Bioimpedance and Multiparametric Ultrasound-Guided Fluid Management After Kidney Transplantation

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorHospital Universitario Ramon y Cajal

About this trial

After a kidney transplant, the amount of fluid in the body must be carefully balanced. Too much fluid can accumulate in the lungs, the tissues and the new kidney itself and may delay its recovery; too little fluid can also damage it. In current practice, doctors judge fluid status mainly by physical examination, body weight and urine output, which are imprecise and often late signs.

Two painless bedside tests can measure fluid status more accurately: bioimpedance, which estimates excess body water through skin electrodes, and ultrasound of the lungs, the large abdominal veins and the transplanted kidney. In a previous study by our group, these tests detected fluid overload that physical examination missed. Whether using their results to guide treatment actually improves the outcome of the transplant is unknown.

This trial will compare two ways of managing fluids during the first month after transplantation: one guided by these tests and a treatment algorithm, and one based on usual clinical assessment. The aim is to find out whether test-guided management improves survival, reduces the need for dialysis in the first week and leads to better kidney function at one month.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

CKD stage 5.

Kidney-only transplant from a deceased donor (brain death or circulatory death, with or without normothermic regional perfusion).

Two-step informed consent.

Disqualifiers

Multi-organ transplant.

ICU admission on mechanical ventilation.

Implanted electronic device or major amputation.

Fibrotic lung disease or extensive thoracic dressings.

Trial design

Design model

Parallel

Treatments tested in this trial

  • Multiparametric assessment

    Diagnostic test

    Bioimpedance and Multiparametric Ultrasound-Guided Fluid Management

  • Structured usual care

    Other intervention

    Usual clinical management guided by standardised physical examination, daily weight and fluid balance, following a predefined clinical-criteria action protocol (respiratory compromise, signs of venous congestion, overload without respiratory compromise, suspected depletion, euvolaemia), with the same common background protocol. The same bioimpedance and ultrasound assessments are performed on the same schedule, but results are not shown to the treating team, except for critical findings, which are disclosed immediately.

Treatment groups

650 Participants
are divided into 2 treatment groups
Group A: Experimental armExperimental treatment 2 interventions
Group B: StructuredNo intervention 0 interventions

Trial outcomes

Primary outcomes

1

Hierarchical composite of death, graft loss, sustained dialysis and eGFR (win ratio)

Each intervention participant is compared with each control participant within strata (centre, donor type), moving to the next level only if tied: (1) all-cause death (earlier is worse); (2) graft loss, defined as permanent return to dialysis or transplantectomy (earlier is worse); (3) sustained dialysis within 7 days after reperfusion, excluding a single session in the first 24 h for isolated hyperkalaemia (more sessions is worse); (4) eGFR at 1 month, CKD-EPI 2021 creatinine equation (higher is better). Reported as stratified win ratio with 95% CI (Finkelstein-Schoenfeld test), win odds and net benefit.

Time frame
Day 30 post-transplant (dialysis assessed up to day 7; eGFR measured on days 28-35)

Secondary outcomes

1

Delayed graft function, by dialysis and functional (CRR2) definitions

Proportion of participants requiring any dialysis within the first 7 days after transplantation, and proportion with a creatinine reduction ratio on day 2 below 30%.

Time frame
Day 2 (CRR2) and up to day 7 post-transplant (dialysis)
2

Number of dialysis sessions

Number of dialysis sessions and days to last dialysis within the first 7 days.

Time frame
Up to day 7 post-transplant
3

Length of stay

Days from transplantation to discharge from the index admission, analysed with death as a competing event.

Time frame
Up to 90 days post-transplant
4

Days alive and out of hospital at 30 days

Number of days alive and out of hospital within the first 30 days after transplantation.

Time frame
Day 30 post-transplant

Other outcomes

1

Time to detection of fluid overload

Paired comparison of the time from randomisation to first detection of fluid overload by the multiparametric strategy versus physical examination, against a reference standard adjudicated by a blinded committee, with latent class analysis as a sensitivity analysis. All participants.

Time frame
From randomisation to day 7 post-transplant
2

Diagnostic accuracy of each method

Sensitivity, specificity and likelihood ratios of bioimpedance, VExUS, graft venous pulsatility, lung ultrasound and physical examination against the adjudicated reference standard.

Time frame
Days 1, 3 and 7 and month 1 post-transplant
3

Inter- and intra-observer reliability

Weighted kappa, Gwet AC1/AC2 and intraclass correlation coefficient (2,1) for VExUS grade, graft venous pulsatility, lung ultrasound B-lines and bioimpedance; minimal detectable change.

Time frame
Days 1, 3 and 7 and month 1 post-transplant
4

Intervention fidelity

Proportion of assessments in the intervention arm followed by algorithm-concordant management.

Time frame
Days 1, 3 and 7, pre-discharge and month 1 post-transplant

Locations

This trial has no locations.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Hospital Universitario Ramon y Cajal

Lead sponsor

Hospital San Carlos, Madrid

Collaborator

Hospital Universitari de Bellvitge

Collaborator

This trial is not recruiting at the moment. You can still explore other options: