About this trial
ROCKET evaluates the clinical performance of an investigational version of neos™, a non-invasive device that uses a virtual-reality headset and eye tracking to assess binocular vision-how the two eyes work together.
The study compares neos™ results with standard clinical examinations for three functions: sensory fusion, the ability to combine images from both eyes into a single image; stereopsis, the perception of depth from differences between the images seen by each eye; and suppression, reduced awareness of visual input from one eye during binocular viewing.
Approximately 184 patients aged 3 years and older who require a clinical binocular vision assessment will participate at ophthalmology centres in Switzerland. Each participant will undergo standard clinical testing and a neos™ examination during a single study visit. During the neos™ examination, visual stimuli are presented through the headset while the device records eye movements and pupil responses.
The main objective is to determine how accurately neos™ identifies the presence or absence of sensory fusion, stereopsis and central suppression compared with the clinical reference assessments. Additional analyses will compare fusion-related measurements, characterize stereopsis and suppression, and explore relationships between neos™ measurements and clinical findings.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Patients scheduled to undergo, or having undergone, a clinical binocularity assessment at the investigational site on the same day.
Age ≥3 years at the time of consent.
Ability to understand and comply with the examination, in the investigator's opinion.
Written informed consent provided by the participant and/or legal representative.
Disqualifiers
Best-corrected visual acuity worse than 0.2 decimal (0.7 logMAR) in either eye.
Refractive error beyond the range that can be corrected by the system, including lens inserts and the use of contact lenses.
Trial design
Single group
Treatments tested in this trial
Manual binocularity assessment
Diagnostic testStandard clinical binocular vision examination performed by a trained healthcare professional. Assessments may include prism bar testing, Bagolini striated lenses, Worth 4-Dot testing and standardized stereotests, selected according to clinical findings and participant cooperation. Suitable reference information is obtained for each primary outcome. The examination lasts approximately 30 minutes.
Treatment groups
Trial outcomes
Primary outcomes
Sensitivity and Specificity of neos™ for Detecting Sensory Fusion
Sensitivity and specificity of the neos™ sensory fusion classification (present/absent) compared with the clinical reference classification. Reference sensory fusion is present when binocular single perception is demonstrated using Bagolini striated lenses or Worth 4-Dot testing. Performance is calculated from paired classifications and reported with two-sided 95% exact Clopper-Pearson confidence intervals.
Sensitivity and Specificity of neos™ for Detecting Stereopsis
Sensitivity and specificity of the neos™ stereopsis classification (present/absent) compared with standard clinical stereotesting. For both methods, stereopsis is classified as present when stereoscopic disparity of 600 arcseconds or finer is detected. Performance is calculated from paired classifications and reported with two-sided 95% exact Clopper-Pearson confidence intervals.
Sensitivity and Specificity of neos™ for Detecting Central Suppression
Sensitivity and specificity of the neos™ central (foveal) suppression classification (present/absent) compared with the clinical reference classification. The reference uses a prespecified hierarchical rule: suppression is absent when stereopsis or sensory fusion is present. When both are absent, suppression is present if clinical testing demonstrates failure to perceive input from one eye; otherwise, it is absent. Performance is reported with two-sided 95% exact Clopper-Pearson confidence intervals.
Locations
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
machineMD AG
Lead sponsor
Kantonsspital Aarau
Collaborator
Hôpital ophtalmique Jules-Gonin (HOJG)
Collaborator
This trial is not recruiting at the moment. You can still explore other options: