Clinical Validation of an AI-Based System for Glaucoma Screening and Diagnosis

ConditionGlaucoma
Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorFondazione G.B. Bietti, IRCCS

About this trial

The GlaukomAIcare study aims to evaluate an artificial intelligence (AI)-based system designed to help identify glaucoma, an eye disease that can damage the optic nerve and cause irreversible vision loss.

The study will assess how accurately GlaukomAI identifies glaucoma compared with a diagnosis established by three glaucoma specialists using eye examinations, retinal photographs, optical coherence tomography (OCT), and visual field tests.

The study consists of two phases. The first phase will compare patients with glaucoma and healthy participants to evaluate the diagnostic accuracy of the AI system. The second phase will assess whether the system can help ophthalmologists who are not glaucoma specialists identify patients who should be referred for specialist evaluation.

Participants will undergo ophthalmological examinations and imaging assessments. All examinations will be completed during one visit or, if necessary, two consecutive visits within one week.

The results may help determine whether AI-based technology can support earlier glaucoma detection and improve referral decisions in ophthalmological practice.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Age >18 years.

Freely given informed consent obtained before study initiation.

Ability to understand and willingness to follow study instructions and likely to complete all required study visits and procedures.

Diagnosis of any type of glaucoma, including primary open-angle glaucoma, primary angle-closure glaucoma, or secondary glaucoma.

Disqualifiers

Presence of ocular media opacities preventing the acquisition of adequate-quality fundus images, including advanced cataract, vitreous hemorrhage, or severe corneal opacities.

Retinal or optic nerve diseases that could confound glaucoma diagnosis, including non-glaucomatous optic neuropathies (ischemic, inflammatory, or compressive), moderate-to-severe diabetic retinopathy, advanced age-related macular degeneration, or retinal vascular occlusions.

Any ocular surgery within the previous 3 months.

Inability to cooperate with visual field testing.

Trial design

Design model

Parallel

Treatments tested in this trial

  • Sens-vue GlaukomAI

    Device

    Sens-vue GlaukomAI is an artificial intelligence-based medical software system that analyzes pseudonymized fundus photographs to identify signs of glaucoma. In Phase 1, the software classifies images as healthy, glaucoma suspect, or glaucoma. In Phase 2, the software provides a binary referral recommendation (referable or non-referable). The investigational diagnostic and referral functions are not covered by the current Class I CE marking. The software output will be compared with an independent reference standard established by a panel of three glaucoma specialists.

Treatment groups

1,200 Participants
are divided into 3 treatment groups
Group A: Glaucoma Patients (Phase 1)Experimental treatment 1 intervention
Group B: Healthy Controls (Phase 1)Experimental treatment 1 intervention
Group C: Consecutive Ophthalmology Patients (Phase 2)Experimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Sensitivity of GlaukomAI for Glaucoma Detection

Proportion of participants with glaucoma correctly identified by GlaukomAI, compared with the reference classification established by three glaucoma specialists. Sensitivity will be expressed as a percentage with a 95% confidence interval.

Time frame
Baseline (single visit or within 1 week)
2

Specificity of GlaukomAI for Glaucoma Detection

Proportion of participants without glaucoma correctly identified by GlaukomAI, compared with the reference classification established by three glaucoma specialists. Specificity will be expressed as a percentage with a 95% confidence interval.

Time frame
Baseline (single visit or within 1 week)
3

Positive Predictive Value of GlaukomAI

Proportion of positive GlaukomAI classifications corresponding to glaucoma according to the expert reference standard. Positive predictive value will be expressed as a percentage with a 95% confidence interval.

Time frame
Baseline (single visit or within 1 week)
4

Negative Predictive Value of GlaukomAI

Proportion of negative GlaukomAI classifications corresponding to the absence of glaucoma according to the expert reference standard. Negative predictive value will be expressed as a percentage with a 95% confidence interval.

Time frame
Baseline (single visit or within 1 week)

Secondary outcomes

1

Sensitivity of GlaukomAI for Specialist Referral

Percentage of participants requiring specialist referral correctly classified as referable by GlaukomAI, compared with the reference standard established by glaucoma specialists.

Time frame
Baseline (single visit or within 1 week)
2

Specificity of GlaukomAI for Specialist Referral

Percentage of participants not requiring specialist referral correctly classified as non-referable by GlaukomAI, compared with the reference standard established by glaucoma specialists.

Time frame
Baseline (single visit or within 1 week)
3

Diagnostic Agreement Between GlaukomAI and the Expert Reference Standard

Agreement between GlaukomAI classification and the classification established by the panel of three glaucoma specialists, measured using Cohen's kappa coefficient.

Time frame
Baseline (single visit or within 1 week)
4

Referral Agreement Between Non-Specialist Ophthalmologists and the Expert Reference Standard

Agreement between referral recommendations made by non-glaucoma-specialist ophthalmologists and the reference standard established by glaucoma specialists, measured using Cohen's kappa coefficient.

Time frame
Baseline (single visit or within 1 week)

Other outcomes

Locations

This trial has no locations.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: