About this trial
Carotid ultrasound-based assessment of maternal hemodynamics to guide HYpertension treatment in PREgnancy - Pilot study - CHYPRE-pilot Healthy pregnancy is associated with significant physiological hemodynamic changes that are critical for maternal adaptation and health. Insufficient adaptive changes can lead to pregnancy disorders such as preeclampsia. Hypertensive disorders of pregnancy (HDP) are a leading cause of maternal and foetal morbidity and mortality. Assessment of maternal hemodynamic alterations can improve management strategies by better risk stratification of pregnant women. Current methods for maternal hemodynamic measurement involve transthoracic echocardiography, requiring expert consultation with a cardiologist and highly trained staff. Simpler techniques like carotid ultrasound based hemodynamic assessment can potentially provide an easy-to perform alternative, requiring minimal training.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Pregnant women > 18 years of age
Singleton pregnancy
10th to 40th week of pregnancy
Patients affiliated with social security or an equivalent scheme
Disqualifiers
Multifoetal pregnancy
Known allergies to ultrasound gel
Patient on AME (state medical aid)
Patient under a legal protection measure: guardianship, curatorship, or judicial safeguard.
Trial design
Single group
Treatments tested in this trial
Assessment of maternal hemodynamics
Diagnostic testCarotid ultrasound and echocardiography will be performed by an expert operator in all participants for comparison with echocardiography. In all participants, a novice operator will also perform carotid ultrasound to assess inter-operator agreement.
Treatment groups
Trial outcomes
Primary outcomes
To evaluate the accuracy of carotid-ultrasound for classifying individuals with very high peripheral vascular resistance (PVR) or not very high PVR during pregnancy, using echocardiography as the standard reference, both performed by an expert operator.
The agreement between carotid ultrasound and echocardiography to classify individuals with very high (\>1300 dynes.s.cm-5) vs not high (=\<1300 dynes.s.cm-5) PVR the day of inclusion. The area under the receiver operating characteristic (AUROC) curve, sensitivity and specificity of carotid ultrasound to identify very high PVR will be calculated.
Secondary outcomes
Evaluation of the agreement between PVR measurements obtained by echocardiography and carotid ultrasound as continuous variables.
Bland Altman analysis to evaluate the agreement between echocardiography and carotid ultrasound-based estimation of PVR on a continuous scale. Mean differences and bias will be calculated.
Evaluation of the agreement between cardiac output (CO)measurements obtained by echocardiography and carotid ultrasound as continuous variables.
Bland Altman analysis to evaluate the agreement between echocardiography and carotid ultrasound-based estimation of PVR on a continuous scale. Mean differences and bias will be calculated.
Evaluation of the inter-operator agreement and variability in carotid ultrasound measurement of PVR between an expert operator and a novice operator.
Inter-operator variability between expert and novice operator for carotid ultrasound-based PVR measurement using Bland-Altman analysis and Intraclass Correlation Coefficient (ICC) will be performed.
Evaluation of the inter-operator agreement and variability in carotid ultrasound measurement of CO between an expert operator and a novice operator.
Inter-operator variability between expert and novice operator for carotid ultrasound-based PVR measurement using Bland-Altman analysis and Intraclass Correlation Coefficient (ICC) will be performed.
Other outcomes
Evaluation of whether pregnant women with very high (>1300 dynes.s.cm-5) PVR during pregnancy (defined using carotid ultrasound) have a higher incidence of adverse pregnancy outcomes (preeclampsia or pre-term birth) compared to pregnant women without.
Single clinically adverse pregnancy outcome defined as incidence of either preeclampsia or pre-term birth - Yes/No Association with PVR tested using multivariable logistic regression.
Investigation of whether the agreement between the PVR obtained by echocardiography and carotid ultrasound is acceptable in both healthy and pathological pregnancies.
Absence of significant bias in the Bland-Altman analysis both in healthy and pathological pregnancies.
Evaluation of the usability of carotid ultrasound in routine maternity setting.
Mean group score from the post experience usability questionnaire
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Assistance Publique - Hôpitaux de Paris
Lead sponsor
Ministry of Health, France
Collaborator
This trial is not recruiting at the moment. You can still explore other options: