Clinical Trial to Evaluate the Effectiveness of Liver Shear Wave Quantization Detector Spleen Stiffness Value in the Diagnosis of Esophageal Varices

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorBeijing Friendship Hospital

About this trial

Esophageal variceal bleeding is one of the serious and life-threatening complications of chronic liver disease (CLD). Studies have shown that the prevalence of esophageal varices (EV) in patients with liver cirrhosis is about 50%-60%. The annual incidence of variceal bleeding in these patients is about 5%-15%, and the rebleeding rate can reach 30%-40% within 6 weeks after the first bleeding. The 6-week mortality related to variceal bleeding is as high as 10%-20%, which seriously threatens the life safety of patients with liver disease. Clinically, esophagogastroduodenoscopy (EGD) is the gold standard for the diagnosis and grading of esophageal varices. However, EGD is an invasive examination, which has certain application limitations such as related complications and high cost, which limits the promotion and application of this technology.

Therefore, there is an urgent need for an accurate, convenient and non-invasive method for esophageal varices. To address this clinical pain point, Baveno VII guidelines state that spleen stiffness measurement (SSM) based on vibration-controlled transient elastography (TE) can be used as a noninvasive marker to predict esophageal varices (EV). Several studies have shown that SSM measured by TE has good diagnostic performance in relation to the occurrence and severity of esophageal varices. A study involving 191 patients with liver disease showed that spleen stiffness was significantly higher in patients with varices than in those without varices (63.69 vs 47.78 kPa, P\<0.0001), and the AUC of SSM for the diagnosis of EV was 0.74. In another study involving 260 patients with chronic liver disease, the AUC of SSM was 0.728 (95% CI: 0.665-0.791) for EV and 0.780 (95% CI: 0.714-0.846) for high-risk varix (HRV). The above results indicate that SSM has good clinical value in the prediction of EV.

Pro9000X, a liver function shear wave quantization detector based on vibration control TE, has been developed by Wuxi Hisiel Medical Technology Co., LTD. The device integrates ultrasound image positioning and TE function, aiming to achieve rapid, quantitative and non-invasive detection of liver stiffness measurement (LSM) and SSM. The results of EGD examination were used as the gold standard to evaluate the diagnostic performance of the spleen stiffness value detected by Pro9000X in patients with chronic liver disease, and the main evaluation indicators were the sensitivity and specificity of EV diagnosis. Secondary evaluation included AUROC, optimal cut-off value and diagnostic value of high-risk EV.

Eligibility criteria

Qualifiers

Age over 18 years old, male or female;

patients with clinically diagnosed chronic liver disease, including hepatitis C virus (HCV) infection, hepatitis B virus (HBV) infection, fatty liver disease, autoimmune liver disease, and alcoholic liver disease *;

Liver stiffness measurement (LSM) ≥10kPa during screening or within one month before screening [4];

able to communicate well with the investigators, understand and comply with the requirements of the study;

Disqualifiers

alanine aminotransferase (ALT) or aspartate aminotransferase (AST) ≥250 U/L;

complicated with jaundice (serum total bilirubin ≥50 μmol/L);

complicated with important organ diseases (except liver) or serious systemic diseases (such as malignant tumors and HIV);

after liver transplantation or TIPS;

Trial design

Treatments tested in this trial

  • Not listed

Trial groups

No trial groups listed

Locations

This trial has no locations

Sponsors and collaborators

Beijing Friendship Hospital

Lead sponsor

The Second Affiliated Hospital of Chongqing Medical University

Collaborator