Body Composition and Setup Errors in Radiotherapy

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorShijiazhuang People's Hospital

About this trial

This single-center prospective cohort study investigates the association between body composition parameters and setup errors in 120-150 patients receiving radiotherapy with thermoplastic mask immobilization. Body composition (skeletal muscle mass, body fat percentage, phase angle, fat-free mass) will be measured using bioelectrical impedance analysis at baseline and at fraction 20. Setup errors (six degrees of freedom) will be recorded via daily cone-beam computed tomography. The primary outcome is the association between baseline body composition and setup errors. Secondary outcomes include the relationship between body composition changes during radiotherapy and setup error evolution, and identification of threshold values for clinically significant setup error increases. This study will provide evidence on whether body composition-beyond BMI-predicts radiotherapy setup accuracy, potentially enabling personalized immobilization and image-guided strategies.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Pathologically confirmed malignancy

Age ≥18 years

Receiving radical or adjuvant intensity-modulated radiotherapy (IMRT) with planned ≥25 fractions

Immobilized with thermoplastic mask

Disqualifiers

Metal implants (pacemaker, artificial joints) affecting bioelectrical impedance analysis (BIA) measurements

Severe edema or ascites

Inability to cooperate with immobilization or CBCT scanning

Radiotherapy interruption >5 fractions

Trial population

Patients with pathologically confirmed malignancies receiving radical or adjuvant intensity-modulated radiotherapy at Shijiazhuang People's Hospital.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

Not listed

Trial groups

150 Participants
are grouped into 2 trial groups
Group A: High Muscle Mass Group
Group B: Low Muscle Mass Group

Trial outcomes

Primary outcomes

1

setup errors

Six-degree-of-freedom setup errors (Tx, Ty, Tz, Rx, Ry, Rz) measured by cone-beam computed tomography (CBCT).

Time frame
Through study completion, an average of 6 months.

Secondary outcomes

1

Change in Skeletal Muscle Mass

Change in skeletal muscle mass (SMM) from baseline (T0) to radiotherapy fraction 20 (T1), measured by multi-frequency bioelectrical impedance analysis (BIA). SMM is expressed in kilograms (kg).

Time frame
Baseline and fraction 20 (approximately 4 weeks after baseline)
2

Change in Body Fat Percentage

Change in body fat percentage (BFP) from baseline (T0) to radiotherapy fraction 20 (T1), measured by multi-frequency bioelectrical impedance analysis (BIA). BFP is expressed as a percentage (%).

Time frame
Baseline and fraction 20 (approximately 4 weeks after baseline).
3

Change in Phase Angle

Change in phase angle (PhA) from baseline (T0) to radiotherapy fraction 20 (T1), measured by multi-frequency bioelectrical impedance analysis (BIA). PhA is expressed in degrees (°).

Time frame
Baseline and fraction 20 (approximately 4 weeks after baseline)
4

Change in Fat-Free Mass

Change in fat-free mass (FFM) from baseline (T0) to radiotherapy fraction 20 (T1), measured by multi-frequency bioelectrical impedance analysis (BIA). FFM is expressed in kilograms (kg).

Time frame
Baseline and fraction 20 (approximately 4 weeks after baseline)

Other outcomes

Locations

This trial has no locations.