About this trial
The purpose of this study is to evaluate the clinical value of mobile 4D CBCT technology in the diagnosis and treatment of peripheral pulmonary lesions and to validate its intraoperative dynamic three-dimensional CT imaging capability.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age >18 years old.
Patients whose chest CT scans indicate the presence of peripheral pulmonary lesions and require further diagnosis via transbronchial lung biopsy (TBLB).
Lesion size: 8 mm < longest diameter of lesion ≤ 50 mm.
Understands the study and has provided signed informed consent.
Disqualifiers
Contraindications to bronchoscopy are present.
Severe cardiopulmonary dysfunction or other conditions that may increase surgical risk.
The investigator considers that the patient has other conditions which make them unsuitable for participation in this study.
Trial population
Patients who underwent mobile CBCT scanning.
Trial design
Other
Prospective
Treatments tested in this trial
Mobile CBCT Three-Dimensional Scanning
RadiationMobile CBCT Three-Dimensional Scanning
Treatment groups
Trial outcomes
Primary outcomes
RMSE(Root Mean Squared Error)
RMSE (Root Mean Square Error): A commonly used metric for measuring the difference between predicted values and actual values. It is applicable in regression problems and image quality assessment. A smaller RMSE value indicates more accurate predictions, with 0 representing perfect accuracy, while a larger value indicates greater error.
SSIM (Structural Similarity )
SSIM (Structural Similarity ): A metric used to measure the similarity between two images, comparing them across three dimensions: luminance, contrast, and structure. The SSIM value ranges from \[-1, 1\], where 1 indicates that the two images are identical, and 0 or negative values indicate complete dissimilarity.
Secondary outcomes
Image Quality
Three experienced experts scored the three-dimensional CT reconstruction images based on image quality using the following criteria:4 points: Exceptionally clear images;3 points: Generally clear images with a few blurred slices;2 points: Basically clear images but with several blurred slices;1 point: Unclear images.
Slice Continuity
Three experienced experts scored the three-dimensional CT reconstruction images based on slice continuity using the following criteria:4 points: All slices exhibit continuous anatomical structures;3 points: Overall continuous with minor discontinuities in a few slices;2 points: Generally continuous but with noticeable discontinuities in multiple slices;1 point: Predominantly discontinuous across most slices.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: