Artificial Intelligence Integration in Breast Cancer Screening: The ANIHTA Study

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorFondazione Policlinico Universitario Agostino Gemelli IRCCS

About this trial

The goal of this observational study is to evaluate how artificial intelligence (AI) can be integrated into an organized breast cancer screening program for women aged 50-74 years undergoing mammography screening.

The main questions it aims to answer are:

* Can an AI-based workflow that identifies selected mammograms for review by a third radiologist improve or maintain the cancer detection rate compared with the current AI-supported double-reading workflow? * How would this AI-based workflow affect recall rates, biopsy referrals, false-positive results, interval cancers, radiologists' workload, and the number of cases requiring third-reader review?

Researchers will compare the currently used screening strategy, in which mammograms are independently read by two radiologists with AI support, with an alternative AI-based strategy reconstructed using a target trial emulation approach. In the alternative strategy, predefined AI score thresholds will be used to identify selected cases for an offline review by an independent third radiologist.

Participants will not be asked to undergo additional examinations or changes to their clinical care. Researchers will use routinely collected mammography screening data, AI scores, radiologists' readings, screening outcomes, and follow-up information. The alternative AI-based screening workflow will be evaluated retrospectively and will not affect participants' screening results or clinical management.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Women aged 50 to 74 years at the time of screening who underwent mammography within the organized breast cancer screening program of Azienda Sanitaria Locale Roma 2 during the predefined historical observation period.

Mammography examinations must have digital images suitable for retrospective analysis with Lunit INSIGHT MMG.

Linked outcome information required to determine study endpoints must be available.

Disqualifiers

Women younger than 50 years or older than 74 years at the time of screening.

Mammography examinations lacking essential image data or outcome information required for AI re-analysis or endpoint classification.

Mammography examinations that cannot be linked to clinical records or cancer registry data when such linkage is required for outcome ascertainment.

Trial population

The study population is drawn from the organized breast cancer screening program of the Local Health Unit (LHU) Roma 2 in Rome, Italy. The retrospective cohort consists of women who underwent mammography within this population-based screening program during the historical observation period. A separate prospective component includes healthcare professionals involved in the organization, management, clinical delivery, or evaluation of the same screening program, who will participate in a Discrete Choice Experiment assessing preferences regarding AI-supported screening.

Trial design

Design model

Cohort

Time perspective

Other

Treatments tested in this trial

  • Artificial intelligence-based software for mammography

    Device

    Lunit INSIGHT MMG is an artificial intelligence-based software for mammography that generates a continuous malignancy score ranging from 0 to 100. In the retrospective breast screening cohort, AI scores will be used to assess diagnostic performance and to analytically reconstruct alternative AI-supported screening workflow strategies. Strategy A represents the observed routine AI-supported double-reading workflow without third-reader arbitration. Strategy B represents an emulated AI-triggered workflow in which prespecified AI score thresholds (AIpt and AInt) are used to identify selected examinations for offline third-radiologist assessment or direct recall classification. Strategy B will be reconstructed retrospectively and will not be prospectively applied to clinical decision-making or patient management.

  • Discrete Choice Experiment on AI-Supported Breast Cancer Screening

    Other intervention

    Healthcare professionals involved in the organized breast cancer screening program will complete a structured Discrete Choice Experiment (DCE) designed to assess preferences regarding the organizational and clinical integration of artificial intelligence into breast cancer screening. The DCE will evaluate acceptability, usability, trust in AI, perceived utility, satisfaction, and preferences regarding alternative characteristics of AI-supported screening workflows. The survey is observational and does not modify clinical practice or patient management.

Treatment groups

200,075 Participants
are divided into 2 treatment groups
Group A: Retrospective Breast Screening Cohort1 intervention
Group B: Healthcare Professionals DCE Cohort1 intervention

Trial outcomes

Primary outcomes

1

Cancer Detection Rate

Cancer detection rate (CDR) will be defined as the number of confirmed breast cancers classified as screen-detected under each strategy per 1,000 eligible screening examinations in the independent validation set. The primary non-inferiority measure will be the ratio of CDR under the emulated AI-triggered third-reader-augmented workflow (Strategy B) to CDR under the observed routine AI-supported double-reading workflow without third-reader arbitration (Strategy A). A relative non-inferiority margin of 0.85 will be used, corresponding to a maximum acceptable relative reduction of 15% in CDR under Strategy B. Non-inferiority will be concluded if the lower bound of the two-sided 95% confidence interval for the CDR ratio is greater than 0.85. The absolute difference in CDR between Strategy B and Strategy A, expressed per 1,000 screening examinations, will also be reported as a complementary measure of clinical impact.

Time frame
From the index screening mammography examination through 24 months of follow-up

Secondary outcomes

1

Sensitivity, Specificity, Positive Predictive Value, Negative Predictive Value, False-Positive Rate, and False-Negative Rate of the AIpt Threshold

The AI-positive threshold (AIpt), derived in the prespecified derivation set and applied without recalibration to the independent validation set, will be evaluated in terms of sensitivity, specificity, positive predictive value, negative predictive value, false-positive rate, and false-negative rate, with corresponding 95% confidence intervals.

Time frame
From the index screening mammography examination through 24 months of follow-up
2

Sensitivity, Specificity, Positive Predictive Value, Negative Predictive Value, False-Positive Rate, and False-Negative Rate of the AInt Threshold

The AI-negative threshold (AInt), derived in the prespecified derivation set and applied without recalibration to the independent validation set, will be evaluated in terms of sensitivity, specificity, positive predictive value, negative predictive value, false-positive rate, and false-negative rate, with corresponding 95% confidence intervals.

Time frame
From the index screening mammography examination through 24 months of follow-up
3

Proportion of Screening Examinations Requiring Emulated Third-Reader Arbitration Under Strategy B

The emulated third-reader arbitration rate will be defined as the proportion of eligible screening examinations meeting the prespecified Strategy B criteria for offline third-radiologist assessment. These include concordant negative examinations with an AI score equal to or greater than AIpt and discordant examinations with an AI score equal to or lower than AInt.

Time frame
At the index screening mammography examination
4

Difference in Biopsy Referral Rate Between Strategy B and Strategy A

Biopsy referral rate will be defined as the proportion of eligible screening examinations leading to recommendation or performance of tissue sampling during the diagnostic work-up. The biopsy referral rate under the emulated Strategy B workflow will be compared with that under the observed Strategy A workflow.

Time frame
From the index screening mammography examination through completion of the diagnostic work-up

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: