Clinical Utility of Portable Dynamic Chest X Ray (DDR) in the ICU

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorBrigham and Women's Hospital

About this trial

Dynamic digital radiography (DDR) is a new advanced version of chest radiography that captures dynamic images at a rate of 15 frames per second. It is coupled with an analytical software that allows it to provide more advanced measures of lung motion, ventilation, and perfusion compared to traditional chest radiography. While implementation of DDR fixed machines are beginning elsewhere in the US, this trial involves the first applications of an FDA-approved portable DDR machine, for use at the bedside in the ICU.

The goal of this clinical trial is to determine the feasibility and safety of portable DDR technology in the ICU, as well as to evaluate the improved clinical diagnostic value of the portable DDR system over current standards of care.

Participants will receive one to three sets of DDR images, which will then be compared to their clinical gold standard exams (such as chest x-rays, CTs, or VQ scans) to assess and improve the precision and accuracy of measurements such as diaphragmatic motion, lung movement, and perfusion.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Adults (at least 18 years of age) including both intubated/ventilated and non-intubated patients

Likely to have pathology related to either, abnormal diaphragmatic excursion and lung aeration, pulmonary perfusion, increased lung water content or all the above, as well as for cricopharyngeal dysfunction/swallowing difficulties at risk for aspiration.

The subject or a legally authorized representative has provided written informed consent.

Disqualifiers

Special populations, including women with known pregnancy, prisoners, or institutionalized individuals

Patients where additional radiation is clinically contraindicated

Care team does not provide assent for approaching patient/surrogate

For women of child-bearing potential, defined as premenopausal women, a pregnancy test will be administered to determine pregnancy status and confirm eligibility for the study. A pregnancy test will NOT be administered to women who are post-menopausal or have documentation of surgical sterilization.

Trial design

Design model

Single group

Treatments tested in this trial

  • Portable Dynamic Digital Radiography (DDR)

    Diagnostic test

    (DDR imaging has already been described in the arm/group description). Each patient in the study will receive at least one set of DDR images, which consists of one 7-second scan in which the patient breaths normally, and a second 7-second scan in which the patient holds their breath (or for ventilated patients, an inspiratory pause is placed by the care team). If the patient's conditions warrant it, up to two sets of follow-up scans may be acquired. For instance, in a patient with diaphragmatic dysfunction, imaging may be completed pre- and post- diaphragmatic plication.

Treatment groups

230 Participants
are divided into 1 treatment group
Group A: Portable Dynamic Digital Radiography (DDR) + Clinical Gold Standard ImagingExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

I. Extended clinical trial to study the degree of precision of the Portable DDR technology in assessing the cardiopulmonary functions of diaphragm and lung motion.

Hypothesis: The Portable DDR technology can improve the visualization of parameters associated with lung physiology for ICU patients (diaphragmatic motion, lung motion) compared to current standards of care for imaging. Aim I-1: Determine the diagnostic precision of Portable DDR technology vs. routine standard of care imaging for specific lung pathologies (for example in pre- and post-transplant patients) that affect the mentioned cardiopulmonary functions. The DDR's precision will be measured by using the most relevant diagnostic procedure, the gold standard, for the condition will be used as reference to assess both qualitative and semiquantitative or quantitative information yielded by both types of imaging. The golden standard images for each of these parameters are: 1\. Diaphragmatic/Lung motion: Ultrasound imaging.

Time frame
Up to 2 months
2

II. Extended clinical trial to study the degree of precision of the Portable DDR technology in assessing the cardiopulmonary functions of pulmonary blood flow.

Hypothesis: The Portable DDR technology can improve the visualization of parameters associated with lung physiology for ICU patients (pulmonary blood flow) compared to current standards of care for imaging. Aim II-1: Determine the diagnostic precision of Portable DDR technology vs. routine standard of care imaging for specific lung pathologies (for example in pre- and post-transplant patients) that affect the mentioned cardiopulmonary function. The DDR's precision will be measured by using the most relevant diagnostic procedure, the gold standard, for the condition will be used as reference to assess both qualitative and semiquantitative or quantitative information yielded by both types of imaging. The golden standard image for this parameter is: 1\. Pulmonary blood flow: VQ scan or pulmonary angiograms The comparisons in precision for both diaphragm/lung motion and pulmonary blood flow will be aggregated to determine overall precision of the DDR technology

Time frame
Up to 2 months

Secondary outcomes

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.