About this trial
This observational cross-sectional study aims to examine the relationship between body composition, functional capacity, and respiratory muscle endurance in individuals with obesity and a restrictive ventilatory pattern. A total of 100 adults aged 25-60 years with a body mass index (BMI) ≥30 kg/m² and restrictive pulmonary function findings will be enrolled. Participants will evaluate body composition assessment using bioelectrical impedance analysis, pulmonary function testing by spirometry, respiratory muscle strength and endurance measurements, and functional capacity evaluation using the Six-Minute Walk Test (6MWT). The aim of this study is to evaluate the relationships between stem cell count (SCC), a novel anthropometric indicator called WWI, trunk muscle mass, and functional capacity in obese individuals with a restrictive ventilatory pattern.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Individuals aged between 25 and 60 years
Individuals with a body mass index (BMI) ≥ 30 kg/m² according to the World Health Organization (WHO) classification
Individuals demonstrating a restrictive ventilatory pattern (FVC < 80% predicted)
Individuals who voluntarily agree to participate in the study
Disqualifiers
Individuals with a Charlson Comorbidity Index (CCI) score of 3 or higher
Individuals with uncontrolled arrhythmia, hypertension, heart failure, diabetes mellitus, or unstable angina pectoris
Individuals with cooperation impairments, orthopedic, or neurological conditions that may interfere with assessment or treatment
Individuals with a history of lower extremity injury or surgery within the last six months
Trial population
Obese Individuals with Restrictive Ventilatory Pattern
Trial design
Cohort
Prospective
Treatments tested in this trial
Pulmonary Function, Body Composition, and Functional Capacity Assessment
Other interventionParticipants will undergo a comprehensive assessment including pulmonary function testing using spirometry, body composition analysis using bioelectrical impedance analysis (BIA), respiratory muscle strength and endurance evaluation, and functional capacity assessment with the Six-Minute Walk Test (6MWT). Anthropometric measurements including body weight, height, waist circumference, hip circumference, and waist-to-height ratio will also be recorded.
Treatment groups
Trial outcomes
Primary outcomes
Functional capacity
Participants' exercise capacity will be assessed using the Six-Minute Walk Test (6MWT) according to the American Thoracic Society (ATS) guidelines with the Spiropalm 6MWT system (Cosmed, Italy) (ATS, 2002). The test will be performed in a 30-meter indoor corridor following a minimum 10-minute rest period. Heart rate, blood pressure, oxygen saturation, dyspnea, and leg fatigue levels will be recorded before and after the test. Participants will be instructed to walk as fast as possible for six minutes and may rest or terminate the test if severe symptoms occur. Total walking distance will be recorded in meters, and any interruptions or symptoms during the test will be documented.
Respiratory Muscle Endurance
Participants' respiratory muscle endurance will be assessed using an inspiratory muscle training device (POWERbreathe® K-Series K3, POWERbreathe International Ltd, UK). Measurements will be performed in a seated position with a nose clip applied and the device placed in the mouth. The assessment will be conducted using an incremental threshold loading protocol. At the beginning of the test, the threshold pressure will be set at 20% of the participant's maximal inspiratory pressure (MIP). Participants will be instructed to complete 30 breaths over a two-minute period. Individuals who tolerate this level will progress to subsequent stages with gradually increasing loads of 40%, 60%, 80%, and 100% of MIP, respectively. Oxygen saturation and heart rate will be recorded before and after the test using a pulse oximeter. Participants will also be informed that they may remove the device from their mouth and terminate the test at any time in the event of any discomfort or adverse symptoms.
Secondary outcomes
Body fat mass
Participants' body fat mass (kg) will be measured using Bioelectrical Impedance Analysis (BIA). Participants will be informed about the test protocol and instructed to fast for 8-12 hours before the assessment, arrive with an empty bladder, and avoid fluid intake, food consumption, and vigorous physical activity prior to testing. Measurements will be performed during daytime at a room temperature of 25°C. Participants will be assessed while clothed and barefoot after removing their shoes, socks, and all metal accessories.
Forced vital capacity (FVC)
Forced vital capacity (FVC) will be evaluated using a Pulmonary Function Test (PFT) in accordance with the American Thoracic Society (ATS) and European Respiratory Society (ERS) criteria, utilizing the "COSMED Spiropalm 6MWT" device (COSMED, Italy) and its integrated PFT software (ATS \& ERS, 2002). Assessments will be performed in a seated position with back support. To minimize the risk of infection, a disposable mouthpiece and filter will be used for each participant. Values will be recorded both in liters and as percentages (%) of predicted values. Measurements will be repeated three times, and the best value meeting the measurement standards will be recorded.
Ventilation (VE)
Ventilation (VE) will be measured during the Six-Minute Walk Test (6MWT) using the Spiropalm device.
Body muscle mass
Body muscle mass (kg) will be measured using Bioelectrical Impedance Analysis (BIA). Participants will be informed about the test protocol and instructed to fast for 8-12 hours before the assessment, arrive with an empty bladder, and avoid fluid intake, food consumption, and vigorous physical activity prior to testing. Measurements will be performed during daytime at a room temperature of 25°C. Participants will be assessed while clothed and barefoot after removing their shoes, socks, and all metal accessories.
Locations
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: