About this trial
The purpose of this study is to gather early and mid- to long-term evidence to confirm the clinical performance, safety and use of the Clavicle Plate and Clavicle Hook Plate System.
A minimum of 76 patients with clavicle fractures or dislocations of the AC joint surgically treated with any plate from the DPS VA-LCP Clavicle System will be enrolled in this observational post-market clinical investigation.
Outcomes will be collected until up to 2 years after surgery.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age >= 18 years
VA-LCP® Clavicle Plates 2.7: Fixation of clavicle bone fragments
VA-LCP® Clavicle Hook Plates 2.7: Fixation of lateral clavicle fractures and dislocations of the acromioclavicular joint
VA-LCP Clavicle Button Hook Plates 2.7: Fixation of acromioclavicular joint dislocations
Disqualifiers
Stable clavicle fractures
Systemic infection or infection localized to the site of the proposed implantation
Concomitant nerve or vessel injury
Polytrauma (Injury Severity Score ≥ 16)
Trial population
Any patients treated with the DPS VA-LCP® Clavicle Plate 2.7 System or the DPS VA-LCP® Clavicle Hook Plate 2.7 System for clavicular fracture or dislocations of the acromioclavicular joint
Trial design
Case-only
Prospective
Treatments tested in this trial
DPS VA-LCP® Clavicle Plate 2.7 System; DPS VA-LCP® Clavicle Hook Plate 2.7 System
DeviceThe DPS VA-LCP® Clavicle Plate 2.7 System is indicated for the fixation of clavicle bone fragments. The system consists of three plate types: lateral, shaft, and medial, each available in different sizes and materials (titanium alloy and stainless steel). Each plate is available in left and right. The DPS VA-LCP® Clavicle Clavicle Hook Plate 2.7 System is indicated or the fixation of lateral clavicle fractures and AC joint dislocations. The Clavicle Hook Plate system consists of three plate types: long, short and button plates.
Treatment groups
Trial outcomes
Primary outcomes
Safety aspects
Adverse events (AE) related or possibly related to the investigational device (ADE) or the procedure
Clinical performance
The outcome measures for clinical performance are a subcategory of safety-related parameters (e.g. incidence of complaints related to plate prominence or discomfort, fracture union rate, rate of stable AC joint healing)
Utility in terms of surgeons' experience
Surgeons satisfaction with the use and handling of the devices is evaluated in a questionnaire using 5-point Likert scale questions. These include: * Surgical time (skin to skin) required for fracture reduction and fixation * Much less time than with other implants * Slightly less time than with other implants * No difference with other implants * More time than with other implants * Much more time than with other implants * Surgeon's impression of the fitting of the device * Implant fitted well, no contouring required * Implant fitted well, minimal contouring required * Implant fitted well laterally but required contouring medially * Implant fitted well medially but required contouring laterally * Implant required contouring medially and laterally
Surgical time
Surgical time in minutes
Other outcomes
Patient characteristics
Demographics
Patient characteristics
Height in centimeters
Patient characteristics
Weight in kilograms
Patient characteristics
Body Mass Index (BMI) in kg/m\^2
Sponsors and contacts