About this trial
Radiotherapy, a cornerstone of comprehensive cancer treatment, relies heavily on clinician expertise for target volume contouring and treatment planning. Consequently, clinical practice is often constrained by procedural bottlenecks, inter-observer variability, and prolonged iterative feedback cycles. Although current artificial intelligence (AI) models have demonstrated progress in automated contouring, key limitations persist, including insufficient integration of multimodal clinical text, a lack of closed-loop dosimetric feedback, and limited generalizability across complex cancer types.
This study aims to develop and validate RATA (Radiotherapy Treatment Multi-Agent Assistant), a novel large model system powered by a collaborative multi-agent architecture. Driven by Large Language Model (LLM) decision engines, RATA processes pathological imaging, electronic health records (EHR), and multimodal medical data to construct a end-to-end, fully automated closed-loop pipeline encompassing "target contouring, plan design, dosimetric evaluation, and reflective refinement." Innovatively breaking through traditional unidirectional radiotherapy workflows, the system establishes a dosimetric feedback-driven adaptive iteration mechanism, leveraging dose distribution outcomes to guide multi-agent dynamic fine-tuning of target volumes, thereby mimicking the collaborative clinical logic between senior radiation oncologists and medical physicists.
For validation, this study adopts a multi-center, three-stage clinical validation framework-comprising multi-center retrospective validation, human-AI collaborative efficacy assessment, and a prospective randomized controlled trial (RCT)-to comprehensively evaluate the system's performance in improving contouring precision, mitigating experience-dependent disparities across clinician seniority, and reducing total workflow processing time. Implementation of the RATA platform holds potential to eliminate redundant operational steps, enabling a minute-level "scan-to-treat" response. Furthermore, its natural language interaction interface optimizes human-AI collaboration and substantially reduces clinical workload. Overall, this study not only establishes a standardized, intelligent assistance paradigm for precision radiation oncology but also provides essential evidence-based support and technological foundations for the clinical translation of multimodal AI in complex cancer management.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Pathologically confirmed malignant neoplasm requiring definitive or adjuvant radiotherapy.
Availability of verified pathology report.
Availability of baseline imaging examinations and diagnostic reports.
Availability of standardized and complete clinical electronic health records.
Disqualifiers
Incomplete clinical, imaging, or follow-up data.
Presence of multiple primary malignancies.
Patients scheduled for salvage or palliative radiotherapy.
Trial design
Parallel
Treatments tested in this trial
RATA (Radiotherapy Treatment Multi-Agent Assistant) System
DeviceAn AI-driven multi-agent platform utilizing large language model decision engines to automatically perform target volume contouring, dosimetric plan generation, evaluation, and adaptive refinement for cancer radiotherapy.
Standard Radiotherapy Planning Workflow
Other interventionConventional offline radiation therapy planning workflow, where target volume contouring and treatment planning are manually performed by radiation oncologists and medical physicists according to routine institutional protocols.
Treatment groups
Trial outcomes
Primary outcomes
Total Closed-Loop Workflow Duration
Total time (in minutes) required for the complete end-to-end radiotherapy planning closed-loop workflow, measured from initial CT simulation scan completion to final clinical treatment plan approval and readiness for first fraction delivery.
Secondary outcomes
Clinical Acceptance Rate of Treatment Plans
Percentage of treatment plans rated as clinically acceptable (score ≥3 on a 5-point Likert scale) by senior radiation oncologists without substantial manual re-planning.
Planning Time and Workload Reduction Rate
Total clinician active manual intervention time (contour editing and plan optimization duration in minutes) and percentage of labor time saved compared to the standard manual workflow.
Contouring Accuracy Metrics and Dosimetric Parameters
Geometric similarity metrics including Dice Similarity Coefficient (DSC), 95% Hausdorff Distance (HD95), and Average Surface Distance (ASD); dosimetric indicators including Target Coverage (V95%), Conformity Index (CI), Homogeneity Index (HI), and Organs-at-Risk (OAR) dose constraints.
First Setup Verification Pass Rate
Proportion of participants passing the initial positional setup and position verification check (e.g., CBCT/IGRT alignment) prior to the first fraction delivery on the treatment couch.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
zhaoxiaohui
Lead sponsor
Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University
Sponsor institution
The First Affiliated Hospital, Guangzhou University of Traditional Chinese Medicine
Collaborator
Sun Yat-Sen University Cancer Center
Collaborator
First Affiliated Hospital, Sun Yat-Sen University
Collaborator
Zhoukou Central Hospital
Collaborator
Union Hospital, Tongji Medical College, Huazhong University of Science and Technology
Collaborator
Shenshan Medical Center of Sun Yat-sen Memorial Hospital
Collaborator
This trial is not recruiting at the moment. You can still explore other options: