Three-Dimensional Bracketless Orthodontic Treatment (3D-BOT) Using E-WIRE Versus Conventional Fixed Braces for Mild-to-Moderate Lower Front Tooth Crowding in Adults

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-25
SponsorUniversity of Aleppo

About this trial

This study will compare two fixed orthodontic treatments for mild-to-moderate crowding of the lower front teeth in adults. Participants will be randomly assigned to three-dimensional bracketless orthodontic treatment (3D-BOT), which uses wires bonded directly to the teeth, or conventional braces attached to the front surfaces of the teeth.

The main aim is to compare how tooth alignment changes during the first 24 weeks after appliance placement. Additional assessments will examine changes in tooth position and lower dental arch dimensions, oral and gum health, soft-tissue effects, quality of life and psychosocial well-being, patient experience and satisfaction, pain and painkiller use, appliance failures, time spent on clinical procedures and digital preparation, and changes in teeth and supporting bone. Data will be collected through clinical examinations, digital scans, questionnaires, home diaries and radiographic imaging.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age 18-25 years, inclusive.

Little's Irregularity Index of 3-6 mm in the mandibular anterior segment (teeth 43-33, Fédération Dentaire Internationale [FDI] notation), measured on the pretreatment digital model.

Permanent dentition with clinically stable occlusion and an Angle Class I molar relationship.

Skeletal Class I relationship, defined by an A point-nasion-B point (ANB) angle of 1-4° on the pretreatment lateral cephalogram.

Disqualifiers

Previous orthodontic treatment.

Severe bruxism or a habit of biting hard objects.

Deep bite precluding placement of either study appliance without occlusal interference.

Use of medications or presence of systemic conditions that clearly affect tooth movement or periodontal health.

Trial design

Design model

Parallel

Treatments tested in this trial

  • Conventional Labial Fixed Orthodontic Appliance

    Device

    Mini Master Series metal brackets (American Orthodontics), McLaughlin-Bennett-Trevisi (MBT) prescription with 0.022-inch slots, will be bonded to teeth 45-35, with buccal tubes on 46 and 36. Nickel-titanium (NiTi) archwires will follow the planned sequence (inches): 0.012 at initial appliance placement (APP0); 0.014 at Week 4; 0.016 at Week 8; 0.016×0.022 at Week 12; 0.017×0.025 at Week 16; and 0.019×0.025 at Week 20. Progression requires clinically appropriate engagement without excessive force; otherwise, the current wire will be retained and reassessed. A 0.019×0.025-inch stainless steel wire will be placed after all Week 24 research assessments. IPR will follow the plan locked before randomization. No chains, springs or other auxiliaries directly affecting lower anterior alignment will be used during evaluation. Actual wire changes, delays, repairs and clinically necessary deviations will be documented.

  • 3D-BOT Using E-WIRE Archwires

    Device

    At initial appliance placement (APP0), a round coated E-WIRE (E-Wireligner; nominal size 0.014 inch) will be secured with GC Ortho Connect Flow (GC Orthodontics) from teeth 46 to 36 along a digitally planned posterior occlusal/anterior lingual path. After light curing, the water-soluble coating will be removed with a 60-second water wash. After the Week 8 digital scan, the initial wire and its composite will be removed, and a coated Velodrome E-WIRE (E-Wireligner; nominal size 0.016 × 0.022 inch) will be bonded to the lingual surfaces of teeth 43-33 only, using the same bonding and coating-removal procedures. IPR will follow the plan locked before randomization. No auxiliaries directly affecting lower anterior alignment will be used. Clinically necessary delays, repairs and deviations will be documented.

Treatment groups

40 Participants
are divided into 2 treatment groups
Group A: Conventional Labial Fixed Orthodontic TreatmentActive comparator 1 intervention
Group B: 3D-BOT Using E-WIRE ArchwiresExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Longitudinal change in mandibular anterior Little's Irregularity Index (LII)

LII is the sum of five horizontal displacements between corresponding anatomical contact points of adjacent mandibular anterior teeth (43-33), measured in millimeters on digital models. Decreases from baseline indicate improved alignment.

Time frame
Baseline (T0, before initial appliance placement) and Weeks 4, 8, 12, 16, 20 and 24 after initial appliance placement (APP0).

Secondary outcomes

1

Alignment Progression and Time to Documented Alignment

Mandibular anterior alignment is assessed on digital models using Little's Irregularity Index (LII). Measures include interval LII reduction (mm), improvement rate (mm per four weeks, using actual elapsed intervals), cumulative percentage improvement from baseline, proportion achieving LII ≤1 mm, time (days) from initial appliance placement to the first scan documenting LII ≤1 mm, and area under the LII curve (mm × weeks; trapezoidal rule using scheduled weeks; lower values indicate faster or more complete alignment).

Time frame
Baseline and Weeks 4, 8, 12, 16, 20 and 24 after initial appliance placement. Time to documented alignment: from initial placement up to Week 24.
2

Changes in mandibular arch dimensions

Digital-model changes from baseline (mm) in intercanine cusp-tip width, first-premolar Pont width, first-molar middle-buccal-cusp width and anterior arch depth. Pont points lie at the distal marginal ridge/distal buccal-cusp-slope junctions. Depth is the greatest perpendicular distance from either lower central incisor's most labial incisal-edge point to the first-premolar Pont line.

Time frame
Baseline and Weeks 4, 8, 12, 16, 20 and 24 after initial placement.
3

Changes in lower incisor inclination and protrusion

Changes from baseline on lateral cephalograms in the angles between the lower incisor's long axis and the mandibular plane (gonion-menton, Go-Me) and nasion-point B line (NB), measured in degrees, and the perpendicular distance from its most labial crown point to NB, measured in millimeters.

Time frame
Baseline and Week 24 after initial placement, before treatment procedures.
4

Mandibular anterior rotation correction

Crown-axis angular deviations of the six lower anterior teeth from the digital target setup approved before randomization, measured in the reference occlusal plane. The main indicator is mean absolute error (MAE; degrees); root mean square error (RMSE; degrees) and percentage reduction from baseline MAE are supportive indicators. Lower angular errors indicate closer agreement with the target.

Time frame
Baseline and Weeks 4, 8, 12, 16, 20 and 24 after initial placement.

Other outcomes

1

Short-term oral health-related quality of life

Arabic five-item Oral Health Impact Profile (OHIP5-Ar), with seven-day recall and a total score of 0-20. Higher scores indicate worse oral health-related quality of life. Total scores and changes from baseline are assessed regardless of whether the preceding visit included activation.

Time frame
Baseline and seven days after initial appliance placement and the Week 4, 8, 12, 16, 20 and 24 visits.
2

Orthodontic treatment impact on daily life

Arabic Orthodontic Treatment Impact Questionnaire (OTIQ-Ar): 21 scored items, with two positively worded items reverse-scored, yielding a total of 0-42. Higher scores indicate greater impact. The global question is analyzed separately on a 0-2 scale. Recall starts at initial placement for the Week 4 assessment, the Week 8 visit for the Week 12 assessment, and the Week 20 visit for the Week 24 assessment.

Time frame
Weeks 4, 12 and 24 after initial appliance placement, before treatment procedures.
3

Correlations Between Alignment Improvement and Space-Provision Measures

Exploratory correlation coefficients describing associations between the baseline-to-Week-24 reduction in Little's Irregularity Index and actual interproximal enamel reduction, changes in mandibular arch widths and anterior arch depth, and changes in lower incisor inclination and protrusion. Correlations are calculated using participant-level data.

Time frame
Changes from baseline to Week 24 after initial appliance placement.
4

Three-dimensional mandibular anterior tooth movement

Changes from baseline in crown and root-apex positions (mm), mesiodistal angulation and buccolingual inclination (degrees), and buccal/lingual root-to-cortical distances (mm), measured on cone-beam computed tomography (CBCT) images after regional registration on stable mandibular body bone. Digital intraoral scans may additionally be fused with the corresponding CBCT data to refine crown surface representation. Components are reported separately; non-assessable measurements are documented.

Time frame
Baseline and Week 24 after initial appliance placement.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

University of Aleppo

Lead sponsor

Clear Smile

Collaborator

This trial is not recruiting at the moment. You can still explore other options: