About this trial
The GlaukomAIcare study aims to evaluate an artificial intelligence (AI)-based system designed to help identify glaucoma, an eye disease that can damage the optic nerve and cause irreversible vision loss.
The study will assess how accurately GlaukomAI identifies glaucoma compared with a diagnosis established by three glaucoma specialists using eye examinations, retinal photographs, optical coherence tomography (OCT), and visual field tests.
The study consists of two phases. The first phase will compare patients with glaucoma and healthy participants to evaluate the diagnostic accuracy of the AI system. The second phase will assess whether the system can help ophthalmologists who are not glaucoma specialists identify patients who should be referred for specialist evaluation.
Participants will undergo ophthalmological examinations and imaging assessments. All examinations will be completed during one visit or, if necessary, two consecutive visits within one week.
The results may help determine whether AI-based technology can support earlier glaucoma detection and improve referral decisions in ophthalmological practice.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Age >18 years.
Freely given informed consent obtained before study initiation.
Ability to understand and willingness to follow study instructions and likely to complete all required study visits and procedures.
Diagnosis of any type of glaucoma, including primary open-angle glaucoma, primary angle-closure glaucoma, or secondary glaucoma.
Disqualifiers
Presence of ocular media opacities preventing the acquisition of adequate-quality fundus images, including advanced cataract, vitreous hemorrhage, or severe corneal opacities.
Retinal or optic nerve diseases that could confound glaucoma diagnosis, including non-glaucomatous optic neuropathies (ischemic, inflammatory, or compressive), moderate-to-severe diabetic retinopathy, advanced age-related macular degeneration, or retinal vascular occlusions.
Any ocular surgery within the previous 3 months.
Inability to cooperate with visual field testing.
Trial design
Parallel
Treatments tested in this trial
Sens-vue GlaukomAI
DeviceSens-vue GlaukomAI is an artificial intelligence-based medical software system that analyzes pseudonymized fundus photographs to identify signs of glaucoma. In Phase 1, the software classifies images as healthy, glaucoma suspect, or glaucoma. In Phase 2, the software provides a binary referral recommendation (referable or non-referable). The investigational diagnostic and referral functions are not covered by the current Class I CE marking. The software output will be compared with an independent reference standard established by a panel of three glaucoma specialists.
Treatment groups
Trial outcomes
Primary outcomes
Sensitivity of GlaukomAI for Glaucoma Detection
Proportion of participants with glaucoma correctly identified by GlaukomAI, compared with the reference classification established by three glaucoma specialists. Sensitivity will be expressed as a percentage with a 95% confidence interval.
Specificity of GlaukomAI for Glaucoma Detection
Proportion of participants without glaucoma correctly identified by GlaukomAI, compared with the reference classification established by three glaucoma specialists. Specificity will be expressed as a percentage with a 95% confidence interval.
Positive Predictive Value of GlaukomAI
Proportion of positive GlaukomAI classifications corresponding to glaucoma according to the expert reference standard. Positive predictive value will be expressed as a percentage with a 95% confidence interval.
Negative Predictive Value of GlaukomAI
Proportion of negative GlaukomAI classifications corresponding to the absence of glaucoma according to the expert reference standard. Negative predictive value will be expressed as a percentage with a 95% confidence interval.
Secondary outcomes
Sensitivity of GlaukomAI for Specialist Referral
Percentage of participants requiring specialist referral correctly classified as referable by GlaukomAI, compared with the reference standard established by glaucoma specialists.
Specificity of GlaukomAI for Specialist Referral
Percentage of participants not requiring specialist referral correctly classified as non-referable by GlaukomAI, compared with the reference standard established by glaucoma specialists.
Diagnostic Agreement Between GlaukomAI and the Expert Reference Standard
Agreement between GlaukomAI classification and the classification established by the panel of three glaucoma specialists, measured using Cohen's kappa coefficient.
Referral Agreement Between Non-Specialist Ophthalmologists and the Expert Reference Standard
Agreement between referral recommendations made by non-glaucoma-specialist ophthalmologists and the reference standard established by glaucoma specialists, measured using Cohen's kappa coefficient.
Locations
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: