Artificial Intelligence-enabled Management of Atrial Fibrillation(ABLE-AF Trial)

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorKorea University Anam Hospital

About this trial

Atrial fibrillation (AF) is the most common type of irregular heartbeat in adults. People with AF may also have other heart problems, including reduced heart pumping function or diseases affecting the heart muscle or heart valves. Identifying these problems early is important because the condition of the heart can affect treatment decisions and long-term care.

An ultrasound examination of the heart, called transthoracic echocardiography (TTE) or an echocardiogram, is commonly used to check how well the heart pumps blood and to look for structural problems, such as heart valve disease. However, an echocardiogram requires special equipment and trained healthcare professionals to perform and interpret the examination. Because of these requirements, it may not always be available when needed. This can be particularly challenging in situations where heart function needs to be evaluated quickly, such as when a patient with AF has a very fast heart rate. Delays may also occur in outpatient settings because of limited availability of echocardiography.

Artificial intelligence (AI) technology may provide an additional way to identify patients who are more likely to have heart problems and who may benefit from further evaluation. A standard 12-lead electrocardiogram (ECG) is a simple and widely available test that records the electrical activity of the heart. AI-based computer programs can analyze information contained in an ECG that may not be easily recognized through routine interpretation.

This study will use two AI-based ECG programs, called AiTiALVSD and AiTiALVDD. AiTiALVSD analyzes a standard 12-lead ECG to identify patients who may have reduced heart pumping function. Previous studies have evaluated this program in different clinical settings, including patients with AF and a fast heart rate.

AiTiALVDD analyzes the ECG for signs that may be associated with difficulty in the heart relaxing and filling with blood. Problems with heart relaxation and filling may occur in several types of heart disease, including heart valve disease, abnormal thickening of the heart muscle, heart disease related to high blood pressure, diseases affecting the heart muscle, and coronary artery disease. Importantly, some patients may have these conditions even when the heart's overall pumping function is normal. Therefore, evaluating only pumping function may not identify all patients who have important underlying heart disease.

By using AiTiALVSD and AiTiALVDD together, this study aims to evaluate a broader AI-based approach to identifying heart problems in patients with AF. AiTiALVSD may help identify patients who are more likely to have reduced heart pumping function, while AiTiALVDD may provide additional information about possible problems with heart relaxation and filling. A high-risk result from AiTiALVDD may serve as a signal that further heart evaluation should be considered, including evaluation for significant heart valve disease or other underlying structural heart conditions.

The purpose of this study is to evaluate whether using these two AI-based ECG programs together can help identify patients with AF who may have previously unrecognized problems with heart function or underlying heart disease. Patients identified by the AI analysis as being at higher risk may receive further evaluation as appropriate to determine whether additional heart disease is present.

The study will also evaluate the clinical usefulness of this AI-based ECG approach in routine care. The goal is not to replace an echocardiogram or a physician's clinical assessment. Instead, AI-based ECG analysis may serve as an additional screening tool to help healthcare professionals identify patients who may benefit from further cardiac testing.

By using information from a routinely performed ECG, this approach may help support earlier and more efficient evaluation of heart function and underlying heart disease in patients with AF. The results of this study will help determine whether combining AiTiALVSD and AiTiALVDD can provide useful information for deciding which patients may need additional cardiac evaluation and whether this approach can improve the process of identifying clinically important heart conditions.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Atrial fibrillation (AF) with rapid ventricular response confirmed on the day of screening or within 90 days before screening.

Rapid ventricular response is defined as (i) a ventricular rate ≥110 bpm or (ii) a ventricular rate ≥100 bpm with related symptoms.

AF can be confirmed by any guideline-accepted electrocardiographic (ECG) method, including 12-lead ECG, Holter ECG, or single-lead ECG (e.g., patch ECG or smartwatch).

AF must be documented for at least 10 seconds on a 12-lead ECG or at least 30 seconds on Holter or single-lead ECG.

Disqualifiers

Left ventricular ejection fraction (LV EF) assessed by transthoracic echocardiography (TTE) within the past 6 months.

If TTE was performed at another institution within the past 6 months, this exclusion criterion applies only when objective imaging data confirming LV EF are available.

Hemodynamically unstable patients requiring immediate direct current cardioversion.

Acute decompensated heart failure requiring immediate hospitalization.

Trial design

Design model

Parallel

Treatments tested in this trial

  • ECG Analysis Software AiTiALVDD

    Device

    * Classification code (grade): B2ABXA1(3) * Mechanism of action: When biosignal data (raw 12-lead ECG data) measured by an ECG device are automatically transmitted or uploaded, an artificial intelligence algorithm displays a score and risk level for the likelihood of left ventricular diastolic dysfunction, for use as a diagnostic aid. Analyzed ECGs can be stored in HL7 aECG XML, JPG, or DICOM format.

  • ECG Analysis Software AiTiALVSD

    Device

    * Classification code (grade): E01020.01(2) * Mechanism of action: When biosignal data (12-lead ECG) from an ECG device are automatically transmitted, or uploaded by the user, this software applies an artificial intelligence algorithm to the ECG data to predict the likelihood of left ventricular systolic dysfunction and displays the analysis results on a web-based screen.

Treatment groups

1,006 Participants
are divided into 2 treatment groups
Group A: Conventional TreatmentActive comparator 1 intervention
Group B: AI-Guided TreatmentExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Major adverse cardiovascular events (MACE), a composite outcome

Major adverse cardiovascular events (MACE) will be assessed as a composite outcome comprising all-cause death, cardiovascular death, stroke (ischemic or hemorrhagic), acute coronary syndrome, and cardiovascular hospitalization. The outcome will be reported as the number of participants experiencing at least one of these events during the follow-up period. Participants experiencing multiple component events will be counted only once in the composite outcome.

Time frame
1year

Secondary outcomes

1

Number of Participants with All-Cause Death

The number of participants who die from any cause during the follow-up period will be assessed. Each participant will be counted only once. Unit of Measure - Number of participants

Time frame
1year
2

Number of Participants with Stroke (Ischemic or Hemorrhagic)

The number of participants experiencing at least one ischemic or hemorrhagic stroke during the follow-up period will be assessed. Each participant will be counted only once, regardless of the number of stroke events. Unit of measure - number of participants

Time frame
1year
3

Number of Participants with Acute Myocardial Infarction

The number of participants experiencing at least one acute myocardial infarction during the follow-up period will be assessed. Each participant will be counted only once, regardless of the number of events. Unit of Measure- Number of participants

Time frame
1year
4

Number of Participants Hospitalized for Heart Failure

The number of participants experiencing at least one hospitalization for heart failure during the follow-up period will be assessed. Each participant will be counted only once, regardless of the number of hospitalizations. Unit of Measure- Number of participants

Time frame
1year

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: