Assessment of Hemodynamic Responses at Adequate Depth of Anesthesia Using Bispectral Index During Rapid Sequence Intubation in the Emergency Department

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorAkdeniz University Hospital

About this trial

Rapid sequence intubation (RSI) is the standard approach for emergency airway management in critically ill patients requiring endotracheal intubation. Laryngoscopy and tracheal intubation may provoke significant hemodynamic responses, including increases in heart rate and blood pressure, which may adversely affect patients with severe neurological or cardiovascular disease.

Although hemodynamic responses during tracheal intubation have been extensively investigated in the anesthesiology literature, evidence from emergency department settings remains limited. Furthermore, previous studies have rarely confirmed whether an adequate depth of anesthesia had been achieved before laryngoscopy, making interpretation of hemodynamic responses difficult.

The aim of this prospective observational study is to evaluate hemodynamic responses during rapid sequence intubation in adult emergency department patients after confirming adequate depth of anesthesia using bispectral index (BIS) monitoring. Heart rate and blood pressure will be recorded before induction, during intubation, and after successful endotracheal intubation, allowing objective assessment of the hemodynamic response under confirmed adequate anesthetic depth.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

None

Disqualifiers

None

Trial population

Adult patients (≥18 years) requiring rapid sequence intubation (RSI) in the emergency department for airway management. All eligible patients underwent bispectral index (BIS) monitoring before laryngoscopy, and hemodynamic responses were evaluated after confirmation of adequate depth of anesthesia.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Bispectral Index (BIS) Monitoring

    Device

    Bispectral index monitoring is used to assess the depth of anesthesia before laryngoscopy. Endotracheal intubation is performed after an adequate BIS value has been achieved.

Treatment groups

200 Participants
are divided into 1 treatment group
Group A: Emergency Department Patients Undergoing Rapid Sequence Intubation1 intervention

Trial outcomes

Primary outcomes

1

Change in Diastolic Blood Pressure Following Rapid Sequence Intubation

Diastolic Blood pressure (MAP) measured before induction, immediately after endotracheal intubation, and at 5, 10, and 15 minutes after intubation in patients with BIS-confirmed adequate depth of anesthesia.

Time frame
Baseline, immediately after intubation, and 5, 10, and 15 minutes after intubation
2

Change in Systolic Blood Pressure Following Rapid Sequence Intubation

Systolic Blood pressure measured before induction, immediately after endotracheal intubation, and at 5, 10, and 15 minutes after intubation in patients with BIS-confirmed adequate depth of anesthesia.

Time frame
Baseline, immediately after intubation, and 5, 10, and 15 minutes after intubation
3

Change in Heart Rate Following Rapid Sequence Intubation

Heart Rate measured before induction, immediately after endotracheal intubation, and at 5, 10, and 15 minutes after intubation in patients with BIS-confirmed adequate depth of anesthesia.

Time frame
Baseline, immediately after intubation, and 5, 10, and 15 minutes after intubation

Secondary outcomes

Other outcomes