific percentage volume reductions (PVR), each 100 x (V0 - V2)/V0, with a two-sided t-based 95% CI when at least two valid pairs permit calculation. This is not the ratio of group mean volumes. Report n, SD, median and IQR as supporting summaries. Use valid same-encounter saline-fill volumes and V0 \> 0. Negative PVR is retained. Debridement, mesh procedures and deliberate reopening are flagged. No reproducibly fillable residual cavity or loss of the operational filling endpoint during healing is a distinct reason for missing volume, not an assumed zero; a closed wound also has no unmeasured zero. T1 is supportive. The PWVao-PVR association is specified as a separate secondary outcome.
Change in C-reactive protein concentration
Arithmetic mean signed T2-minus-T0 CRP change in mg/L on the raw scale, with a two-sided t-based 95% CI when at least two valid pairs permit calculation. Report n, SD, median and IQR as supporting summaries; negative change indicates a decrease. Select the closest routine collection by absolute time within +/-24 hours of each vascular assessment; ties favor the earlier sample. Record collection times and signed intervals. Change and Model B require two distinct selected blood collection events; reused samples make change missing. Do not substitute another sample to force a pair or draw extra research blood. T1 is supportive. Secondary Model B relates PWVao change to signed CRP change/10 and MAP change, with the raw-scale slope in m/s per 10 mg/L higher signed CRP change, 95% CI and a supplementary nominal P value when estimable. It is an analysis, not an additional outcome.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Dávid Ágoston Kovács
Lead sponsor
University of Debrecen
Sponsor institution
This trial is not recruiting at the moment. You can still explore other options: