Bio Impedance Monitoring as a Tool to Assess Fluid Status in the Pediatric Surgical Patient? (PedFluid Study)

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age1-16
SponsorUniversity Hospital, Antwerp

About this trial

The baseline infusion rate during surgery for pediatric patients still is the 'Holliday and Segar' rule (also known as the 4/2/1 rule) The question arises if this rule is not outdated, since it was calculated based on the caloric need of the pediatric population, calculated for cow milk. The study tends to validate the use of bio impedance measurements for registering fluid shifts in the pediatric surgical patients.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Scheduled for elective surgery or investigation under general anesthesia

Day care or inpatient hospitalisation

Disqualifiers

If sedation is needed instead of general anesthesia

Critically ill patients for urgent surgery

Patients who cannot lie still for performing correct measurements on the bio impedance monitor

No informed consent obtained

Trial design

Design model

Single group

Treatments tested in this trial

  • bio impedance spectroscopy by means of the Body Composition Monitor (Name of the device is BCM from Fresenius Medical Care D GmbH)

    Diagnostic test

    The Body Composition Monitor provides information about the hydration status by a bioimpedance spectroscopy measurement of the body composition from which the level of overhydration can be derived. Four electrodes are used per measurement. All subjects get electrodes attached, following the wrist-ankle approach, in a tetrapolar arrangement. Two electrodes are placed on the hand: one on the wrist, and the second on the dorsal side of the metacarpalia, close to the phalanges. The other two electrodes are placed on the foot: one on the ankle, and the second on the dorsal side of the metatarsals, close to the phalanges of the toes. Age, gender, height, weight and blood pressure are registered in the device before starting the measurement. If the quality calculated by BCM is \< 60%, the measurement will be repeated again. Measurements are taken under supervision of a trained technician or nurse.

Treatment groups

100 Participants
are divided into 1 treatment group
Group A: Bio impedance spectroscopy in children scheduled for elective surgery under general anesthesiaOther 1 intervention

Trial outcomes

Primary outcomes

1

total body water

sum of intracellular water and extracellular water, calculated in liter

Time frame
measurements with BCM will be done pre-surgery
2

total body water

sum of intracellular water and extracellular water, calculated in liter

Time frame
measurements with BCM will be done within 6 hours post-surgery for patients in day care
3

total body water

sum of intracellular water and extracellular water, calculated in liter

Time frame
measurements with BCM will be done within 24 hours post-surgery for hospitalized patients

Secondary outcomes

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.