About this trial
This observational study aims to understand how electrical activity in the brain is related to activity in the stomach, heart, respiratory system, blood pressure, and glucose levels in people with drug-resistant epilepsy undergoing stereoelectroencephalography (SEEG) monitoring as part of their clinical care.
Researchers will collect synchronized recordings of brain activity and available body signals, including surface electrogastrography, electrocardiography and heart rate, abdominal respiratory movement, continuous glucose monitoring, and noninvasive blood pressure. The study will examine brain-body relationships during wakefulness, sleep, meals, seizures, and routine electrical stimulation or functional mapping performed for clinical purposes.
All decisions about SEEG implantation, electrical stimulation, functional mapping, medication, and other clinical care are made independently by the treating clinical team. The research protocol does not assign, add, or modify any electrical stimulation or treatment. The study only records and analyzes physiological responses associated with routine clinical care and naturally occurring physiological states.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age 14 to 60 years.
Diagnosis of drug-resistant epilepsy.
Selected by the clinical multidisciplinary team to undergo stereoelectroencephalography monitoring for clinical purposes.
Expected to provide analyzable data for at least one study module.
Disqualifiers
Contraindication or intolerance to the additional noninvasive physiological sensors used in the study.
Significant skin disease, infection, or injury that prevents safe placement of abdominal, electrocardiographic, continuous glucose monitoring, or blood pressure sensors.
Inability to obtain valid informed consent or assent.
Clinical judgment that research-related recording would materially interfere with necessary medical care.
Trial population
The study population consists of patients aged 14 to 60 years with drug-resistant epilepsy who are admitted to Xuanwu Hospital, Capital Medical University, for clinically indicated stereoelectroencephalography monitoring. Eligible patients will be enrolled prospectively during inpatient monitoring. Participants may contribute synchronized SEEG and available gastric, cardiac, respiratory-movement, blood pressure, and glucose data. Clinical treatment, electrode implantation, medication changes, seizure monitoring, and intracranial electrical stimulation or functional mapping are determined independently by the treating clinical team.
Trial design
Cohort
Prospective
Treatments tested in this trial
Clinically Indicated Stereoelectroencephalography Monitoring
Procedure/SurgeryParticipants undergo SEEG monitoring as part of routine clinical evaluation for drug-resistant epilepsy. The research study records and analyzes SEEG together with available gastric, cardiac, respiratory, blood pressure, and glucose signals. The decision to perform SEEG and the placement of electrodes are determined independently by the clinical care team.
Clinically Indicated Intracranial Electrical Stimulation and Functional Mapping
Procedure/SurgerySome participants may undergo intracranial electrical stimulation or functional mapping as part of routine clinical care. Stimulation targets, timing, parameters, and clinical indications are determined independently by the treating clinical team. The research protocol does not assign, add, or modify stimulation and only observes associated physiological responses.
Treatment groups
Trial outcomes
Primary outcomes
Mean Heartbeat-Evoked SEEG Potential Amplitude at 200-500 Milliseconds After the ECG R Peak
Heartbeat-evoked potentials will be measured from stereoelectroencephalography (SEEG) recordings time-locked to R peaks detected by simultaneous electrocardiography (ECG). The outcome is the mean signed potential amplitude from 200 to 500 milliseconds after the R peak, relative to the mean potential from 200 to 50 milliseconds before the R peak, expressed in microvolts (µV). Eligible heartbeats will be averaged within each segment and bipolar derivation. Derivations with prominent cardiac-field artifacts will be excluded. Results will be summarized by anatomical region and physiological state within each participant before cohort-level analysis. Pseudo-R-peak analyses will assess responses beyond chance.
Circular-Linear Correlation Coefficient Between ECG-Derived Cardiac Phase and SEEG Frequency-Band Amplitude
Cardiac phase will be derived from successive R peaks detected by electrocardiography (ECG). Neural amplitude will be derived from the Hilbert envelope of bipolar stereoelectroencephalography (SEEG) recordings in delta (1-4 Hz), theta (4-8 Hz), alpha (8-13 Hz), beta (13-30 Hz), low-gamma (30-70 Hz), and high-frequency (70-170 Hz) bands, excluding line-noise frequencies. Log-transformed amplitude will be regressed on sine and cosine of cardiac phase. The outcome is the multiple correlation coefficient R, calculated as the square root of explained variance (R²); it is dimensionless and ranges from 0 to 1. Higher values indicate stronger phase-dependent amplitude modulation. Results will be summarized by anatomical region, frequency band, and physiological state within each participant. Autocorrelation-preserving surrogates will assess coupling beyond chance.
Circular-Linear Correlation Coefficient Between Cutaneous EGG-Derived Gastric Phase and SEEG Frequency-Band Amplitude
Gastric slow-wave phase will be obtained from cutaneous electrogastrography (EGG), recorded using abdominal surface electrodes connected to the SEEG acquisition system. An individually verified gastric peak within 2-4 cycles per minute will define phase extraction. SEEG frequency-band amplitude will be obtained from bipolar recordings in delta, theta, alpha, beta, low-gamma, and high-frequency bands. Log-transformed amplitude will be regressed on sine and cosine of gastric phase. The outcome is the multiple correlation coefficient R, calculated as the square root of R²; it is dimensionless and ranges from 0 to 1. Higher values indicate stronger coupling. Results will be summarized by anatomical region, frequency band, and physiological state within each participant. Autocorrelation-preserving surrogates will assess coupling beyond chance. Segments without a verified gastric rhythm will not contribute coupling estimates.
Circular-Linear Correlation Coefficient Between Abdominal Respiratory-Movement Proxy Phase and SEEG Frequency-Band Amplitude
Respiratory-movement proxy phase will be extracted from the 0.1-0.5 Hz component of abdominal surface-electrode signals recorded by the SEEG acquisition system. This is an abdominal-movement proxy, not an independent airflow or respiratory-belt measurement. SEEG frequency-band amplitude will be obtained from bipolar recordings in delta, theta, alpha, beta, low-gamma, and high-frequency bands. Log-transformed amplitude will be regressed on sine and cosine of respiratory-proxy phase. The outcome is the multiple correlation coefficient R, calculated as the square root of R²; it is dimensionless and ranges from 0 to 1. Higher values indicate stronger coupling. Results will be summarized by anatomical region, frequency band, and physiological state within each participant. Only segments with identifiable respiratory cycles will be analyzed; autocorrelation-preserving surrogates will assess coupling beyond chance.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.