Clinical Application of Wearable Ultrasound Sensors

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18-70
SponsorChinese PLA General Hospital

About this trial

This study aims to develop and evaluate a wearable ultrasound imaging sensor for the early diagnosis and real-time monitoring of various diseases, such as cardiovascular conditions and structural abnormalities of superficial organs. With advancements in medical technology, wearable devices have attracted increasing attention for their portability and real-time capabilities.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Age ≥ 18 yrs and able to consent

Relevant diagnosis for study arm (heart failure, lower-limb DVT, or ICU monitoring)

Adequate acoustic window and intact skin at sensor site

Heart-failure arm: Clinically stable HFrEF or HFpEF on standard therapy

Disqualifiers

Poor acoustic window preventing interpretable images

Local skin infection, open wound, or implant/hardware blocking sensor

Inability to cooperate with monitoring

Heart-failure arm: Acute MI or uncontrolled arrhythmia in past 3 months

Trial population

Participant recruitment will be conducted by licensed physicians during routine clinical follow-up.

Trial design

Design model

Other

Time perspective

Prospective

Treatments tested in this trial

  • This study is designed to assess the non-inferiority of a novel ultrasound imaging technique, rather than to evaluate a therapeutic intervention.

    Other intervention

    This study is designed to assess the non-inferiority of a novel ultrasound imaging technique, rather than to evaluate a therapeutic intervention.

Treatment groups

No treatment groups listed

Trial outcomes

Primary outcomes

1

Image Quality

* Signal-to-Noise Ratio (SNR) * Unit: decibels (dB) * Contrast-to-Noise Ratio (CNR) * Unit: decibels (dB)

Time frame
Day 1 (Baseline): Measured immediately after first wearable sensor placement
2

Image Quality

* Axial Resolution * Unit: millimeters (mm) * Lateral Resolution * Unit: millimeters (mm)

Time frame
Day 1 (Baseline): Measured immediately after first wearable sensor placement

Secondary outcomes

1

Consistency of image quality

Image Clarity Score Unit: 5-point Likert scale (1 = poor to 5 = excellent)

Time frame
Day 1 (Baseline): Measured immediately after first wearable sensor placement
2

Consistency of image quality

Intra-session Reproducibility of SNR Unit: Intraclass correlation coefficient (ICC)

Time frame
Day 1 (Baseline): Measured during the initial imaging session
3

Consistency of image quality

Diagnostic Sensitivity Unit: percent (%)

Time frame
Day 1 (Baseline): Measured during the initial imaging session

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.